메뉴 건너뛰기




Volumn 15, Issue 2, 1998, Pages 129-132

Transvaginal sonography of the forewaters in the assessment of amniotic fluid volume in patients with oligohydramnios

Author keywords

Amniotic fluid index; Forewaters; Oligohydramnios; Pregnancy; Transvaginal ultrasound

Indexed keywords

ADULT; AMNION FLUID ANALYSIS; ARTICLE; FEMALE; FETUS; GESTATIONAL AGE; HUMAN; MAJOR CLINICAL STUDY; MATERNAL AGE; OLIGOHYDRAMNIOS; PRIORITY JOURNAL; PROSPECTIVE STUDY; TRANSVAGINAL ECHOGRAPHY;

EID: 0031901452     PISSN: 07351631     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2007-993912     Document Type: Article
Times cited : (5)

References (20)
  • 1
    • 0024323628 scopus 로고
    • Normal amniotic fluid volume changes throughout pregnancy
    • Brace RA, Wolf EJ. Normal amniotic fluid volume changes throughout pregnancy. Am J Obstet Gynecol 1989;161: 382-388
    • (1989) Am J Obstet Gynecol , vol.161 , pp. 382-388
    • Brace, R.A.1    Wolf, E.J.2
  • 2
    • 0027761063 scopus 로고
    • Amniotic fluid index: Gestational age specific values for normal human pregnancy
    • Hallak M, Kirshon B, Smith EO, Cotton DB. Amniotic fluid index: Gestational age specific values for normal human pregnancy. J Reprod Med 1993;38:853-856
    • (1993) J Reprod Med , vol.38 , pp. 853-856
    • Hallak, M.1    Kirshon, B.2    Smith, E.O.3    Cotton, D.B.4
  • 3
    • 0025341260 scopus 로고
    • The amniotic fluid index in normal human pregnancy
    • Moore TR, Cayle JE. The amniotic fluid index in normal human pregnancy. Am J Obstet Gynecol 1990;162: 1168-1173
    • (1990) Am J Obstet Gynecol , vol.162 , pp. 1168-1173
    • Moore, T.R.1    Cayle, J.E.2
  • 4
    • 0023226864 scopus 로고
    • Amniotic fluid volume assessment with the four-quadrant technique at 36-42 weeks' gestation
    • Phelan JP, Smith CV, Broussard P, Small M. amniotic fluid volume assessment with the four-quadrant technique at 36-42 weeks' gestation. J Reprod Med 1987;32:540-542
    • (1987) J Reprod Med , vol.32 , pp. 540-542
    • Phelan, J.P.1    Smith, C.V.2    Broussard, P.3    Small, M.4
  • 5
    • 0022587021 scopus 로고
    • Limitations of using maximum vertical pocket and other sonographic evaluations of amniotic fluid volume to predict fetal growth: Technical or physiologic?
    • Bottoms SF, Welch RA, Zador IE, Sokol RJ. Limitations of using maximum vertical pocket and other sonographic evaluations of amniotic fluid volume to predict fetal growth: Technical or physiologic? Am J Obstet Gynecol 1986;155:154-158
    • (1986) Am J Obstet Gynecol , vol.155 , pp. 154-158
    • Bottoms, S.F.1    Welch, R.A.2    Zador, I.E.3    Sokol, R.J.4
  • 7
    • 0025168853 scopus 로고
    • Superiority of the four-quadrant sum over the single-deepest-pocket technique in ultrasonographic identification of abnormal amniotic fluid volume
    • Moore TR. Superiority of the four-quadrant sum over the single-deepest-pocket technique in ultrasonographic identification of abnormal amniotic fluid volume. Am J Obstet Gynecol 1990;163:762-767
    • (1990) Am J Obstet Gynecol , vol.163 , pp. 762-767
    • Moore, T.R.1
  • 8
    • 0020637933 scopus 로고
    • Oligohydramnios: Ultrasonically detected incidence and subsequent fetal outcome
    • Hill LM, Breckle R, Wolfgram KR, O'Brien PC. Oligohydramnios: Ultrasonically detected incidence and subsequent fetal outcome. Am J Obstet Gynecol 1983;147: 407-410
    • (1983) Am J Obstet Gynecol , vol.147 , pp. 407-410
    • Hill, L.M.1    Breckle, R.2    Wolfgram, K.R.3    O'Brien, P.C.4
  • 9
    • 0021253094 scopus 로고
    • A survey of pregnancies complicated by decreased amniotic fluid volume
    • Mercer LJ, Brown LG, Petres RE, Messer RH. A survey of pregnancies complicated by decreased amniotic fluid volume. Am J Obstet Gynecol 1984;149:355-361
    • (1984) Am J Obstet Gynecol , vol.149 , pp. 355-361
