메뉴 건너뛰기




Volumn 18, Issue 3, 1998, Pages 256-259

Management of peritoneal catheter malfunction

Author keywords

[No Author keywords available]

Indexed keywords

DIALYSIS FLUID; ENEMA; FIBRIN; HEPARIN; STREPTOKINASE; UROKINASE;

EID: 0031902173     PISSN: 08968608     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Short Survey
Times cited : (30)

References (36)
  • 1
    • 0027944147 scopus 로고
    • A retrospective analysis of catheter position and function in 91 CAPD patients
    • Ersoy FF, Twardowski ZJ, Satalowich RJ, Ketchersid T. A retrospective analysis of catheter position and function in 91 CAPD patients. Perit Dial Int 1994; 14:409-10.
    • (1994) Perit Dial Int , vol.14 , pp. 409-410
    • Ersoy, F.F.1    Twardowski, Z.J.2    Satalowich, R.J.3    Ketchersid, T.4
  • 2
    • 0025252960 scopus 로고
    • A comparison of two types of catheters for continuous ambulatory peritoneal dialysis (CAPD)
    • Akyol AM, Porteous C, Brown MW. A comparison of two types of catheters for continuous ambulatory peritoneal dialysis (CAPD). Perit Dial Int 1990; 10:63-6.
    • (1990) Perit Dial Int , vol.10 , pp. 63-66
    • Akyol, A.M.1    Porteous, C.2    Brown, M.W.3
  • 3
    • 0030724642 scopus 로고    scopus 로고
    • Peritoneal dialysis catheter malfunction due to compartmentalization
    • Diaz-Buxo JA. Peritoneal dialysis catheter malfunction due to compartmentalization. Perit Dial Int 1997; 17:209-10.
    • (1997) Perit Dial Int , vol.17 , pp. 209-210
    • Diaz-Buxo, J.A.1
  • 4
    • 0001681704 scopus 로고
    • Intraperitoneal infusion of streptokinase in the treatment of recurrent peritonitis
    • Block RA, Taylor B, Frederick G. Intraperitoneal infusion of streptokinase in the treatment of recurrent peritonitis. Perit Dial Bull 1983; 3:162.
    • (1983) Perit Dial Bull , vol.3 , pp. 162
    • Block, R.A.1    Taylor, B.2    Frederick, G.3
  • 6
    • 0024588312 scopus 로고
    • Tenckhoff catheter replacement or intraperitoneal urokinase: A randomized trial in the management of recurrent continuous ambulatory peritoneal dialysis peritonitis
    • Williams A, Boletis I, Johnson BF, Raftery AT, Cohen CI, Moorhead PJ, et al. Tenckhoff catheter replacement or intraperitoneal urokinase: A randomized trial in the management of recurrent continuous ambulatory peritoneal dialysis peritonitis. Perit Dial Bull 1989; 9:65-7.
    • (1989) Perit Dial Bull , vol.9 , pp. 65-67
    • Williams, A.1    Boletis, I.2    Johnson, B.F.3    Raftery, A.T.4    Cohen, C.I.5    Moorhead, P.J.6
  • 7
    • 0030345158 scopus 로고    scopus 로고
    • A simple method for opening an obstructed peritoneal catheter using an infusion accelerator
    • Khanna R, ed. Toronto: Peritoneal Dialysis Publications
    • Hashimoto Y, Yano S, Nakanishi Y, Suzuki S, Tsutsumi M. A simple method for opening an obstructed peritoneal catheter using an infusion accelerator, In: Khanna R, ed. Advances in peritoneal dialysis. Toronto: Peritoneal Dialysis Publications, 1996; 12:227-30.
    • (1996) Advances in Peritoneal Dialysis , vol.12 , pp. 227-230
    • Hashimoto, Y.1    Yano, S.2    Nakanishi, Y.3    Suzuki, S.4    Tsutsumi, M.5
  • 8
    • 0025100602 scopus 로고
    • Malpositioned peritoneal dialysis catheters: A critical reappraisal of correction by wire manipulation
    • Moss JS, Minda SA, Newman GE, Dunnick NR, Vernon WB, Schwab SJ. Malpositioned peritoneal dialysis catheters: a critical reappraisal of correction by wire manipulation. Am J Kidney Dis 1990; 15:305-8.
    • (1990) Am J Kidney Dis , vol.15 , pp. 305-308
    • Moss, J.S.1    Minda, S.A.2    Newman, G.E.3    Dunnick, N.R.4    Vernon, W.B.5    Schwab, S.J.6
  • 9
    • 0030924326 scopus 로고    scopus 로고
