메뉴 건너뛰기




Volumn 43, Issue 1, 1998, Pages 49-64

Computerized optimization of multiple isocentres in stereotactic convergent beam irradiation

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; AUTOMATION; COLLIMATOR; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; DOSIMETRY; NUCLEAR MAGNETIC RESONANCE; PRIORITY JOURNAL; RADIOSURGERY; STEREOTAXIC SURGERY; TARGET ORGAN; TREATMENT PLANNING;

EID: 0031892832     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/43/1/004     Document Type: Article
Times cited : (13)

References (19)
  • 2
    • 0025103658 scopus 로고
    • Methods of image reconstruction from projections applied to conformation radiotherapy
    • Bortfeld T, Bürkelbach J, Boesecke R and Schlegel W 1990 Methods of image reconstruction from projections applied to conformation radiotherapy Phys. Med. Biol. 35 1423-34
    • (1990) Phys. Med. Biol. , vol.35 , pp. 1423-1434
    • Bortfeld, T.1    Bürkelbach, J.2    Boesecke, R.3    Schlegel, W.4
  • 7
    • 0028839218 scopus 로고
    • Treatment planning optimization for multiple arcs stereotactic radiosurgery using a linear accelerator
    • Lam CF, Zhu JG, Fenn JO and Jenrette III JM 1995 Treatment planning optimization for multiple arcs stereotactic radiosurgery using a linear accelerator Int. J. Radiat. Oncol. Biol. Phys. 33 647-57
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.33 , pp. 647-657
    • Lam, C.F.1    Zhu, J.G.2    Fenn, J.O.3    Jenrette III, J.M.4
  • 12
    • 0029791316 scopus 로고    scopus 로고
    • Effects of irradiation geometry on treatment plan optimization with linac-based radiosurgery
    • Phillips MH, Stelzer KJ, Mayberg MR and Winn HR 1996 Effects of irradiation geometry on treatment plan optimization with linac-based radiosurgery Med. Phys. 23 1399-406
    • (1996) Med. Phys. , vol.23 , pp. 1399-1406
    • Phillips, M.H.1    Stelzer, K.J.2    Mayberg, M.R.3    Winn, H.R.4
  • 15
    • 0029937772 scopus 로고    scopus 로고
    • Computer-aided design optimization with the use of a fast dose model for linear-accelerator-based stereotactic radiosurgery
    • Suh TS, Bova FJ, Yoon SC, Choe BY, Kim MC, Shinn KS, Bakh YW, Ha SW and Park CI 1996 Computer-aided design optimization with the use of a fast dose model for linear-accelerator-based stereotactic radiosurgery Phys. Med. Biol. 41 675-96
    • (1996) Phys. Med. Biol. , vol.41 , pp. 675-696
    • Suh, T.S.1    Bova, F.J.2    Yoon, S.C.3    Choe, B.Y.4    Kim, M.C.5    Shinn, K.S.6    Bakh, Y.W.7    Ha, S.W.8    Park, C.I.9
  • 16
    • 0027226315 scopus 로고
    • Optimisation of dose distribution for linear accelerator-based stereotactic radiosurgery
    • Suh TS, Bova F, Yoon SC, Shinn KS and Bakh YW 1993 Optimisation of dose distribution for linear accelerator-based stereotactic radiosurgery Med. Biol. Eng. Comput. 31 S23-S30
    • (1993) Med. Biol. Eng. Comput. , vol.31
    • Suh, T.S.1    Bova, F.2    Yoon, S.C.3    Shinn, K.S.4    Bakh, Y.W.5
  • 17
    • 0029058657 scopus 로고
    • The physics of radiosurgery
    • ed JG Schwade (Orlando, FL: Saunders)
    • Verhey LJ and Smith V 1995 The physics of radiosurgery Seminars in Radiation Oncology vol 5 ed JG Schwade (Orlando, FL: Saunders) pp 175-91
    • (1995) Seminars in Radiation Oncology , vol.5 , pp. 175-191
    • Verhey, L.J.1    Smith, V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.