메뉴 건너뛰기




Volumn 135, Issue 1, 1998, Pages 152-156

Hemostasis success rates and local complications with collagen after femoral access for cardiac catheterization: Analysis of 6007 published patients

Author keywords

[No Author keywords available]

Indexed keywords

COLLAGEN;

EID: 0031930499     PISSN: 00028703     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-8703(98)70356-4     Document Type: Article
Times cited : (72)

References (39)
  • 1
    • 0013692509 scopus 로고
    • Immediate sealing of arterial puncture sites after catheterization and PTCA using a vascular hemostasis device with collagen: an international registry
    • J Ernst R Kloss R Schraeder M Kaltenbach U Sigwart TA Sanborn Immediate sealing of arterial puncture sites after catheterization and PTCA using a vascular hemostasis device with collagen: an international registry Circulation 84 1991 I272
    • (1991) Circulation , vol.84 , pp. I272
    • Ernst, J1    Kloss, R2    Schraeder, R3    Kaltenbach, M4    Sigwart, U5    Sanborn, TA6
  • 2
    • 0002850227 scopus 로고
    • Reduced compression time using a vascular hemostasis device after diagnostic angiography and angioplasty: a multi-center randomized trial
    • TA Sanborn JA Brinker EJ Kosinski WD Knopf Reduced compression time using a vascular hemostasis device after diagnostic angiography and angioplasty: a multi-center randomized trial Circulation 86 1992 I1483
    • (1992) Circulation , vol.86 , pp. I1483
    • Sanborn, TA1    Brinker, JA2    Kosinski, EJ3    Knopf, WD4
  • 3
    • 0027361507 scopus 로고
    • A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty
    • TA Sanborn HH Gibbs JA Brinker WA Knopf EJ Kosinski GS Roubin A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty J Am Coll Cardiol 22 1993 1273 1279
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1273-1279
    • Sanborn, TA1    Gibbs, HH2    Brinker, JA3    Knopf, WA4    Kosinski, EJ5    Roubin, GS6
  • 4
    • 0028929625 scopus 로고
    • A single center randomized trial assessing use of a vascular hemostasis device vs conventional manual compression following PTCA: what are the potential resource savings?
    • PM Slaughter R Chetty VF Flintoft S Lewis K Sykora DM Beattie A single center randomized trial assessing use of a vascular hemostasis device vs conventional manual compression following PTCA: what are the potential resource savings? Cathet Cardiovasc Diagn 34 1995 210 214
    • (1995) Cathet Cardiovasc Diagn , vol.34 , pp. 210-214
    • Slaughter, PM1    Chetty, R2    Flintoft, VF3    Lewis, S4    Sykora, K5    Beattie, DM6
  • 5
    • 0027399462 scopus 로고
    • Immediate sealing of arterial puncture sites after cardiac catheterization and coronary angioplasty using a biodegradable collagen plug: results of an international registry
    • SMPG Ernst RM Tjonjoegin R Schräder M Kaltenbach U Sigwart TA Sanborn Immediate sealing of arterial puncture sites after cardiac catheterization and coronary angioplasty using a biodegradable collagen plug: results of an international registry J Am Coll Cardiol 21 1993 851 855
    • (1993) J Am Coll Cardiol , vol.21 , pp. 851-855
    • Ernst, SMPG1    Tjonjoegin, RM2    Schräder, R3    Kaltenbach, M4    Sigwart, U5    Sanborn, TA6
  • 6
    • 0027175065 scopus 로고
    • Early mobilisation after percutaneous cardiac catheterisation using collagen plug (VasoSeal) haemostasis
    • JPM Foran D Patel J Brookes Wainwright Early mobilisation after percutaneous cardiac catheterisation using collagen plug (VasoSeal) haemostasis Br Heart J 69 1993 424 429
