메뉴 건너뛰기




Volumn 26, Issue 8, 1998, Pages 1441-1445

Determination of cardiac output during mechanical ventilation by electrical bioimpedance or thermodilution in patients with acute lung injury: Effects of positive end-expiratory pressure

Author keywords

Acute lung injury; Cardiac output; Critical care; Electrical bioimpedance; Hemodynamics; Mechanical ventilation; Positive end expiratory pressure; Pulmonary artery catheterization; Thermodilution

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; ARTIFICIAL VENTILATION; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HEART OUTPUT; HUMAN; IMPEDANCE; INTENSIVE CARE; LUNG INJURY; MALE; POSITIVE END EXPIRATORY PRESSURE; PRIORITY JOURNAL; PROSPECTIVE STUDY; REPRODUCIBILITY; SEDATION; THERMODILUTION;

EID: 0031926922     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003246-199808000-00035     Document Type: Article
Times cited : (19)

References (25)
  • 1
    • 0027938298 scopus 로고
    • Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?
    • Boldt J, Menges T, Wollbruck M, et al: Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient? Crit Care Med 1994; 22: 1913-1918
    • (1994) Crit Care Med , vol.22 , pp. 1913-1918
    • Boldt, J.1    Menges, T.2    Wollbruck, M.3
  • 2
    • 0024237376 scopus 로고
    • Bedside catheterization of the pulmonary artery: Risks compared with benefits
    • Matthay M, Chatterjee K: Bedside catheterization of the pulmonary artery: Risks compared with benefits. Ann Intern Med 1988; 109:826-834
    • (1988) Ann Intern Med , vol.109 , pp. 826-834
    • Matthay, M.1    Chatterjee, K.2
  • 3
    • 0022975760 scopus 로고
    • Comparison of measurement of cardiac output by bioimpedance and thermodilution in severely ill surgical patients
    • Appel PL, Kram HB, Mackabee J, et al: Comparison of measurement of cardiac output by bioimpedance and thermodilution in severely ill surgical patients. Crit Care Med 1986; 14:933-935
    • (1986) Crit Care Med , vol.14 , pp. 933-935
    • Appel, P.L.1    Kram, H.B.2    Mackabee, J.3
  • 4
    • 0022979027 scopus 로고
    • Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance
    • Bernstein D: Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance. Crit Care Med 1986; 14:898-901
    • (1986) Crit Care Med , vol.14 , pp. 898-901
    • Bernstein, D.1
  • 5
    • 0025348706 scopus 로고
    • Determination of cardiac output during positive end-expiratory pressure - Noninvasive electrical bioimpedance compared with standard thermodilution
    • Castor G, Molter G, Helms J, et al: Determination of cardiac output during positive end-expiratory pressure - Noninvasive electrical bioimpedance compared with standard thermodilution. Crit Care Med 1990; 18:544-546
    • (1990) Crit Care Med , vol.18 , pp. 544-546
    • Castor, G.1    Molter, G.2    Helms, J.3
  • 6
    • 0027979916 scopus 로고
    • Simultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpedance and doppler ultrasound
    • Castor G, Klicke RK, Stoll M, et al: Simultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpedance and doppler ultrasound. Br J Anaesth 1994; 72:133-138
    • (1994) Br J Anaesth , vol.72 , pp. 133-138
    • Castor, G.1    Klicke, R.K.2    Stoll, M.3
  • 7
    • 0027303341 scopus 로고
    • Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients
    • Sageman WS, Amudson DE: Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients. Crit Care Med 1993; 21:1139-1142
    • (1993) Crit Care Med , vol.21 , pp. 1139-1142
    • Sageman, W.S.1    Amudson, D.E.2
  • 8
    • 0025786660 scopus 로고
    • Bioimpedance versus thermodilution cardiac output measurement: The Bomed NCCOM3 after coronary bypass surgery
    • Thomas AN, Ryan J, Doran BRH, et al: Bioimpedance versus thermodilution cardiac output measurement: The Bomed NCCOM3 after coronary bypass surgery. Intensive Care Med 1991; 17:383-386
    • (1991) Intensive Care Med , vol.17 , pp. 383-386
    • Thomas, A.N.1    Ryan, J.2    Doran, B.R.H.3
  • 9
    • 0028839518 scopus 로고
    • Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpedance and thermodilution
    • Doering L, Lum E, Dracup K, et al: Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpedance and thermodilution. Crit Care Med 1995; 23:1667-1673
    • (1995) Crit Care Med , vol.23 , pp. 1667-1673
    • Doering, L.1    Lum, E.2    Dracup, K.3
  • 10
    • 0025361628 scopus 로고
    • Noninvasive cardiac output: Simultaneous comparison of two different methods with thermodilution
    • Wong DH, Tremper KK, Stemmer EA, et al: Noninvasive cardiac output: Simultaneous comparison of two different methods with thermodilution. Anestheslology 1990; 72:784-792
    • (1990) Anestheslology , vol.72 , pp. 784-792
    • Wong, D.H.1    Tremper, K.K.2    Stemmer, E.A.3
  • 11
    • 0028010733 scopus 로고
    • Vertical gradient of regional lung inflation in adult respiratory distress syndrome