    • Fluoroscopic manipulation of Tenckhoff catheters: Outcome analysis
    • Diaz-Buxo JA, Turner MW, Nelms M. Fluoroscopic manipulation of Tenckhoff catheters: outcome analysis. Clin Nephrol 1997; 47:384-8.
    • (1997) Clin Nephrol , vol.47 , pp. 384-388
    • Diaz-Buxo, J.A.1    Turner, M.W.2    Nelms, M.3
  • 10
    • 0021916777 scopus 로고
    • Tenckhoff peritoneal dialysis catheters: The use of fluoroscopy in management
    • Degesys GE, Miller GA, Ford KK, Dunnick NR. Tenckhoff peritoneal dialysis catheters: The use of fluoroscopy in management. Radiology 1985; 154:819-20.
    • (1985) Radiology , vol.154 , pp. 819-820
    • Degesys, G.E.1    Miller, G.A.2    Ford, K.K.3    Dunnick, N.R.4
  • 11
    • 0018897535 scopus 로고
    • Tenckhoff peritoneal dialysis catheters: Cannulography and manipulation
    • Jacques P, Richey W, Mandel S. Tenckhoff peritoneal dialysis catheters: Cannulography and manipulation. Am J Radiol 1980; 135:83-6.
    • (1980) Am J Radiol , vol.135 , pp. 83-86
    • Jacques, P.1    Richey, W.2    Mandel, S.3
  • 15
    • 4243431095 scopus 로고    scopus 로고
    • The role of Fogarty catheter manipulation in the management of migrated, non-functional peritoneal dialysis Tenckhoff catheters
    • Gadallah MF, Arumugam R, Moles K, Arora N. The role of Fogarty catheter manipulation in the management of migrated, non-functional peritoneal dialysis Tenckhoff catheters (Abstract). J Am Soc Nephrol 1997; 8:179A.
    • (1997) J Am Soc Nephrol , vol.8
    • Gadallah, M.F.1    Arumugam, R.2    Moles, K.3    Arora, N.4
  • 16
    • 0030330060 scopus 로고    scopus 로고
    • Use of laparoscopy in the management of malfunctioning peritoneal dialysis catheters
    • Khanna R, ed. Toronto: Peritoneal Dialysis Publications
    • Brandt CP, Ricanati ES. Use of laparoscopy in the management of malfunctioning peritoneal dialysis catheters. In: Khanna R, ed. Advances in peritoneal dialysis. Toronto: Peritoneal Dialysis Publications, 1996; 12:223-6.
    • (1996) Advances in Peritoneal Dialysis , vol.12 , pp. 223-226
    • Brandt, C.P.1    Ricanati, E.S.2
  • 18
    • 0028802912 scopus 로고
    • Malfunctioning peritoneal dialysis catheter repaired by laparoscopic surgery
    • Julian TB, Ribeiro U, Bruns F, Fraley D. Malfunctioning peritoneal dialysis catheter repaired by laparoscopic surgery. Perit Dial Int 1995; 15:363-6.
    • (1995) Perit Dial Int , vol.15 , pp. 363-366
    • Julian, T.B.1    Ribeiro, U.2    Bruns, F.3    Fraley, D.4
  • 20
    • 0030011418 scopus 로고    scopus 로고
    • Laparoscopic epiplopexy of the greater omentum and epiploic appendices in the salvaging of dysfunctional peritoneal dialysis catheters
    • Crabtree JH, Fishman A. Laparoscopic epiplopexy of the greater omentum and epiploic appendices in the salvaging of dysfunctional peritoneal dialysis catheters. Surg Laparosc Endosc 1996; 6:176-80.
    • (1996) Surg Laparosc Endosc , vol.6 , pp. 176-180
    • Crabtree, J.H.1    Fishman, A.2
  • 21
    • 0030163231 scopus 로고    scopus 로고
    • Laparoscopic introduction of a continuous ambulatory peritoneal dialysis (CAPD) catheter by a two-puncture technique
    • Nijhuis PH, Smulders JF, Jakimowicz JJ. Laparoscopic introduction of a continuous ambulatory peritoneal dialysis (CAPD) catheter by a two-puncture technique. Surg Endosc 1996; 10:676-9.
    • (1996) Surg Endosc , vol.10 , pp. 676-679
    • Nijhuis, P.H.1    Smulders, J.F.2    Jakimowicz, J.J.3
  • 22
    • 0021806650 scopus 로고
    • Peritoneoscopy in the management of catheter malfunction during continuous ambulatory peritoneal dialysis
    • Wilson JAP, Swartz RD. Peritoneoscopy in the management of catheter malfunction during continuous ambulatory peritoneal dialysis. Dig Dis Sci 1985; 30:465-72.