    • (1993) Br Heart J , vol.69 , pp. 424-429
    • Foran, JPM1    Patel, D2    Brookes, J3    Wainwright4
  • 7
    • 0027425935 scopus 로고
    • Collagen plug hemostatic closure of femoral arterial puncture sites following implantation of intracoronary stents
    • JG Webb RA Carere AA Dodek Collagen plug hemostatic closure of femoral arterial puncture sites following implantation of intracoronary stents Cathet Cardiovasc Diagn 30 1993 314 316
    • (1993) Cathet Cardiovasc Diagn , vol.30 , pp. 314-316
    • Webb, JG1    Carere, RA2    Dodek, AA3
  • 8
    • 0029019407 scopus 로고
    • Prompt and safe femoral hemostasis with a collagen device after intracoronary implantation of Palmaz-Schatz stents
    • AL Bartorelli P Sganzerla F Fabbiocchi P Montorsi N De Cesare M Child Prompt and safe femoral hemostasis with a collagen device after intracoronary implantation of Palmaz-Schatz stents Am Heart J 130 1995 26 32
    • (1995) Am Heart J , vol.130 , pp. 26-32
    • Bartorelli, AL1    Sganzerla, P2    Fabbiocchi, F3    Montorsi, P4    De Cesare, N5    Child, M6
  • 9
    • 0029034865 scopus 로고
    • Rapid arterial hemostasis and decreased access site complications after cardiac catheterization and angioplasty: results of a randomized trial of a novel hemostatic device
    • WG Kussmaul III M Buchbinder PL Whitlow UT Aker RR Heuser SB King Rapid arterial hemostasis and decreased access site complications after cardiac catheterization and angioplasty: results of a randomized trial of a novel hemostatic device J Am Coll Cardiol 25 1995 1685 1692
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1685-1692
    • Kussmaul, WG1    Buchbinder, M2    Whitlow, PL3    Aker, UT4    Heuser, RR5    King, SB6
  • 10
    • 0031043073 scopus 로고    scopus 로고
    • Use of a collagen plug versus manual compression for sealing arterial puncture site after cardiac catheterization
    • M Gwechenberger R Katzenschlager G Heinz M Gottsauner-Wolf P Probst Use of a collagen plug versus manual compression for sealing arterial puncture site after cardiac catheterization Angiology 48 1997 121 126
    • (1997) Angiology , vol.48 , pp. 121-126
    • Gwechenberger, M1    Katzenschlager, R2    Heinz, G3    Gottsauner-Wolf, M4    Probst, P5
  • 11
    • 0016816307 scopus 로고
    • The effectiveness and mechanism of collagen-induced topical hemostasis
    • WM Abbott WG Austen The effectiveness and mechanism of collagen-induced topical hemostasis Surgery 78 1975 723 729
    • (1975) Surgery , vol.78 , pp. 723-729
    • Abbott, WM1    Austen, WG2
  • 12
    • 0011723757 scopus 로고
    • Use of tanned collagen sponges in the treatment of liver injuries
    • E Peacock H Siegler P Biggers Use of tanned collagen sponges in the treatment of liver injuries Ann Surg 161 1965 238 243
    • (1965) Ann Surg , vol.161 , pp. 238-243
    • Peacock, E1    Siegler, H2    Biggers, P3
  • 13
    • 0019449208 scopus 로고
    • Experimental and clinical experiences with collagen fleece as a hemostatic agent
    • ME Silverstein M Chvapil Experimental and clinical experiences with collagen fleece as a hemostatic agent J Trauma 21 1981 388 393
    • (1981) J Trauma , vol.21 , pp. 388-393
    • Silverstein, ME1    Chvapil, M2
  • 14
    • 0025000939 scopus 로고
    • Effect of hemostatic fleece on 14C-Serotonin release by human platelets
    • M Chvapil H Holubec Effect of hemostatic fleece on 14C-Serotonin release by human platelets Jpn Pharmacol Ther 18 1990 57(2913) 62(2918)
