Volumn 39, Issue 2, 1998, Pages 361-365

Variability of perceived defect size in virtual lung scintigraphy

Author keywords

Defect size; Lung scintigraphy; Monte Carlo simulation; Perception

Indexed keywords

ARTICLE; COMPUTER SIMULATION; DIAGNOSTIC ACCURACY; IMAGE ANALYSIS; LUNG EMBOLISM; LUNG SCINTISCANNING; OBSERVER VARIATION; PRIORITY JOURNAL; SYSTEM ANALYSIS;

EID: 0031918582     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (19)
  • 1
    • 0025354523 scopus 로고
    • Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED)
    • PIOPED Investigators. Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED). JAMA 1990;263:2753-2759.
    • (1990) JAMA , vol.263 , pp. 2753-2759
  • 2
    • 0027319388 scopus 로고
    • Ventilation-perfusion scintigraphy in the PIOPED study. Part I. Data collection and tabulation
    • Gottschalk A, Juni JE, Sostman HD, et al. Ventilation-perfusion scintigraphy in the PIOPED study. Part I. Data collection and tabulation. J Nucl Med 1993;34:1109-1118.
    • (1993) J Nucl Med , vol.34 , pp. 1109-1118
    • Gottschalk, A.1    Juni, J.E.2    Sostman, H.D.3
  • 3
    • 0027161356 scopus 로고
    • Ventilation-perfusion scintigraphy in the PIOPED study. Part II. Evaluation of the scintigraphic criteria and interpretations
    • Gottschalk A, Sostman HD, Coleman RE, et al. Ventilation-perfusion scintigraphy in the PIOPED study. Part II. Evaluation of the scintigraphic criteria and interpretations. J Nucl Med 1993;34:1119-1126.
    • (1993) J Nucl Med , vol.34 , pp. 1119-1126
    • Gottschalk, A.1    Sostman, H.D.2    Coleman, R.E.3
  • 4
    • 0027934581 scopus 로고
    • Evaluation of revised criteria for ventilation-perfusion scintigraphy in patients with suspected pulmonary embolism
    • Sostman HD, Coleman RE, DeLong DM, Newman GE, Paine S. Evaluation of revised criteria for ventilation-perfusion scintigraphy in patients with suspected pulmonary embolism. Radiology 1994;193:103-107.
    • (1994) Radiology , vol.193 , pp. 103-107
    • Sostman, H.D.1    Coleman, R.E.2    DeLong, D.M.3    Newman, G.E.4    Paine, S.5
  • 5
    • 0027472377 scopus 로고
    • Underestimation of segmental defect size in radionuclide lung scanning
    • Morrell NW, Nijran KS, Jones BE, Biggs T, Seed WA. Underestimation of segmental defect size in radionuclide lung scanning. J Nucl Med 1993;34:370-374.
    • (1993) J Nucl Med , vol.34 , pp. 370-374
    • Morrell, N.W.1    Nijran, K.S.2    Jones, B.E.3    Biggs, T.4    Seed, W.A.5
  • 12
    • 0001059299 scopus 로고
    • Design of a simulation system for emission tomographs
    • Lewellen TK, Anson CP, Haynor DR, et al. Design of a simulation system for emission tomographs [Abstract]. J Nucl Med 1988;29:871.
    • (1988) J Nucl Med , vol.29 , pp. 871
    • Lewellen, T.K.1    Anson, C.P.2    Haynor, D.R.3
  • 13
    • 0025940237 scopus 로고
    • The use of importance sampling techniques to improve the efficiency of photon tracking in emission tomography simulations
    • Haynor DR, Harrison RL, Lewellen TK. The use of importance sampling techniques to improve the efficiency of photon tracking in emission tomography simulations. Med Phys 1991;18:990-1001.
    • (1991) Med Phys , vol.18 , pp. 990-1001
    • Haynor, D.R.1    Harrison, R.L.2    Lewellen, T.K.3
  • 15
    • 58149412516 scopus 로고
    • Weighted kappa: Nominal scale agreement with provision for scaled disagreement or partial credit
    • Cohen J. Weighted kappa: nominal scale agreement with provision for scaled disagreement or partial credit. Psychol Bull 1968;70:213-220.
    • (1968) Psychol Bull , vol.70 , pp. 213-220
    • Cohen, J.1
  • 16
    • 0014537494 scopus 로고
    • Construction and testing of a thorax-lung phantom to aid in scintiphotograph interpretation
    • Carbonell AM, Landis GA, Miale A, Moser KM. Construction and testing of a thorax-lung phantom to aid in scintiphotograph interpretation. Invest Radiol 1969;4: 275-285.
    • (1969) Invest Radiol , vol.4 , pp. 275-285
    • Carbonell, A.M.1    Landis, G.A.2    Miale, A.3    Moser, K.M.4
  • 17
  • 19
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33:159-174.
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.