메뉴 건너뛰기




Volumn 22, Issue 5, 1998, Pages 411-413

Estimation of the native cardiac output from a rotary blood pump flow: In vitro study

Author keywords

Left ventricular assist device; Pulsatility; Pulse power index; Rotary blood pump

Indexed keywords

ARTIFICIAL HEART; BLOOD; FAST FOURIER TRANSFORMS; FIBER OPTIC SENSORS; HEART; HEMODYNAMICS; PUMPS;

EID: 0031898939     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1594.1998.06127.x     Document Type: Article
Times cited : (13)

References (9)
  • 2
    • 0030036571 scopus 로고    scopus 로고
    • Can we develop a non-pulsatile permanent rotary blood pump? Yes, we can
    • Nosé Y, Kawahito K, Nakazawa T. Can we develop a non-pulsatile permanent rotary blood pump? Yes, we can. Artif Organs 1996;20(6):467-74.
    • (1996) Artif Organs , vol.20 , Issue.6 , pp. 467-474
    • Nosé, Y.1    Kawahito, K.2    Nakazawa, T.3
  • 3
    • 0030101862 scopus 로고    scopus 로고
    • Can we treat dilated cardiomyopathy using a left ventricular assist device?
    • Tayama E, Nosé Y. Can we treat dilated cardiomyopathy using a left ventricular assist device? Artif Organs 1996;20(3): 197-201.
    • (1996) Artif Organs , vol.20 , Issue.3 , pp. 197-201
    • Tayama, E.1    Nosé, Y.2
  • 4
    • 0022366987 scopus 로고
    • Quantification of pulsatile flow during cardiopulmonary bypass to permit direct comparison of the effectiveness of various type of "pulsatile" and "nonpulsatile" flow
    • Grossi EA, Connolly MW, Krieger KH, Nathan IM, Hunter CE, Colvin SB, Baumann C, Frank FC. Quantification of pulsatile flow during cardiopulmonary bypass to permit direct comparison of the effectiveness of various type of "pulsatile" and "nonpulsatile" flow, Surgery 1985;98:547-53.
    • (1985) Surgery , vol.98 , pp. 547-553
    • Grossi, E.A.1    Connolly, M.W.2    Krieger, K.H.3    Nathan, I.M.4    Hunter, C.E.5    Colvin, S.B.6    Baumann, C.7    Frank, F.C.8
  • 5
    • 0001429468 scopus 로고
    • The effect of "pulsation" on resistance during extracorporeal circulation experimental study based on the quantification of pulsatile flow curve
    • Souma A. The effect of "pulsation" on resistance during extracorporeal circulation experimental study based on the quantification of pulsatile flow curve. J Jpn Assoc Thorac Surg 1988;36(9):102-11.
    • (1988) J Jpn Assoc Thorac Surg , vol.36 , Issue.9 , pp. 102-111
    • Souma, A.1
  • 6
  • 8
    • 0030946449 scopus 로고    scopus 로고
    • Flow rate measurement for the magnetically suspended centrifugal blood pump
    • Tsukiya T, Akamatsu T, Nishimura K. Flow rate measurement for the magnetically suspended centrifugal blood pump. Jpn J Artif Organs 1997;26(1):98-102.
    • (1997) Jpn J Artif Organs , vol.26 , Issue.1 , pp. 98-102
    • Tsukiya, T.1    Akamatsu, T.2    Nishimura, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.