    • (1990) Jpn Pharmacol Ther , vol.18 , pp. 57(2913)-62(2918)
    • Chvapil, M1    Holubec, H2
  • 15
    • 0027218804 scopus 로고
    • A new hemostatic puncture closure device for the immediate sealing of arterial puncture sites
    • H de Swart L Dijkman L Hofstra FW Bär V Van Ommen J Tordoir A new hemostatic puncture closure device for the immediate sealing of arterial puncture sites Am J Cardiol 72 1993 445 449
    • (1993) Am J Cardiol , vol.72 , pp. 445-449
    • de Swart, H1    Dijkman, L2    Hofstra, L3    Bär, FW4    Van Ommen, V5    Tordoir, J6
  • 17
    • 0029347753 scopus 로고
    • A new access site management tool: the Angio-Seal hemostatic puncture closure device
    • M Henry M Amor M Allaoui O Tricoche A new access site management tool: the Angio-Seal hemostatic puncture closure device J Endovasc Surg 2 1995 289 296
    • (1995) J Endovasc Surg , vol.2 , pp. 289-296
    • Henry, M1    Amor, M2    Allaoui, M3    Tricoche, O4
  • 18
    • 0006876838 scopus 로고
    • Intra-arterial anchoring is superior to plain collagen plugging for sealing arterial puncture sites and ambulating after 20 minutes
    • S Silber C Luckas R Dörr H Mühling G Zindler Intra-arterial anchoring is superior to plain collagen plugging for sealing arterial puncture sites and ambulating after 20 minutes Circulation 92 1995 I-225
    • (1995) Circulation , vol.92 , pp. I-225
    • Silber, S1    Luckas, C2    Dörr, R3    Mühling, H4    Zindler, G5
  • 20
    • 0028213486 scopus 로고
    • Immediate arterial hemostasis after cardiac catheterization: Initial experience with a new puncture closure device
    • UT Aker KR Kensey RR Heuser JG Sandza WG Kussmaul III Immediate arterial hemostasis after cardiac catheterization: Initial experience with a new puncture closure device Cathet Cardiovasc Diagn 31 1994 228 232
    • (1994) Cathet Cardiovasc Diagn , vol.31 , pp. 228-232
    • Aker, UT1    Kensey, KR2    Heuser, RR3    Sandza, JG4    Kussmaul, WG5
  • 21
    • 0002606538 scopus 로고
    • Hemostatic puncture closure device versus regular compression: a randomized study
    • B Chevalier B Lancelin X Berthaux Hemostatic puncture closure device versus regular compression: a randomized study J Am Coll Cardiol 23 1995 93A
    • (1995) J Am Coll Cardiol , vol.23 , pp. 93A
    • Chevalier, B1    Lancelin, B2    Berthaux, X3
  • 22
    • 0027248902 scopus 로고
    • Frühzeitige Blutsstillung nach koronartherapeutischen Eingriffen durch Anwendung von Kollagenplugs
    • C Kühn D Sümpelmann B Geiger R Siems KP Kunze M Geiger Frühzeitige Blutsstillung nach koronartherapeutischen Eingriffen durch Anwendung von Kollagenplugs Z Kardiol 82 1993 515 520
    • (1993) Z Kardiol , vol.82 , pp. 515-520
    • Kühn, C1    Sümpelmann, D2    Geiger, B3    Siems, R4    Kunze, KP5    Geiger, M6
  • 23
    • 0342684437 scopus 로고    scopus 로고
    • Sheath pulling immediately after PTCA: comparison of two different deployment techniques for the hemostatic puncture closure device. A prospective, randomized study
    • S Silber R Dörr H Mühling U König Sheath pulling immediately after PTCA: comparison of two different deployment techniques for the hemostatic puncture closure device. A prospective, randomized study Cathet Cardiovasc Diagn 41 1997 378 383
    • (1997) Cathet Cardiovasc Diagn , vol.41 , pp. 378-383
    • Silber, S1    Dörr, R2    Mühling, H3    König, U4
  • 24
    • 0003890450 scopus 로고
    • Advantages of sealing arterial puncture sites after PTCA with a single collagen plug: a randomized, prospective trial