    • Pelosi P, D'Andrea L, Vitale G, et al: Vertical gradient of regional lung inflation in adult respiratory distress syndrome. Am J Respir Crit Care Med 1994; 149:8-13
    • (1994) Am J Respir Crit Care Med , vol.149 , pp. 8-13
    • Pelosi, P.1    D'Andrea, L.2    Vitale, G.3
  • 12
    • 0016844194 scopus 로고
    • Optimum end-expiratory pressure in patients with acute respiratory failure
    • Suter PM, Fairley HB, Isenberg MD: Optimum end-expiratory pressure in patients with acute respiratory failure. N Engl J Med 1975; 292:284-289
    • (1975) N Engl J Med , vol.292 , pp. 284-289
    • Suter, P.M.1    Fairley, H.B.2    Isenberg, M.D.3
  • 13
    • 0027417772 scopus 로고
    • Regional effects and mechanism of positive end-expiratory pressure in early adult respiratory distress syndrome
    • Gattinoni L, D'Andrea L, Pelosi P, et al: Regional effects and mechanism of positive end-expiratory pressure in early adult respiratory distress syndrome. JAMA 1993; 269:2122-2127
    • (1993) JAMA , vol.269 , pp. 2122-2127
    • Gattinoni, L.1    D'Andrea, L.2    Pelosi, P.3
  • 14
    • 0028267785 scopus 로고
    • Definitions, mechanisms, relevant outcomes, and clinical trial coordination
    • Bernard GR, Artigas A, Brigham KL, et al: Definitions, mechanisms, relevant outcomes, and clinical trial coordination. Am J Respir Crit Care Med 1994; 149:818-824
    • (1994) Am J Respir Crit Care Med , vol.149 , pp. 818-824
    • Bernard, G.R.1    Artigas, A.2    Brigham, K.L.3
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307-311
    • (1986) Lancet , vol.1 , pp. 307-311
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0029153813 scopus 로고
    • The thermodilution method for the clinical assessment of cardiac output
    • Jansen JRC: The thermodilution method for the clinical assessment of cardiac output. Intensive Care Med 1995; 21:691-697
    • (1995) Intensive Care Med , vol.21 , pp. 691-697
    • Jansen, J.R.C.1
  • 17
    • 0023493374 scopus 로고
    • Death by pulmonary artery flow-directed catheter. Time for a moratorium?
    • Robin RD: Death by pulmonary artery flow-directed catheter. Time for a moratorium? Chest 1987; 92:727-731
    • (1987) Chest , vol.92 , pp. 727-731
    • Robin, R.D.1
  • 18
    • 0022980897 scopus 로고
    • A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale
    • Bernstein DP: A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale. Crit Care Med 1986; 14:902-904
    • (1986) Crit Care Med , vol.14 , pp. 902-904
    • Bernstein, D.P.1
  • 19
    • 0002219240 scopus 로고
    • Thoracic electrical bioimpedance: Basic principles and physiologic relationship
    • Sramek BB: Thoracic electrical bioimpedance: Basic principles and physiologic relationship. Noninvas Cardiol 1994; 3:83-88
    • (1994) Noninvas Cardiol , vol.3 , pp. 83-88
    • Sramek, B.B.1
  • 20
    • 0027201173 scopus 로고
    • Thoracic electrical bioimpedance measurement of cardiac output: Not ready for prime time
    • Clarke DE, Raffin TA: Thoracic electrical bioimpedance measurement of cardiac output: Not ready for prime time. Crit Care Med 1993; 21: 1111-1112
    • (1993) Crit Care Med , vol.21 , pp. 1111-1112
    • Clarke, D.E.1    Raffin, T.A.2
  • 21
    • 85088085490 scopus 로고
    • Bioimpedance measurement of cardiac output
    • Smith DN: Bioimpedance measurement of cardiac output. Crit Care Med 1994; 22:1513-1514
    • (1994) Crit Care Med , vol.22 , pp. 1513-1514
    • Smith, D.N.1
  • 22
    • 0027458319 scopus 로고
    • Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis
    • Young JD, McQuillan P: Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis. Br J Anaesth 1993; 70:58-62
    • (1993) Br J Anaesth , vol.70 , pp. 58-62
    • Young, J.D.1    McQuillan, P.2
  • 23
    • 0029047924 scopus 로고
    • Effects of positive end-expiratory pressure on regional distribution of tidal volume and recruitment in adult respiratory distress syndrome
    • Gattinoni L, Pelosi P, Crotti S, et al: Effects of positive end-expiratory pressure on regional distribution of tidal volume and recruitment in adult respiratory distress syndrome. Am J Respir Crit Care Med 1995; 151: 1807-1814
    • (1995) Am J Respir Crit Care Med , vol.151 , pp. 1807-1814
    • Gattinoni, L.1    Pelosi, P.2    Crotti, S.3
  • 24
    • 0026547308 scopus 로고
    • Esophageal electrodes allow precise assessment of cardiac output by bioimpedance
    • Balestra B, Malacrida R, Leonardi L, et al: Esophageal electrodes allow precise assessment of cardiac output by bioimpedance. Crit Care Med 1992; 20:62-67
    • (1992) Crit Care Med , vol.20 , pp. 62-67
    • Balestra, B.1    Malacrida, R.2    Leonardi, L.3
  • 25
    • 0027971947 scopus 로고
    • Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimation
    • Shoemaker WC, Wo CCJ, Bishop MH, et al: Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimation. Crit Care Med 1994; 22:1907-1912
    • (1994) Crit Care Med , vol.22 , pp. 1907-1912
    • Shoemaker, W.C.1    Wo, C.C.J.2    Bishop, M.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.