메뉴 건너뛰기




Volumn 3, Issue 1, 1998, Pages 1-7

Continuous versus occasional measurement of blood pressure in reactivity testing

Author keywords

Blood pressure measurement; Cardiovascular reactivity; Finapres device; Psychophysiology

Indexed keywords

ADULT; ARTICLE; AVERAGING; BLOOD PRESSURE MEASUREMENT; CARDIOVASCULAR RESPONSE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIASTOLIC BLOOD PRESSURE; FEMALE; HEART RATE; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; MALE; NORMAL HUMAN; PRIORITY JOURNAL; PSYCHOPHYSIOLOGY; STRESS; SYSTOLIC BLOOD PRESSURE; VARIANCE;

EID: 0031892033     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (22)
  • 1
    • 0002220170 scopus 로고
    • Photo electric measurement of blood pressure, volume and flow in the finger
    • Albert A, Vogt W, Helbig W (editors): Dresden: International Federation for Medical and Biological Engineering
    • Peñaz J. Photo electric measurement of blood pressure, volume and flow in the finger. In Albert A, Vogt W, Helbig W (editors): Digest of the 10th International Conference on Medical and Biological Engineering. Dresden: International Federation for Medical and Biological Engineering; 1973. p. 104.
    • (1973) Digest of the 10th International Conference on Medical and Biological Engineering , pp. 104
    • Peñaz, J.1
  • 4
    • 0026637505 scopus 로고
    • The reliability of noninvasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease
    • Bos WJW, Imholz BPM, van Goudoever J, Wesseling KH, van Montfrans GA. The reliability of noninvasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease. Am J Hypertens 1992; 5:529-535.
    • (1992) Am J Hypertens , vol.5 , pp. 529-535
    • Bos, W.J.W.1    Imholz, B.P.M.2    Van Goudoever, J.3    Wesseling, K.H.4    Van Montfrans, G.A.5
  • 6
    • 0024344783 scopus 로고
    • Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing
    • Parati G, Casadei R, Groppelli A, Di Rienzo M, Mancia G. Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing. Hypertension 1989; 13:647-655.
    • (1989) Hypertension , vol.13 , pp. 647-655
    • Parati, G.1    Casadei, R.2    Groppelli, A.3    Di Rienzo, M.4    Mancia, G.5
  • 8
    • 85047676115 scopus 로고
    • Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure
    • Imholz BPM, Settels JJ, van der Meieracker AH, Wesseling KH, Wieling W. Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure. Cardiovasc Res 1990; 24:214-221.
    • (1990) Cardiovasc Res , vol.24 , pp. 214-221
    • Imholz, B.P.M.1    Settels, J.J.2    Van Der Meieracker, A.H.3    Wesseling, K.H.4    Wieling, W.5
  • 10
    • 0021962995 scopus 로고
    • Effects of peripheral vasoconstriction on the blood pressure in the finger, measured continuously by a new noninvasive method (the Finapres)
    • Dorlas JC, Nijboer JA, Butijn WT, van der Hoeven GMA, Settles JJ, Wesseling KH. Effects of peripheral vasoconstriction on the blood pressure in the finger, measured continuously by a new noninvasive method (The Finapres). Anesthesiology 1985; 62:342-345.
    • (1985) Anesthesiology , vol.62 , pp. 342-345
    • Dorlas, J.C.1    Nijboer, J.A.2    Butijn, W.T.3    Van Der Hoeven, G.M.A.4    Settles, J.J.5    Wesseling, K.H.6
  • 11
    • 0021920324 scopus 로고
    • Invasive vs noninvasive measurement of arterial pressure, comparison of two automatic methods and simultaneously measured intra-arterial pressure
