메뉴 건너뛰기




Volumn 29, Issue 2, 1998, Pages 140-143

Late hypotony after cataract extraction due to a scleral fistula: A technique for surgical correction

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CASE REPORT; CATARACT; FISTULA; HUMAN; INTRAOCULAR PRESSURE; INTRAOCULAR PRESSURE ABNORMALITY; MALE; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; SCLERA; SURGICAL TECHNIQUE;

EID: 0031937061     PISSN: 10823069     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (15)
  • 1
    • 0014977874 scopus 로고
    • Management of persistent hypotony after planned or inadvertent cyclodialysis
    • Maumenee AK, Stark WJ. Management of persistent hypotony after planned or inadvertent cyclodialysis. Am J Ophthalmol. 1971;71:320-327.
    • (1971) Am J Ophthalmol , vol.71 , pp. 320-327
    • Maumenee, A.K.1    Stark, W.J.2
  • 2
    • 0030247704 scopus 로고    scopus 로고
    • Postsurgical hypotony: Relationship to fistulization, inflammation, chorioretinal lesions, and the vitreous
    • Schubert HD. Postsurgical hypotony: relationship to fistulization, inflammation, chorioretinal lesions, and the vitreous. Surv Ophthalmol. 1996;41:97-126.
    • (1996) Surv Ophthalmol , vol.41 , pp. 97-126
    • Schubert, H.D.1
  • 4
    • 0023930591 scopus 로고
    • Fistula excision and peripheral grafts in the treatment of persistent limbal wound leaks
    • Soong HK, Meyer RF, Wolter JR. Fistula excision and peripheral grafts in the treatment of persistent limbal wound leaks. Ophthalmology. 1988;95:31-36.
    • (1988) Ophthalmology , vol.95 , pp. 31-36
    • Soong, H.K.1    Meyer, R.F.2    Wolter, J.R.3
  • 5
    • 0026443741 scopus 로고
    • Repair of inadvertent conjunctival filtering blebs with a scleral flap
    • Clinch TE, Kaufman HE. Repair of inadvertent conjunctival filtering blebs with a scleral flap. Arch Ophthalmol. 1992;110:1652-1653.
    • (1992) Arch Ophthalmol , vol.110 , pp. 1652-1653
    • Clinch, T.E.1    Kaufman, H.E.2
  • 6
    • 0020793726 scopus 로고
    • Hypotony as a late complication of extracapsular cataract extraction
    • Geyer O, Godel V, Lazar M. Hypotony as a late complication of extracapsular cataract extraction. Am J Ophthalmol. 1983;96:112-113.
    • (1983) Am J Ophthalmol , vol.96 , pp. 112-113
    • Geyer, O.1    Godel, V.2    Lazar, M.3
  • 9
    • 0019464087 scopus 로고
    • A simple method of repairing inadvertent filtering blebs after cataract surgery
    • Bruner WE, Maumenee AK, Stark WJ. A simple method of repairing inadvertent filtering blebs after cataract surgery. Am J Ophthalmol. 1981;91:794-796.
    • (1981) Am J Ophthalmol , vol.91 , pp. 794-796
    • Bruner, W.E.1    Maumenee, A.K.2    Stark, W.J.3
  • 10
    • 0015815848 scopus 로고
    • Cauterization of filtering blebs following cataract extraction
    • Kirk HQ. Cauterization of filtering blebs following cataract extraction. Trans Am Acad Ophthalmol Otolaryngol. 1973;77:573.
    • (1973) Trans Am Acad Ophthalmol Otolaryngol , vol.77 , pp. 573
    • Kirk, H.Q.1
  • 11
    • 0015367029 scopus 로고
    • Cystoid bleb cryotherapy
    • Douvas NG. Cystoid bleb cryotherapy. Am J Ophthalmol. 1972;74:69-71.
    • (1972) Am J Ophthalmol , vol.74 , pp. 69-71
    • Douvas, N.G.1
  • 12
    • 0031004849 scopus 로고    scopus 로고
    • The use of processes pericardium in the repair of corneo-scleral fistulas
    • Sibayan SAB, Latina MA. The use of processes pericardium in the repair of corneo-scleral fistulas. Ophthalmic Surg Lasers. 1997;28:334-335.
    • (1997) Ophthalmic Surg Lasers , vol.28 , pp. 334-335
    • Sibayan, S.A.B.1    Latina, M.A.2
  • 13
    • 0019366126 scopus 로고
    • Ciliary body reattachment in ocular hypotony
    • Shea M, Mednick EB. Ciliary body reattachment in ocular hypotony. Arch Ophthalmol. 1981;99:278.
    • (1981) Arch Ophthalmol , vol.99 , pp. 278
    • Shea, M.1    Mednick, E.B.2
  • 14
    • 0023863330 scopus 로고
    • Surgical management of ocular hypotony
    • Demeler U. Surgical management of ocular hypotony. Eye. 1988;2:77-79.
    • (1988) Eye , vol.2 , pp. 77-79
    • Demeler, U.1
  • 15
    • 0025744660 scopus 로고
    • Reattachment of the detached ciliary body with suturing for treatment of contusional ocular hypotension
    • Zheng Y, Ji X. Reattachment of the detached ciliary body with suturing for treatment of contusional ocular hypotension. Ophthalmic Surg. 1991;22:360-362.
    • (1991) Ophthalmic Surg , vol.22 , pp. 360-362
    • Zheng, Y.1    Ji, X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.