메뉴 건너뛰기




Volumn 49, Issue 3, 1998, Pages 180-185

Four-site skinfold anthropometry (FSA) versus body impedance analysis (BIA) in assessing nutritional status of patients on maintenance hemodialysis: Which method is to be preferred in routine patient care

Author keywords

Bioelectrical impedance analysis; Body fat; Four site skinfold anthropometry; Hemodialysis; Hydration status; Lean body mass

Indexed keywords

ANTHROPOMETRY; ARTICLE; BODY FAT; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HEMODIALYSIS; HUMAN; HYDRATION; IMPEDANCE; LEAN BODY WEIGHT; MALE; NUTRITIONAL STATUS; PATIENT CARE; SKINFOLD THICKNESS; TOTAL BODY WATER;

EID: 0031911486     PISSN: 03010430     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (28)

References (24)
  • 1
    • 0030046248 scopus 로고    scopus 로고
    • Impact of hemodialysis on dual X-ray absorptiometry, bioelectrical impedance measurements, and anthropometry
    • Abrahamsen B, Hansen TB, Høgsberg IM, Pedersen FB, Beck-Nielsen H 1996 Impact of hemodialysis on dual X-ray absorptiometry, bioelectrical impedance measurements, and anthropometry. Am J Clin Nutr 63: 80-86
    • (1996) Am J Clin Nutr , vol.63 , pp. 80-86
    • Abrahamsen, B.1    Hansen, T.B.2    Høgsberg, I.M.3    Pedersen, F.B.4    Beck-Nielsen, H.5
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG 1986 Statistical methods for assessing agreement between two methods of clinical measurement. Lancet i: 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 5
    • 0027351019 scopus 로고
    • The impact of hydration status on the assessment of lean body mass by body electrical impedance in dialysis patients
    • De Fijter CWH, De Fijter WM, Oe PL, Donker AJM, De Vries PMJM 1993 The impact of hydration status on the assessment of lean body mass by body electrical impedance in dialysis patients. Adv Perit Dialysis 9: 101-104
    • (1993) Adv Perit Dialysis , vol.9 , pp. 101-104
    • De Fijter, C.W.H.1    De Fijter, W.M.2    Oe, P.L.3    Donker, A.J.M.4    De Vries, P.M.J.M.5
  • 6
    • 0031031070 scopus 로고    scopus 로고
    • Assessment of total body water and lean body mass from anthropometry, Watson formula, creatinine kinetics, and body electrical impedance compared with antipyrine kinetics in peritoneal dialysis patients
    • De Fijter WM, De Fijter CWH, Oe PL, ter Wee PM, Donker AJM 1997 Assessment of total body water and lean body mass from anthropometry, Watson formula, creatinine kinetics, and body electrical impedance compared with antipyrine kinetics in peritoneal dialysis patients. Nephrol Dial Transpl 12: 151-156
    • (1997) Nephrol Dial Transpl , vol.12 , pp. 151-156
    • De Fijter, W.M.1    De Fijter, C.W.H.2    Oe, P.L.3    Ter Wee, P.M.4    Donker, A.J.M.5
  • 8
    • 0016176101 scopus 로고
    • Body fat assessed from total body density and its estimation from skinfold thickness: Measurements on 481 men and women aged from 16 to 72 years
    • Durnin JVGA, Womersley J 1974 Body fat assessed from total body density and its estimation from skinfold thickness: measurements on 481 men and women aged from 16 to 72 years. Br J Nutr 32: 77-97
    • (1974) Br J Nutr , vol.32 , pp. 77-97
    • Durnin, J.V.G.A.1    Womersley, J.2
  • 9
    • 0027516355 scopus 로고
    • Calipers vs Bia: The debate continues
    • Himmelstein S 1993 Calipers vs Bia: the debate continues. J Am Diet Ass 93: 400-401
    • (1993) J Am Diet Ass , vol.93 , pp. 400-401
    • Himmelstein, S.1
  • 10
    • 0029783946 scopus 로고    scopus 로고
    • Assessment of the nutritional state of dialysis patients
    • Kerr PG, Strauss BJG, Atkins RC 1996 Assessment of the nutritional state of dialysis patients. Blood Purif 14: 382-387
    • (1996) Blood Purif , vol.14 , pp. 382-387
    • Kerr, P.G.1    Strauss, B.J.G.2    Atkins, R.C.3
  • 11
    • 0028037318 scopus 로고
    • Effect of nutrition on morbidity and mortality in maintenance dialysis patients
    • Kopple JD 1994 Effect of nutrition on morbidity and mortality in maintenance dialysis patients. Am J Kidn Dis 24: 1002-1009
    • (1994) Am J Kidn Dis , vol.24 , pp. 1002-1009
    • Kopple, J.D.1
  • 12
    • 0025132279 scopus 로고
    • Volume status and body composition of chronic dialysis patients: Utility of bioelectric impedance plethysmography
    • Kurtin PS, Shapiro AC, Tomita H, Raizman D 1990 Volume status and body composition of chronic dialysis patients: utility of bioelectric impedance plethysmography. Am J Nephrol 10: 363-367
    • (1990) Am J Nephrol , vol.10 , pp. 363-367
    • Kurtin, P.S.1    Shapiro, A.C.2    Tomita, H.3    Raizman, D.4
  • 15
    • 0028341182 scopus 로고
    • Nutritional evaluation of hemodialysis patients using an impedance index
    • Madore F, Wuest M, Ethier JH 1994 Nutritional evaluation of hemodialysis patients using an impedance index. Clin Nephrol 41: 377-382
    • (1994) Clin Nephrol , vol.41 , pp. 377-382
    • Madore, F.1    Wuest, M.2    Ethier, J.H.3
  • 18
    • 0001049152 scopus 로고
    • Studies in body composition III: The body water and chemically combined nitrogen content in relation to fat content
    • Pace H, Rathburn EN 1945 Studies in body composition III: The body water and chemically combined nitrogen content in relation to fat content. J Biol Chem 158: 685
    • (1945) J Biol Chem , vol.158 , pp. 685
    • Pace, H.1    Rathburn, E.N.2
  • 19
    • 0026481079 scopus 로고
    • Caliper method vs. bioelectrical impedance analysis for determining body fat in patients undergoing chronic dialysis and in healthy individuals
    • Rammohan M, Aplasca EC 1992 Caliper method vs. bioelectrical impedance analysis for determining body fat in patients undergoing chronic dialysis and in healthy individuals. J Am Diet Ass 92: 1395-1397
    • (1992) J Am Diet Ass , vol.92 , pp. 1395-1397
    • Rammohan, M.1    Aplasca, E.C.2
  • 20
    • 0027485995 scopus 로고
    • Bioelectrical impedance analysis: A promising predictive tool for nutritional assessment in CAPD patients
    • Schmidt RJ, Dumler F 1993 Bioelectrical impedance analysis: a promising predictive tool for nutritional assessment in CAPD patients. Perit Dial Intern 13: 250-255
    • (1993) Perit Dial Intern , vol.13 , pp. 250-255
    • Schmidt, R.J.1    Dumler, F.2
  • 22
    • 0029048304 scopus 로고
    • Bioelectric impedance analysis and dual energy X-ray absorptiometry to monitor nutritional status
    • Stall S, Ginsberg NS, Lynn RI, Zabetakis PM 1995 Bioelectric impedance analysis and dual energy X-ray absorptiometry to monitor nutritional status. Pent Dial Intern 15: S59-S62
    • (1995) Pent Dial Intern , vol.15
    • Stall, S.1    Ginsberg, N.S.2    Lynn, R.I.3    Zabetakis, P.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.