    • (1985) Dig Dis Sci , vol.30 , pp. 465-472
    • Wilson, J.A.P.1    Swartz, R.D.2
  • 23
    • 0024596686 scopus 로고
    • Value of peritoneoscopy for nonfunctioning continuous ambulatory peritoneal dialysis catheters
    • Smith DW, Rankin RA. Value of peritoneoscopy for nonfunctioning continuous ambulatory peritoneal dialysis catheters. Gastrointest Endosc 1989; 35:90-2.
    • (1989) Gastrointest Endosc , vol.35 , pp. 90-92
    • Smith, D.W.1    Rankin, R.A.2
  • 24
    • 0025230214 scopus 로고
    • Laparoscopic repositioning of blocked peritoneal dialysis catheters in patients on CAPD
    • Gibson DH, Healsey RN, Price JH, Doherty CC, Douglas JF. Laparoscopic repositioning of blocked peritoneal dialysis catheters in patients on CAPD (Letter). Clin Nephrol 1990; 33:208.
    • (1990) Clin Nephrol , vol.33 , pp. 208
    • Gibson, D.H.1    Healsey, R.N.2    Price, J.H.3    Doherty, C.C.4    Douglas, J.F.5
  • 25
    • 0027257876 scopus 로고
    • Laparoscopic rescue of dysfunctional Tenckhoff catheters in continuous ambulatory peritoneal dialysis patients
    • Chao S, Tsai T. Laparoscopic rescue of dysfunctional Tenckhoff catheters in continuous ambulatory peritoneal dialysis patients (Letter). Nephron 1993; 65:157-8.
    • (1993) Nephron , vol.65 , pp. 157-158
    • Chao, S.1    Tsai, T.2
  • 28
    • 0003884640 scopus 로고
    • Comparison of the survival and complications of three permanent peritoneal dialysis catheters
    • Ponce SP, Pierratos A, Izatt S, Mathews R, Khanna R, Zellerman G, et al. Comparison of the survival and complications of three permanent peritoneal dialysis catheters. Perit Dial Bull 1982; 2:82-6.
    • (1982) Perit Dial Bull , vol.2 , pp. 82-86
    • Ponce, S.P.1    Pierratos, A.2    Izatt, S.3    Mathews, R.4    Khanna, R.5    Zellerman, G.6
  • 29
    • 0021204577 scopus 로고
    • Single cuff versus double cuff Tenckhoff catheter
    • Diaz-Buxo JA, Geissinger WT. Single cuff versus double cuff Tenckhoff catheter. Perit Dial Bull 1984; 4:S100-2.
    • (1984) Perit Dial Bull , vol.4
    • Diaz-Buxo, J.A.1    Geissinger, W.T.2
  • 32
    • 0023849662 scopus 로고
    • Complications with permanent peritoneal dialysis catheters: Experience with 154 permanently placed catheters
    • Allon M, Soucie JM, Macon EJ. Complications with permanent peritoneal dialysis catheters: Experience with 154 permanently placed catheters. Nephron 1988; 48:8-11.
    • (1988) Nephron , vol.48 , pp. 8-11
    • Allon, M.1    Soucie, J.M.2    Macon, E.J.3
  • 33
    • 0028133306 scopus 로고
    • Peritoneal dialysis access. Prospective randomized trial of 3 different peritoneal catheters - Preliminary report
    • Scott PD, Bakran A, Pearson R, Riad H, Parrott N, Johnson RWG, et al. Peritoneal dialysis access. Prospective randomized trial of 3 different peritoneal catheters - preliminary report. Perit Dial Int 1994; 14:289-90.
    • (1994) Perit Dial Int , vol.14 , pp. 289-290
    • Scott, P.D.1    Bakran, A.2    Pearson, R.3    Riad, H.4    Parrott, N.5    Johnson, R.W.G.6
  • 35
    • 0028939443 scopus 로고
    • Comparison of straight and curled Tenckhoff peritoneal dialysis catheters implanted by percutaneous technique: A prospective randomized study
    • Nielsen PK, Hemmingsen C, Friis SU, Ladefoged J, Olgaard K. Comparison of straight and curled Tenckhoff peritoneal dialysis catheters implanted by percutaneous technique: a prospective randomized study. Perit Dial Int 1995; 15:18-21.
    • (1995) Perit Dial Int , vol.15 , pp. 18-21
    • Nielsen, P.K.1    Hemmingsen, C.2    Friis, S.U.3    Ladefoged, J.4    Olgaard, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.