메뉴 건너뛰기




Volumn 7, Issue 1, 1998, Pages 72-74

Application of cyanoacrylate adhesive (Krazy G13lue) in critical cardiac injuries

Author keywords

[No Author keywords available]

Indexed keywords

CYANOACRYLATE; TISSUE ADHESIVE;

EID: 0031932156     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (13)
  • 1
    • 0027395456 scopus 로고
    • Subacute cardiac rupture: Repair with a sutureless technique
    • Padro JM, Mesa JM, Silvestre J. Subacute cardiac rupture: Repair with a sutureless technique. Ann Thorac Surg 1993:55:20-24
    • (1993) Ann Thorac Surg , vol.55 , pp. 20-24
    • Padro, J.M.1    Mesa, J.M.2    Silvestre, J.3
  • 2
    • 0028239821 scopus 로고
    • The use of cyanoacrylate adhesive (Krazy Glue) in cardiac surgery
    • Robicsek FR, Reilly JP, Marroum MC. The use of cyanoacrylate adhesive (Krazy Glue) in cardiac surgery. J Card Surg 1994;9(3):353-356
    • (1994) J Card Surg , vol.9 , Issue.3 , pp. 353-356
    • Robicsek, F.R.1    Reilly, J.P.2    Marroum, M.C.3
  • 3
    • 0029981330 scopus 로고    scopus 로고
    • Use of cyanoacrylate tissue adhesive in small incision cataract surgery
    • Alio JL, Mulet ME, Garcia JC. Use of cyanoacrylate tissue adhesive in small incision cataract surgery. Ophthal Usrg Lasers, 1996;27(4):270-274
    • (1996) Ophthal Usrg Lasers , vol.27 , Issue.4 , pp. 270-274
    • Alio, J.L.1    Mulet, M.E.2    Garcia, J.C.3
  • 5
    • 0029957334 scopus 로고    scopus 로고
    • Meniscal repair. Where do we go from here?
    • Kollias SL, Fox JM. Meniscal repair. Where do we go from here? Clin Sports Med 1996;15(3):621-630
    • (1996) Clin Sports Med , vol.15 , Issue.3 , pp. 621-630
    • Kollias, S.L.1    Fox, J.M.2
  • 6
    • 0030124501 scopus 로고    scopus 로고
    • Viability of split-thickness skin grafts attached with fibrin glue
    • Schumacher J, Ford TS, Brumbaugh GW, Honnas CM. Viability of split-thickness skin grafts attached with fibrin glue. Can J Vet Res 1996;60(2):158-160
    • (1996) Can J Vet Res , vol.60 , Issue.2 , pp. 158-160
    • Schumacher, J.1    Ford, T.S.2    Brumbaugh, G.W.3    Honnas, C.M.4
  • 8
    • 0031149551 scopus 로고    scopus 로고
    • Management of the uncontrollable pulmonary air leak with cyanoacrylate glue
    • Horsley WS, Miller JI. Management of the uncontrollable pulmonary air leak with cyanoacrylate glue. Ann Thorac Surg 1997;63:1492-1493
    • (1997) Ann Thorac Surg , vol.63 , pp. 1492-1493
    • Horsley, W.S.1    Miller, J.I.2
  • 9
    • 0030462658 scopus 로고    scopus 로고
    • Subacute left ventricular free wall rupture complicating acute myocardial infarction
    • Lijoi A, Scarano F, Parodi E, et al. Subacute left ventricular free wall rupture complicating acute myocardial infarction. J Cardiovasc Surg 1996;37:627-630
    • (1996) J Cardiovasc Surg , vol.37 , pp. 627-630
    • Lijoi, A.1    Scarano, F.2    Parodi, E.3
  • 10
    • 0005775587 scopus 로고
    • The degradation of cyanoacrylate tissue adhesive
    • Cameron JL, Woodward SC, Pulaski EJ, et al. The degradation of cyanoacrylate tissue adhesive. Surgery 1963:58:424-430
    • (1963) Surgery , vol.58 , pp. 424-430
    • Cameron, J.L.1    Woodward, S.C.2    Pulaski, E.J.3
  • 12
    • 0024677262 scopus 로고
    • Cytotoxicity of akyl-2-cyanoacrylate adhesives
    • Papatheofanis FJ. Cytotoxicity of akyl-2-cyanoacrylate adhesives. J Biomed Mater Res 1989;23:661-668
    • (1989) J Biomed Mater Res , vol.23 , pp. 661-668
    • Papatheofanis, F.J.1
  • 13
    • 0023848821 scopus 로고
    • Endoscopic closure of bronchopleural fistulas using a tissue adhesive
    • Menard JW, Prejean CA, Tucker WY. Endoscopic closure of bronchopleural fistulas using a tissue adhesive. Am J Surg 1988;155:415-416
    • (1988) Am J Surg , vol.155 , pp. 415-416
    • Menard, J.W.1    Prejean, C.A.2    Tucker, W.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.