메뉴 건너뛰기




Volumn 44, Issue 2, 1998, Pages 368-371

Mechanical performance of an axially mobile plate for fracture fixation

Author keywords

Axially mobile; Bone plate; Fracture fixation; Mechanical tests

Indexed keywords

BIOMECHANICS; BONE PLATE; BONE REMODELING; CONFERENCE PAPER; FRACTURE; FRACTURE FIXATION; FRACTURE HEALING; PRIORITY JOURNAL;

EID: 0031939396     PISSN: 00225282     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005373-199802000-00024     Document Type: Conference Paper
Times cited : (4)

References (24)
  • 1
    • 0021352740 scopus 로고
    • The role of rigidity in fracture fixation: An overview
    • Uhthoff HK, Finnegan MA. The role of rigidity in fracture fixation: an overview. Arch Orthop Trauma Surg. 1984; 102:163.
    • (1984) Arch Orthop Trauma Surg , vol.102 , pp. 163
    • Uhthoff, H.K.1    Finnegan, M.A.2
  • 2
    • 0345587637 scopus 로고
    • Flexible versus nonflexible fracture fixation
    • Lane JM, ed. London: Churchill Livingstone
    • Brown SA, Gillett NA, Broaddus TW. Flexible versus nonflexible fracture fixation. In: Lane JM, ed. Fracture Healing. London: Churchill Livingstone; 1987:191-202.
    • (1987) Fracture Healing , pp. 191-202
    • Brown, S.A.1    Gillett, N.A.2    Broaddus, T.W.3
  • 3
    • 0016164585 scopus 로고
    • Tibial blood supply in relation to fracture healing
    • Rhinelander FW. Tibial blood supply in relation to fracture healing. Clin Orthop. 1974;150:34-81.
    • (1974) Clin Orthop , vol.150 , pp. 34-81
    • Rhinelander, F.W.1
  • 4
    • 0025454632 scopus 로고
    • Structural and biomechanical changes in bone after rigid plate fixation
    • Smith SR, Bronk JT, Kelly PJ. Structural and biomechanical changes in bone after rigid plate fixation. J Orthop Res. 1990;8(4):471-478.
    • (1990) J Orthop Res , vol.8 , Issue.4 , pp. 471-478
    • Smith, S.R.1    Bronk, J.T.2    Kelly, P.J.3
  • 6
    • 0022413393 scopus 로고
    • The influence of induced micromovement upon the healing of experimental tibial fractures
    • Goodship AE, Kenwright J. The influence of induced micromovement upon the healing of experimental tibial fractures. J Bone Joint Surg Br. 1985;67:650.
    • (1985) J Bone Joint Surg Br , vol.67 , pp. 650
    • Goodship, A.E.1    Kenwright, J.2
  • 7
    • 0023039370 scopus 로고
    • Effect of controlled axial micromovement on healing of tibial fracture
    • Kenwright J, Richardson JB, Goodship AE, et al. Effect of controlled axial micromovement on healing of tibial fracture. Lancet. 1986;2:1185.
    • (1986) Lancet , vol.2 , pp. 1185
    • Kenwright, J.1    Richardson, J.B.2    Goodship, A.E.3
  • 8
    • 0027467108 scopus 로고
    • Effects of instability on bone healing: Femoral osteotomies studied in rats
    • Grundnes O, Reikeras O. Effects of instability on bone healing: femoral osteotomies studied in rats. Acta Orthop Scand. 1993;641:55.
    • (1993) Acta Orthop Scand , vol.641 , pp. 55
    • Grundnes, O.1    Reikeras, O.2
  • 9
    • 0019409452 scopus 로고
    • The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures
    • Uhthoff HK, Bardos DI, Liskoka-Kiar M. The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures. J Bone Joint Surg Br. 1981;63:427.
    • (1981) J Bone Joint Surg Br , vol.63 , pp. 427
    • Uhthoff, H.K.1    Bardos, D.I.2    Liskoka-Kiar, M.3
  • 10
    • 0019982649 scopus 로고
    • The use of semi-rigid carbon-fibre-reinforced plastic plates for fixation of human fractures
    • Tayton K, Johnson C, Mckibbin B, Bradley J, Hastings G. The use of semi-rigid carbon-fibre-reinforced plastic plates for fixation of human fractures. J Bone Joint Surg Br. 1982; 64:105.
    • (1982) J Bone Joint Surg Br , vol.64 , pp. 105
    • Tayton, K.1    Johnson, C.2    Mckibbin, B.3    Bradley, J.4    Hastings, G.5
  • 11
    • 0018762030 scopus 로고
    • Physical and biological aspects of fracture healing with special reference to internal fixation
    • Perrn SM. Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop. 1979;138:175.
    • (1979) Clin Orthop , vol.138 , pp. 175
    • Perrn, S.M.1
  • 12
    • 0024245790 scopus 로고
    • The effects of function and fixation stiffness on experimental bone healing
    • Terjesen T, Svenningsen S. The effects of function and fixation stiffness on experimental bone healing. Acta Orthop Scand. 1988;59:712.
