메뉴 건너뛰기




Volumn 113, Issue 3, 1998, Pages 612-618

Interpretive algorithms for the symptom-limited exercise test: Assessing dyspnea in Persian Gulf War Veterans

Author keywords

Clinical exercise testing; Dyspnea assessment; Persian Gulf War syndrome

Indexed keywords

ADULT; ALGORITHM; ARTICLE; BICYCLE ERGOMETRY; CLINICAL ARTICLE; DIAGNOSTIC VALUE; DYSPNEA; EXERCISE TEST; FEMALE; HUMAN; HUMAN CELL; HUMAN TISSUE; LUNG FUNCTION TEST; MALE; MILITARY MEDICINE; PRIORITY JOURNAL; WAR;

EID: 0031888821     PISSN: 00123692     EISSN: None     Source Type: Journal    
DOI: 10.1378/chest.113.3.612     Document Type: Article
Times cited : (8)

References (11)
  • 2
    • 0025177122 scopus 로고
    • An algorithm for the interpretation of cardiopulmonary exercise tests
    • Eschenbacher WL, Mannina A. An algorithm for the interpretation of cardiopulmonary exercise tests. Chest 1990; 97:263-67
    • (1990) Chest , vol.97 , pp. 263-267
    • Eschenbacher, W.L.1    Mannina, A.2
  • 3
    • 0029090616 scopus 로고
    • Standardization of spirometry
    • Official Statement of the ATS
    • Official Statement of the ATS. Standardization of spirometry. Am J Respir Crit Care Med 1995; 152:1107-36
    • (1995) Am J Respir Crit Care Med , vol.152 , pp. 1107-1136
  • 4
    • 6844245626 scopus 로고
    • Epidemiology Standardization Project. Am Rev Respir Dis 1978; 62-72, 77-80
    • (1978) Am Rev Respir Dis , pp. 62-72
  • 5
    • 0022542458 scopus 로고
    • A new method for detecting the anaerobic threshold by gas exchange
    • Beaver WL, Wasserman K, Whipp BJ. A new method for detecting the anaerobic threshold by gas exchange. J Appl Physiol 1986; 60:220-27
    • (1986) J Appl Physiol , vol.60 , pp. 220-227
    • Beaver, W.L.1    Wasserman, K.2    Whipp, B.J.3
  • 6
    • 0000195214 scopus 로고
    • Predicted values for clinical exercise testing
    • Hansen JE, Sue DY, Wasserman K. Predicted values for clinical exercise testing. Am Rev Respir Dis 1984; 140: 1373-80
    • (1984) Am Rev Respir Dis , vol.140 , pp. 1373-1380
    • Hansen, J.E.1    Sue, D.Y.2    Wasserman, K.3
  • 8
    • 0019457107 scopus 로고
    • Reference spirometric values using techniques and equipment that meet ATS recommendations
    • Crapo RO, Morris AH, Gardner RM. Reference spirometric values using techniques and equipment that meet ATS recommendations. Am Rev Respir Dis 1981; 123:659-64
    • (1981) Am Rev Respir Dis , vol.123 , pp. 659-664
    • Crapo, R.O.1    Morris, A.H.2    Gardner, R.M.3
  • 9
    • 0020574263 scopus 로고
    • Single breath diffusing capacity in a representative sample of the population of Michigan, a large industrial state
    • Miller A, Thornton JC, Warshaw R, et al. Single breath diffusing capacity in a representative sample of the population of Michigan, a large industrial state. Am Rev Respir Dis 1983; 127:270-77
    • (1983) Am Rev Respir Dis , vol.127 , pp. 270-277
    • Miller, A.1    Thornton, J.C.2    Warshaw, R.3
  • 10
    • 0016371823 scopus 로고
    • Ethnic differences in lung function: Evidence for proportional differences
    • Rossiter CE, Weill H. Ethnic differences in lung function: evidence for proportional differences. Int J Epidemiol 1974; 3:55-61
    • (1974) Int J Epidemiol , vol.3 , pp. 55-61
    • Rossiter, C.E.1    Weill, H.2
  • 11
    • 85030337344 scopus 로고
    • Accuracy of pulse oximetry in exercise testing
    • Yi S, Medinger A, Akin C, et al. Accuracy of pulse oximetry in exercise testing [abstract]. Am J Respir Crit Care Med 1995; 151:A663
    • (1995) Am J Respir Crit Care Med , vol.151
    • Yi, S.1    Medinger, A.2    Akin, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.