    • Mercer, L.J.1    Brown, L.G.2    Petres, R.E.3    Messer, R.H.4
  • 11
    • 0028931782 scopus 로고
    • Longitudinal measurement of amniotic fluid index in postterm pregnancies and its association with fetal outcome
    • Divon MY, Marks AD, Henderson CE. Longitudinal measurement of amniotic fluid index in postterm pregnancies and its association with fetal outcome. Am J Obstet Gynecol 1995;172:142-146
    • (1995) Am J Obstet Gynecol , vol.172 , pp. 142-146
    • Divon, M.Y.1    Marks, A.D.2    Henderson, C.E.3
  • 12
    • 0021353216 scopus 로고
    • The value of ultrasound measurement of amniotic fluid volume in the management of prolonged pregnancies
    • Crowley P, O'Herlihy C, Boylan P. The value of ultrasound measurement of amniotic fluid volume in the management of prolonged pregnancies. Br J Obstet Gynecol 1984;91:444-448
    • (1984) Br J Obstet Gynecol , vol.91 , pp. 444-448
    • Crowley, P.1    O'Herlihy, C.2    Boylan, P.3
  • 13
    • 0021925303 scopus 로고
    • The role of ultrasound assessment of amniotic fluid volume in the management of postdate pregnancy
    • Phelan JP, Platt LD, Yeh SY, Broussard P, Paul RH. The role of ultrasound assessment of amniotic fluid volume in the management of postdate pregnancy. Am J Obstet Gynecol 1985;151:304-308
    • (1985) Am J Obstet Gynecol , vol.151 , pp. 304-308
    • Phelan, J.P.1    Platt, L.D.2    Yeh, S.Y.3    Broussard, P.4    Paul, R.H.5
  • 14
    • 84982712509 scopus 로고
    • Ultrasound assessment of amniotic fluid volume: A comparison of the single deepest pool and amniotic fluid index to predict perinatal morbidity
    • Ajayi RA, Soothill PW. Ultrasound assessment of amniotic fluid volume: A comparison of the single deepest pool and amniotic fluid index to predict perinatal morbidity. Ultrasound Obstet Gynecol 1991;1:401-404
    • (1991) Ultrasound Obstet Gynecol , vol.1 , pp. 401-404
    • Ajayi, R.A.1    Soothill, P.W.2
  • 15
    • 84989040636 scopus 로고
    • Intraobserver reliability of amniotic fluid volume estimation by two techniques: Amniotic fluid index vs. maximum vertical pocket
    • Williams K, Wittman B, Dansereau J. Intraobserver reliability of amniotic fluid volume estimation by two techniques: Amniotic fluid index vs. maximum vertical pocket. Ultrasound Obstet Gynecol 1993;3:346-349
    • (1993) Ultrasound Obstet Gynecol , vol.3 , pp. 346-349
    • Williams, K.1    Wittman, B.2    Dansereau, J.3
  • 16
    • 0029422327 scopus 로고
    • Reproducibility of the amniotic fluid index: Its effect on clinical practice
    • Chang TC, Yeo SH, Huang HF, Leng JH. Reproducibility of the amniotic fluid index: Its effect on clinical practice. Ultrasound Obstet Gynecol 1995;6:416-420
    • (1995) Ultrasound Obstet Gynecol , vol.6 , pp. 416-420
    • Chang, T.C.1    Yeo, S.H.2    Huang, H.F.3    Leng, J.H.4
  • 18
    • 0023262143 scopus 로고
    • Four-quadrant assessment of amniotic fluid volume. Intraobserver and interobserver variation
    • Rutherford SE, Smith CV, Phelan JP, Kawakami K, Ahn MO. Four-quadrant assessment of amniotic fluid volume. Intraobserver and interobserver variation. J Reprod Med 1987;32:587-589
    • (1987) J Reprod Med , vol.32 , pp. 587-589
    • Rutherford, S.E.1    Smith, C.V.2    Phelan, J.P.3    Kawakami, K.4    Ahn, M.O.5
  • 20
    • 0027956261 scopus 로고
    • The influence of operator transducer pressure on ultrasonographic measurements of amniotic fluid volume
    • Flack NJ, Doré C, Southwell D, Kourtis P, Sepulveda W, Fisk NM. The influence of operator transducer pressure on ultrasonographic measurements of amniotic fluid volume. Am J Obstet Gynecol 1994;171:218-222
    • (1994) Am J Obstet Gynecol , vol.171 , pp. 218-222
    • Flack, N.J.1    Doré, C.2    Southwell, D.3    Kourtis, P.4    Sepulveda, W.5    Fisk, N.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.