    • (1988) Acta Orthop Scand , vol.59 , pp. 712
    • Terjesen, T.1    Svenningsen, S.2
  • 13
    • 0026333014 scopus 로고
    • The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP): Scientific background, design and application
    • Perren SM. The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP): scientific background, design and application. Injury. 1991; 22(suppl 1):1.
    • (1991) Injury , vol.22 , Issue.1 SUPPL. , pp. 1
    • Perren, S.M.1
  • 15
    • 0024544662 scopus 로고
    • Controlled mechanical stimulation in the treatment of tibial fractures
    • Kenwright J, Goodship AE. Controlled mechanical stimulation in the treatment of tibial fractures. Clin Orthop. 1989;241:36.
    • (1989) Clin Orthop , vol.241 , pp. 36
    • Kenwright, J.1    Goodship, A.E.2
  • 16
    • 0025807515 scopus 로고
    • Axial movement and tibial fractures: A controlled randomised trial of treatment
    • Kenwright J, Richardson JB, Cuningham JL, et al. Axial movement and tibial fractures: A controlled randomised trial of treatment. J Bone Joint Surg Br. 1991;73:654.
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 654
    • Kenwright, J.1    Richardson, J.B.2    Cuningham, J.L.3
  • 17
    • 0027179770 scopus 로고
    • Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression
    • Aro HT, Chao EYS. Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression. Clin Orthop. 1993;293:8.
    • (1993) Clin Orthop , vol.293 , pp. 8
    • Aro, H.T.1    Chao, E.Y.S.2
  • 18
    • 0021192354 scopus 로고
    • Less rigid internal fixation plates: Historical perspectives and new concepts
    • Woo SLY, Lothringer KS, Akeson WH, et al. Less rigid internal fixation plates: historical perspectives and new concepts. J Orthop Res. 1984;1:431.
    • (1984) J Orthop Res , vol.1 , pp. 431
    • Woo, S.L.Y.1    Lothringer, K.S.2    Akeson, W.H.3
  • 19
    • 0005576235 scopus 로고
    • Axially flexible (AF) bone plates improve healing by 40% in one third the time: An experimental study in dogs
    • Paris, France, April 19-20
    • Uhthoff HK, Foux A, Yeadon A, McAuley J. Axially flexible (AF) bone plates improve healing by 40% in one third the time: an experimental study in dogs. Paper presented at the Third Conference of the European Orthopaedic Research Society, Paris, France, April 19-20, 1993.
    • (1993) Third Conference of the European Orthopaedic Research Society
    • Uhthoff, H.K.1    Foux, A.2    Yeadon, A.3    McAuley, J.4
  • 20
    • 0020029438 scopus 로고
    • The mechanical performance of the standard Hoffmann-Vidal external fixation apparatus
    • Briggs BT, Chao EYS. The mechanical performance of the standard Hoffmann-Vidal external fixation apparatus. J Bone Joint Surg Am. 1982;64:566.
    • (1982) J Bone Joint Surg Am , vol.64 , pp. 566
    • Briggs, B.T.1    Chao, E.Y.S.2
  • 21
    • 0024010118 scopus 로고
    • Stability of the original Hoffmann and AO tubular external fixation devices
    • Moroz TK, Finlay JB, Rorabeck CH, Bourne RB. Stability of the original Hoffmann and AO tubular external fixation devices. Med Biol Eng Comput. 1988;26:271.
    • (1988) Med Biol Eng Comput , vol.26 , pp. 271
    • Moroz, T.K.1    Finlay, J.B.2    Ch, R.3    Bourne, R.B.4
  • 22
    • 0024516018 scopus 로고
    • A biomechanical analysis of the Ilizarov external fixator
    • Fleming B, Paley D, Kristiansen T, Pope M. A biomechanical analysis of the Ilizarov external fixator. Clin Orthop. 1989;241:95.
    • (1989) Clin Orthop , vol.241 , pp. 95
    • Fleming, B.1    Paley, D.2    Kristiansen, T.3    Pope, M.4
  • 23
    • 0025322465 scopus 로고
    • Performance of external fixation devices in femoral fractures: The ultimate challenge?
    • Broekhuizen AH, Boxma H, Meulen PA, Snijders CJ. Performance of external fixation devices in femoral fractures: the ultimate challenge? Injury. 1990;21:145.
    • (1990) Injury , vol.21 , pp. 145
    • Broekhuizen, A.H.1    Boxma, H.2    Meulen, P.A.3    Snijders, C.J.4
  • 24
    • 0026738517 scopus 로고
    • Universal joint slippage as a cause of Hoffmann half-frame external fixator failure
    • Drijber FLIP, Finlay JB. Universal joint slippage as a cause of Hoffmann half-frame external fixator failure. J Biomed Eng. 1992;14:509.
    • (1992) J Biomed Eng , vol.14 , pp. 509
    • Drijber, F.L.I.P.1    Finlay, J.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.