    • Egmond J, von Hasenbos M, Crul JF. Invasive vs noninvasive measurement of arterial pressure, comparison of two automatic methods and simultaneously measured intra-arterial pressure. Br J Anaesth 1985; 57:434-444.
    • (1985) Br J Anaesth , vol.57 , pp. 434-444
    • Egmond, J.1    Von Hasenbos, M.2    Crul, J.F.3
  • 12
    • 0029381955 scopus 로고
    • Underestimation of sensorimotor task-induced blood-pressure changes by posttask sphygmomanometry
    • Kugler J, Milau C, Traska T, Schmitz N, Krüskemper GM. Underestimation of sensorimotor task-induced blood-pressure changes by posttask sphygmomanometry. Perceptual and Motor Skills 1995; 81:483-490.
    • (1995) Perceptual and Motor Skills , vol.81 , pp. 483-490
    • Kugler, J.1    Milau, C.2    Traska, T.3    Schmitz, N.4    Krüskemper, G.M.5
  • 14
    • 0026135035 scopus 로고
    • On the usefulness of finger blood pressure measurements for studies on mental workload
    • Mulder LJM, Veldman JBP, Rueddel H, Robbe HWJ, Mulder G. On the usefulness of finger blood pressure measurements for studies on mental workload. Homeostasis 1991; 33:47-60.
    • (1991) Homeostasis , vol.33 , pp. 47-60
    • Mulder, L.J.M.1    Veldman, J.B.P.2    Rueddel, H.3    Robbe, H.W.J.4    Mulder, G.5
  • 15
    • 0342448573 scopus 로고
    • Application in psychophysiology of a non-invasive, continuous blood pressure measurement method
    • Godaert G. Application in psychophysiology of a non-invasive, continuous blood pressure measurement method. Homeostasis 1995; 36:130-138.
    • (1995) Homeostasis , vol.36 , pp. 130-138
    • Godaert, G.1
  • 16
    • 0006223151 scopus 로고
    • Beat-to-beat blood-pressure measurements applied in studies on mental workload
    • van Roon, Mulder AM, Veldman JBP, Mulder G. Beat-to-beat blood-pressure measurements applied in studies on mental workload. Homeostasis 1995; 36:316-324.
    • (1995) Homeostasis , vol.36 , pp. 316-324
    • Van Roon1    Mulder, A.M.2    Veldman, J.B.P.3    Mulder, G.4
  • 17
    • 0029058390 scopus 로고
    • Assessment of baroreflex control from beat-to-beat blood pressure and heart rate changes: A validation study
    • Watkins L, Fainman C, Dimsdale J, Ziegler M. Assessment of baroreflex control from beat-to-beat blood pressure and heart rate changes: a validation study. Psychophysiology 1995; 32:411-414.
    • (1995) Psychophysiology , vol.32 , pp. 411-414
    • Watkins, L.1    Fainman, C.2    Dimsdale, J.3    Ziegler, M.4
  • 18
    • 0027217119 scopus 로고
    • Measurement reliability of cardiovascular reactivity change scores: A comparison of intermittent and continuous methods of assessment
    • Gerin W, Pieper C, Pickering TG. Measurement reliability of cardiovascular reactivity change scores: a comparison of intermittent and continuous methods of assessment. J Psychosom Res 1993; 37:493-501.
    • (1993) J Psychosom Res , vol.37 , pp. 493-501
    • Gerin, W.1    Pieper, C.2    Pickering, T.G.3
  • 19
    • 0003181431 scopus 로고
    • 1983 Metropolitan height and weight tables
    • Metropolitan Life Foundation. 1983 Metropolitan height and weight tables. Stat Bull Metropol Insur C 1983; 64:1.
    • (1983) Stat Bull Metropol Insur C , vol.64 , pp. 1
  • 20
    • 0018875965 scopus 로고
    • Clinical evaluation of Dinamap 845 automated blood pressure recorder
    • Silas J, Barker A, Ramsay L. Clinical evaluation of Dinamap 845 automated blood pressure recorder. Br Heart J 1980; 43:202-205.
    • (1980) Br Heart J , vol.43 , pp. 202-205
    • Silas, J.1    Barker, A.2    Ramsay, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.