메뉴 건너뛰기




Volumn 12, Issue 2, 1998, Pages 104-110

Frameless spinal stereotaxis

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DRILL; ORTHOPEDIC EQUIPMENT; PELVIS SURGERY; PRIORITY JOURNAL; SPINE; STEREOTAXIC SURGERY; SURGICAL ANATOMY; THREE DIMENSIONAL IMAGING;

EID: 0031903748     PISSN: 02680890     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0268-0890(98)90065-2     Document Type: Conference Paper
Times cited : (9)

References (23)
  • 1
    • 0003115598 scopus 로고
    • Internal fixation with pedicle screws
    • White AH, Rothman RH, Roy CD, eds. St Louis, MO: CV Mosby
    • Hsu J, Zucherman JF, White A. Wynne G. Internal fixation with pedicle screws. In: White AH, Rothman RH, Roy CD, eds. Lumbar Spinal Surgery. St Louis, MO: CV Mosby, 1987: 322-338.
    • (1987) Lumbar Spinal Surgery , pp. 322-338
    • Hsu, J.1    Zucherman, J.F.2    White, A.3    Wynne, G.4
  • 2
    • 0029044493 scopus 로고
    • Accuracy of pedicle screw placement in lumbar fusion by plain radiographs and CT
    • Farber GL, Place HM, Mazur RA et al. Accuracy of pedicle screw placement in lumbar fusion by plain radiographs and CT. Spine 1995; 20: 1494-1499.
    • (1995) Spine , vol.20 , pp. 1494-1499
    • Farber, G.L.1    Place, H.M.2    Mazur, R.A.3
  • 3
    • 0345515291 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement - A prospective CT-study in 30 consecutive low back patients
    • Laine T, Makito K, Poussa M et al. Accuracy of pedicle screw placement - a prospective CT-study in 30 consecutive low back patients (abstract). Eurospine '96 1996; 82: 72.
    • (1996) Eurospine '96 , vol.82 , pp. 72
    • Laine, T.1    Makito, K.2    Poussa, M.3
  • 4
    • 0031573727 scopus 로고    scopus 로고
    • The effect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusion: A prospective, randomized clinical study
    • Thomsen K, Christensen FB, Eiskjaer ?? et al. The effect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusion: a prospective, randomized clinical study. Spine 1997; 22(24): 2813-2822.
    • (1997) Spine , vol.22 , Issue.24 , pp. 2813-2822
    • Thomsen, K.1    Christensen, F.B.2    Eiskjaer3
  • 5
    • 0023790873 scopus 로고
    • Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
    • Weinstein JN, Spratt KF, Spengler D et al. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 1988; 13: 1012-1018.
    • (1988) Spine , vol.13 , pp. 1012-1018
    • Weinstein, J.N.1    Spratt, K.F.2    Spengler, D.3
  • 6
    • 0025948961 scopus 로고
    • Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine
    • Heller JG, Carlson GD, Abitbol JJ et al. Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine. Spine 1991; 16: S552-S557.
    • (1991) Spine , vol.16
    • Heller, J.G.1    Carlson, G.D.2    Abitbol, J.J.3
  • 7
    • 0026044673 scopus 로고
    • Anatomic considerations for plate-screw fixation of the cervical spine
    • An H, Gordin R, Renner K. Anatomic considerations for plate-screw fixation of the cervical spine. Spine 1991; 16(10 Suppl): S548-S551.
    • (1991) Spine , vol.16 , Issue.10 SUPPL.
    • An, H.1    Gordin, R.2    Renner, K.3
  • 8
    • 0028882788 scopus 로고
    • Complications of posterior cervical plating
    • Heller J, Silcox D, Sutterlin C. Complications of posterior cervical plating. Spine 1995; 20(22): 2442-2448.
    • (1995) Spine , vol.20 , Issue.22 , pp. 2442-2448
    • Heller, J.1    Silcox, D.2    Sutterlin, C.3
  • 10
    • 0030973318 scopus 로고    scopus 로고
    • Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
    • Madawi A, Casey A, Solanki G, Tuite G, Veres R, Crockard H. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 1997; 86: 961-968.
    • (1997) J Neurosurg , vol.86 , pp. 961-968
    • Madawi, A.1    Casey, A.2    Solanki, G.3    Tuite, G.4    Veres, R.5    Crockard, H.6
  • 11
    • 1842332093 scopus 로고    scopus 로고
    • Variation of the groove in the axis vertebra for the vertebral artery: Implications for instrumentation
    • Madawi A, Solanki G, Casey A, Crockard H. Variation of the groove in the axis vertebra for the vertebral artery: implications for instrumentation. J Bone Joint Surg 1997; 79B(5): 820-823.
    • (1997) J Bone Joint Surg , vol.79 B , Issue.5 , pp. 820-823
    • Madawi, A.1    Solanki, G.2    Casey, A.3    Crockard, H.4
  • 12
    • 1842414315 scopus 로고    scopus 로고
    • Unilateral posterior atlantoaxial transarticular screw fixation
    • Song GS, Theodore N, Dickman C, Sonntag V. Unilateral posterior atlantoaxial transarticular screw fixation. J Neurosurg 1997; 87: 851-855.
    • (1997) J Neurosurg , vol.87 , pp. 851-855
    • Song, G.S.1    Theodore, N.2    Dickman, C.3    Sonntag, V.4
  • 13
    • 0002936907 scopus 로고
    • Image-guided intraoperative spinal localization
    • Andrews RJ, ed. Baltimore, MD: Williams and Wilkins
    • Foley KT, Smith KR, Bucholz RD. Image-guided intraoperative spinal localization. In: Andrews RJ, ed. Intraoperative Neuroprotection. Baltimore, MD: Williams and Wilkins, 1995: 325-340.
    • (1995) Intraoperative Neuroprotection , pp. 325-340
    • Foley, K.T.1    Smith, K.R.2    Bucholz, R.D.3
  • 14
  • 16
    • 0028469070 scopus 로고
    • The NeuroStation™ - A highly accurate, minimally invasive solution to frameless stereotactic neurosurgery
    • Smith KR, Frank KJ, Bucholz RD. The NeuroStation™ - a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery. Computerized Medical Imaging and Graphics 1994; 18: 247-256.
    • (1994) Computerized Medical Imaging and Graphics , vol.18 , pp. 247-256
    • Smith, K.R.1    Frank, K.J.2    Bucholz, R.D.3
  • 20
    • 0029760974 scopus 로고    scopus 로고
    • Computer-aided pedicle screw placement using frameless stereotaxis
    • Glossop ND, Hu RW, Randle JA. Computer-aided pedicle screw placement using frameless stereotaxis. Spine 1996; 21(17): 2026-2034.
    • (1996) Spine , vol.21 , Issue.17 , pp. 2026-2034
    • Glossop, N.D.1    Hu, R.W.2    Randle, J.A.3
  • 21
    • 0002669361 scopus 로고    scopus 로고
    • Frameless stereotactic guidance of cervical spine lateral mass screw placement
    • Nolte L-P, Ganz R, eds. Bern, Switzerland: Hogrefe & Huber Publishers (in press)
    • Foley KT, Smith KR, Smith MM. Frameless stereotactic guidance of cervical spine lateral mass screw placement. In: Nolte L-P, Ganz R, eds. Computer Assisted Orthopaedic Surgery (CAOS). Bern, Switzerland: Hogrefe & Huber Publishers (in press).
    • Computer Assisted Orthopaedic Surgery (CAOS)
    • Foley, K.T.1    Smith, K.R.2    Smith, M.M.3
  • 22
    • 0006026676 scopus 로고    scopus 로고
    • Frameless stereotactic guidance of C1-2 transarticular screw placement: Clinical experience
    • Foley KT, Smith, MM. Frameless stereotactic guidance of C1-2 transarticular screw placement: clinical experience (abstract). J Neurosurg 1997; 86(2): 360A.
    • (1997) J Neurosurg , vol.86 , Issue.2
    • Foley, K.T.1    Smith, M.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.