    • S Silber A Björvik A Rösch H Mühling Advantages of sealing arterial puncture sites after PTCA with a single collagen plug: a randomized, prospective trial J Am Coll Cardiol 23 1995 262A
    • (1995) J Am Coll Cardiol , vol.23 , pp. 262A
    • Silber, S1    Björvik, A2    Rösch, A3    Mühling, H4
  • 25
    • 0013673316 scopus 로고
    • Early ambulation (30 minutes) after cardiac catheterization using the collagen plug. Efficacy and follow-up comparing two different plug dosages in 660 cases
    • S Silber C Haentsch N Seidel H Mühling Early ambulation (30 minutes) after cardiac catheterization using the collagen plug. Efficacy and follow-up comparing two different plug dosages in 660 cases J Am Coll Cardiol 21 1993 150A
    • (1993) J Am Coll Cardiol , vol.21 , pp. 150A
    • Silber, S1    Haentsch, C2    Seidel, N3    Mühling, H4
  • 26
    • 0028022156 scopus 로고
    • Collagen application versus manual compression: a prospective randomized trial for arterial puncture site closure after coronary angioplasty
    • E Camenzind M Grossholz P Urban PA Dorsaz D Didier B Meier Collagen application versus manual compression: a prospective randomized trial for arterial puncture site closure after coronary angioplasty J Am Coll Cardiol 24 1994 655 662
    • (1994) J Am Coll Cardiol , vol.24 , pp. 655-662
    • Camenzind, E1    Grossholz, M2    Urban, P3    Dorsaz, PA4    Didier, D5    Meier, B6
  • 27
    • 0026475648 scopus 로고
    • Collagen application for sealing of arterial puncture sites in comparison to pressure dressing: a randomized trial
    • R Schräder S Steinbacher W Burger C Kadel C Vallbracht M Kaltenbach Collagen application for sealing of arterial puncture sites in comparison to pressure dressing: a randomized trial Cathet Cardiovasc Diagn 27 1992 298 302
    • (1992) Cathet Cardiovasc Diagn , vol.27 , pp. 298-302
    • Schräder, R1    Steinbacher, S2    Burger, W3    Kadel, C4    Vallbracht, C5    Kaltenbach, M6
  • 29
    • 0029028602 scopus 로고
    • Efficacy and safety of collagen implants for haemostasis of the vascular access site after coronary balloon angioplasty and coronary stent implantation
    • F Hoch F-J Neumann W Theiss A Kastrati A Schömig Efficacy and safety of collagen implants for haemostasis of the vascular access site after coronary balloon angioplasty and coronary stent implantation Eur Heart J 16 1995 640 646
    • (1995) Eur Heart J , vol.16 , pp. 640-646
    • Hoch, F1    Neumann, F-J2    Theiss, W3    Kastrati, A4    Schömig, A5
  • 30
    • 0344106616 scopus 로고
    • Comparison of puncture site closure with collagen plug (Vasoseal) or by early manual compression following PTCA
    • V Legrand P Doneux S Tilman Chu Comparison of puncture site closure with collagen plug (Vasoseal) or by early manual compression following PTCA Circulation 88 1993 I72
    • (1993) Circulation , vol.88 , pp. I72
    • Legrand, V1    Doneux, P2    Tilman Chu, S3
  • 31
    • 0003894895 scopus 로고
    • Routine use of collagen to seal the femoral artery puncture site after percutaneous transluminal coronary angioplasty in fully anticoagulated patients: a clinical evaluation
    • EM Nagtegaal MJ Schalij B Buis Routine use of collagen to seal the femoral artery puncture site after percutaneous transluminal coronary angioplasty in fully anticoagulated patients: a clinical evaluation J Am Coll Cardiol 21 1993 231A
    • (1993) J Am Coll Cardiol , vol.21 , pp. 231A
    • Nagtegaal, EM1    Schalij, MJ2    Buis, B3
  • 32
    • 0027372249 scopus 로고
