메뉴 건너뛰기




Volumn 31, Issue 5, 1998, Pages 1185-1189

Difference between clinic and daytime blood pressure is not a measure of the white coat effect

Author keywords

Blood pressure; Blood pressure monitoring, ambulatory; Hypertension, white coat; Risk factors; Stress

Indexed keywords

ADULT; AMBULATORY MONITORING; ARTICLE; BLOOD PRESSURE MEASUREMENT; CLINICAL ARTICLE; CONTROLLED STUDY; DIASTOLIC BLOOD PRESSURE; FEMALE; HUMAN; MALE; OUTPATIENT DEPARTMENT; PRIORITY JOURNAL; SYSTOLIC BLOOD PRESSURE; TACHYCARDIA; WHITE COAT HYPERTENSION;

EID: 0031921698     PISSN: 0194911X     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.HYP.31.5.1185     Document Type: Article
Times cited : (125)

References (24)
  • 1
    • 0013935151 scopus 로고
    • A relationship between level of blood pressure measured casually and by portable recorders and severity of complications inessential hypertension
    • Sokolow M, Werdegar S, Kain H, Hinman AT. A relationship between level of blood pressure measured casually and by portable recorders and severity of complications inessential hypertension. Circulation. 1966;34: 279-298.
    • (1966) Circulation , vol.34 , pp. 279-298
    • Sokolow, M.1    Werdegar, S.2    Kain, H.3    Hinman, A.T.4
  • 2
    • 0025649758 scopus 로고
    • Presidential Lecture: Ambulatory blood pressure monitoring: research and clinical applications
    • Mancia G. Presidential Lecture: Ambulatory blood pressure monitoring: research and clinical applications. J Hypertens. 1990;8(suppl 7):S1-S13.
    • (1990) J Hypertens. , vol.8 , Issue.7 SUPPL.
    • Mancia, G.1
  • 3
    • 0023148385 scopus 로고
    • Relationship of 24-hour blood pressure mean and variability to severity of target organ damage in hypertension
    • Parati G, Pomidossi G, Albini F, Malaspina D, Mancia G. Relationship of 24-hour blood pressure mean and variability to severity of target organ damage in hypertension. Hypertension 1987;5:93-98.
    • (1987) Hypertension , vol.5 , pp. 93-98
    • Parati, G.1    Pomidossi, G.2    Albini, F.3    Malaspina, D.4    Mancia, G.5
  • 5
    • 0023100037 scopus 로고
    • Alerting reaction and rise in blood pressure during measurement by physician and nurse
    • Mancia G, Parati G, Pomidossi G, Grassi G, Casadei R, Zanchetti A. Alerting reaction and rise in blood pressure during measurement by physician and nurse. Hypertension. 1987;9:209-215.
    • (1987) Hypertension , vol.9 , pp. 209-215
    • Mancia, G.1    Parati, G.2    Pomidossi, G.3    Grassi, G.4    Casadei, R.5    Zanchetti, A.6
  • 7
    • 0029949792 scopus 로고    scopus 로고
    • Difference between office and ambulatory blood pressure and response to antihypertensive treatment
    • Parati G, Omboni S, Mancia G. Difference between office and ambulatory blood pressure and response to antihypertensive treatment. J Hypertens. 1996;14:791-797.
    • (1996) J Hypertens. , vol.14 , pp. 791-797
    • Parati, G.1    Omboni, S.2    Mancia, G.3
  • 8
    • 0024344783 scopus 로고
    • Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory test
    • Parati G, Casadei R, Groppelli A, Di Rienzo M, Mancia G. Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory test. Hypertension. 1989;13:647-655.
    • (1989) Hypertension , vol.13 , pp. 647-655
    • Parati, G.1    Casadei, R.2    Groppelli, A.3    Di Rienzo, M.4    Mancia, G.5
  • 11
    • 0029781473 scopus 로고    scopus 로고
    • White-coat hypertension: Misnomers, misconceptions and misunderstandings: what should we do next?
    • Mancia G, Zanchetti A. White-coat hypertension: misnomers, misconceptions and misunderstandings: what should we do next? J Hypertens. 1996;14:1049-1052.
    • (1996) J Hypertens. , vol.14 , pp. 1049-1052
    • Mancia, G.1    Zanchetti, A.2
  • 12
    • 0026003284 scopus 로고
    • White coat phenomenon in patients receiving antihypertensive therapy