    • Improved anticoagulation management after Palmaz Schatz coronary stent implantation by sealing the arterial puncture site with a vascular hemostasis device
    • F Kiemeneij GJ Laarman Improved anticoagulation management after Palmaz Schatz coronary stent implantation by sealing the arterial puncture site with a vascular hemostasis device Cathet Cardiovasc Diagn 30 1993 317 322
    • (1993) Cathet Cardiovasc Diagn , vol.30 , pp. 317-322
    • Kiemeneij, F1    Laarman, GJ2
  • 33
    • 85119463767 scopus 로고
    • Vergleich zwischen Kollagenapplikation und druckgesteuerter Kompression zum Verschluβ der femoralen Punktionsstelle nach diagnostischer Koronarangiographie
    • H Lehmkuhl H Dill S Haetinger I Herrmann K Bachmann Vergleich zwischen Kollagenapplikation und druckgesteuerter Kompression zum Verschluβ der femoralen Punktionsstelle nach diagnostischer Koronarangiographie Z Kardiol 82 1993 48
    • (1993) Z Kardiol , vol.82 , pp. 48
    • Lehmkuhl, H1    Dill, H2    Haetinger, S3    Herrmann, I4    Bachmann, K5
  • 34
    • 24544452024 scopus 로고
    • Comparison of hemostasis time and vascular complications between the AngioSeal hemostatic puncture closure device and manual pressure
    • JV Condon GB Elsner MT Nootens SA Gowan J Coverdale TJ Linnemeier Comparison of hemostasis time and vascular complications between the AngioSeal hemostatic puncture closure device and manual pressure Circulation 92 1995 I599
    • (1995) Circulation , vol.92 , pp. I599
    • Condon, JV1    Elsner, GB2    Nootens, MT3    Gowan, SA4    Coverdale, J5    Linnemeier, TJ6
  • 35
    • 2442621703 scopus 로고    scopus 로고
    • A randomized controlled prospective study of the Angio-Seal device versus manual pressure for rapid arterial puncture closure
    • CR Murray A Mortazavi DC Warth M Buchbinder A randomized controlled prospective study of the Angio-Seal device versus manual pressure for rapid arterial puncture closure Circulation 94 1996 I376
    • (1996) Circulation , vol.94 , pp. I376
    • Murray, CR1    Mortazavi, A2    Warth, DC3    Buchbinder, M4
  • 36
    • 0346237051 scopus 로고
    • The hemostatic puncture closure device shortens time to hemostasis and ambulation after arterial catheterization: results of a randomized study
    • H de Swart L Dijkman V van Ommen F Bär H Wellens The hemostatic puncture closure device shortens time to hemostasis and ambulation after arterial catheterization: results of a randomized study J Am Coll Cardiol 22 1994 35A
    • (1994) J Am Coll Cardiol , vol.22 , pp. 35A
    • de Swart, H1    Dijkman, L2    van Ommen, V3    Bär, F4    Wellens, H5
  • 38
    • 2642618244 scopus 로고
    • Collagen plug closure of femoral arterial punctures. Are complications excessive?
    • R Carere J Webb A Dodek Collagen plug closure of femoral arterial punctures. Are complications excessive? Circulation 90 1994 I621
    • (1994) Circulation , vol.90 , pp. I621
    • Carere, R1    Webb, J2    Dodek, A3
  • 39
    • 2642714581 scopus 로고
    • Sealing of femoral artery puncture site with percutaneously applied collagen in 1000 patients: complications requiring surgical repair
    • C Kadel W Burger M Skupin M Kaltenbach R Schräder Sealing of femoral artery puncture site with percutaneously applied collagen in 1000 patients: complications requiring surgical repair Circulation 88 1988 I-25
    • (1988) Circulation , vol.88 , pp. I-25
    • Kadel, C1    Burger, W2    Skupin, M3    Kaltenbach, M4    Schräder, R5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.