    • Myers MG, Reeves RA. White coat phenomenon in patients receiving antihypertensive therapy. Am J Hypertens. 1991;4:844-849.
    • (1991) Am J Hypertens. , vol.4 , pp. 844-849
    • Myers, M.G.1    Reeves, R.A.2
  • 15
    • 0027513169 scopus 로고
    • Ambulatory blood pressure monitoring use in hypertension research and clinical practice
    • Mancia G, Di Rienzo M, Parati G. Ambulatory blood pressure monitoring use in hypertension research and clinical practice. Hypertension. 1993; 21:510-522.
    • (1993) Hypertension , vol.21 , pp. 510-522
    • Mancia, G.1    Di Rienzo, M.2    Parati, G.3
  • 16
    • 0024400438 scopus 로고
    • Value of ambulatory blood pressure monitoring in clinical pharmacology
    • Conway J, Coats A. Value of ambulatory blood pressure monitoring in clinical pharmacology. J Hypertens. 1989;7(suppl 3):S29-S32.
    • (1989) J Hypertens. , vol.7 , Issue.3 SUPPL.
    • Conway, J.1    Coats, A.2
  • 17
    • 0026036331 scopus 로고
    • Reproducibility of non-invasive and intra-arterial blood pressure monitoring: Implications for studies on antihypertensive treatment
    • Trazzi S, Mutti E, Frattola A, Imholz BM, Parati G, Mancia G. Reproducibility of non-invasive and intra-arterial blood pressure monitoring: implications for studies on antihypertensive treatment. J Hypertens. 1991; 9:115-119.
    • (1991) J Hypertens. , vol.9 , pp. 115-119
    • Trazzi, S.1    Mutti, E.2    Frattola, A.3    Imholz, B.M.4    Parati, G.5    Mancia, G.6
  • 18
    • 0027058399 scopus 로고
    • Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoring: Implications for studies on antihypertensive drugs
    • Mancia G, Omboni S, Parati G, Trazzi S, Mutti E. Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoring: implications for studies on antihypertensive drugs. J Hypertens. 1992;10:1531-1535.
    • (1992) J Hypertens. , vol.10 , pp. 1531-1535
    • Mancia, G.1    Omboni, S.2    Parati, G.3    Trazzi, S.4    Mutti, E.5
  • 19
    • 0002171246 scopus 로고
    • Experience with continuous non-invasive finger blood pressure monitoring: A new research tool
    • Parati G, Omboni S, Mancia G. Experience with continuous non-invasive finger blood pressure monitoring: a new research tool. Homeostasis Health Dis. 1995;36:139-152.
    • (1995) Homeostasis Health Dis. , vol.36 , pp. 139-152
    • Parati, G.1    Omboni, S.2    Mancia, G.3
  • 22
    • 0027421572 scopus 로고
    • Is white coat hypertension innocent? Structure and function of the heart in the elderly
    • Kuwajima I, Suzuki J, Fujisawa A, Kuramoto K. Is white coat hypertension innocent? Structure and function of the heart in the elderly. Hypertension. 1993;22:826-831.
    • (1993) Hypertension , vol.22 , pp. 826-831
    • Kuwajima, I.1    Suzuki, J.2    Fujisawa, A.3    Kuramoto, K.4
  • 23
    • 0023741279 scopus 로고
    • Comparison of the cardiovascular effects of different laboratory Stressors and their relationship with blood pressure variability
    • Parati G, Pomidossi G, Casadei R, Ravogli A, Groppelli A, Cesana B, Mancia G. Comparison of the cardiovascular effects of different laboratory Stressors and their relationship with blood pressure variability. J Hypertens. 1988;6:481-488.
    • (1988) J Hypertens. , vol.6 , pp. 481-488
    • Parati, G.1    Pomidossi, G.2    Casadei, R.3    Ravogli, A.4    Groppelli, A.5    Cesana, B.6    Mancia, G.7
  • 24
    • 0000429142 scopus 로고
    • Reactivity to physical and behavioral stress and blood pressure variability in hypertension
    • Julius S, Bassett DS, eds. Amsterdam, Netherlands: Elsevier
    • Mancia G, Parati G. Reactivity to physical and behavioral stress and blood pressure variability in hypertension. In: Julius S, Bassett DS, eds. Handbook of Hypertension, Vol 9. Amsterdam, Netherlands: Elsevier; 1987:104-122.
    • (1987) Handbook of Hypertension , vol.9 , pp. 104-122
    • Mancia, G.1    Parati, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.