-
1
-
-
0028066060
-
Detection of beta-2 transferrin in otorrhea and rhinorrhea in a routine clinical laboratory setting
-
Normansell DE, Stacy EK, Booker CF, Butler TZ. Detection of beta-2 transferrin in otorrhea and rhinorrhea in a routine clinical laboratory setting. Clin Diagn Lab Immunol 1994;1:68-70.
-
(1994)
Clin Diagn Lab Immunol
, vol.1
, pp. 68-70
-
-
Normansell, D.E.1
Stacy, E.K.2
Booker, C.F.3
Butler, T.Z.4
-
3
-
-
0026914057
-
2-transferrin in cerebrospinal fluid to detect leakage of cerebrospinal fluid from skull injury
-
2-transferrin in cerebrospinal fluid to detect leakage of cerebrospinal fluid from skull injury. Clin Chem 1992;38:1909-12.
-
(1992)
Clin Chem
, vol.38
, pp. 1909-1912
-
-
Zaret, D.L.1
Morrison, N.2
Gulbranson, R.3
Keren, D.F.4
-
4
-
-
0025301493
-
Tau fraction of transferrin is present in human aqueous humor and is not unique to cerebrospinal fluid
-
Tripathi RC, Millard CB, Tripathi BJ, Noranhe A. Tau fraction of transferrin is present in human aqueous humor and is not unique to cerebrospinal fluid. Exp Eye Res 1990;50:541-7.
-
(1990)
Exp Eye Res
, vol.50
, pp. 541-547
-
-
Tripathi, R.C.1
Millard, C.B.2
Tripathi, B.J.3
Noranhe, A.4
-
5
-
-
0027749120
-
Beta-2 transferrin assay in clinical management of cerebral spinal fluid and perilymphatic fluid leaks
-
Skedros DG, Cass SP, Hirsch BE, Kelly RH. Beta-2 transferrin assay in clinical management of cerebral spinal fluid and perilymphatic fluid leaks. J Otolaryngol 1993;22:341-4.
-
(1993)
J Otolaryngol
, vol.22
, pp. 341-344
-
-
Skedros, D.G.1
Cass, S.P.2
Hirsch, B.E.3
Kelly, R.H.4
-
6
-
-
0029670795
-
Perilymph detection by β2-transferrin immunoblotting assay. Application to the diagnosis of perilymphatic fistulae
-
Delaroche O, Bordure P, Lippert E, Sagniez M. Perilymph detection by β2-transferrin immunoblotting assay. Application to the diagnosis of perilymphatic fistulae. Clin Chim Acta 1996;245:93-104.
-
(1996)
Clin Chim Acta
, vol.245
, pp. 93-104
-
-
Delaroche, O.1
Bordure, P.2
Lippert, E.3
Sagniez, M.4
-
7
-
-
0028933854
-
Correlation of beta-2 transferrin and middle ear abnormalities in congenital perilymphatic fistula
-
Weber PC. Bluestone CD, Kenna MA, Kelly RH. Correlation of beta-2 transferrin and middle ear abnormalities in congenital perilymphatic fistula. Am J Otol 1996;16:277-82.
-
(1996)
Am J Otol
, vol.16
, pp. 277-282
-
-
Weber, P.C.1
Bluestone, C.D.2
Kenna, M.A.3
Kelly, R.H.4
-
8
-
-
0026331891
-
Carbohydrate-deficient transferrin in serum: A new marker of potentially harmful alcohol consumption reviewed
-
Stibler H. Carbohydrate-deficient transferrin in serum: a new marker of potentially harmful alcohol consumption reviewed. Clin Chem 1991;37: 2029-37.
-
(1991)
Clin Chem
, vol.37
, pp. 2029-2037
-
-
Stibler, H.1
-
9
-
-
0027267260
-
Serum carbohydrate-deficient transferrin as a marker of alcohol consumption in patients with chronic liver diseases
-
Bell H, Tallaksen C, Sjåheim T, Weberg R, Raknerud N, Ørjasaeter H, et al. Serum carbohydrate-deficient transferrin as a marker of alcohol consumption in patients with chronic liver diseases. Alcohol Clin Exp Res 1993;17: 246-52.
-
(1993)
Alcohol Clin Exp Res
, vol.17
, pp. 246-252
-
-
Bell, H.1
Tallaksen, C.2
Sjåheim, T.3
Weberg, R.4
Raknerud, N.5
Ørjasaeter, H.6
-
11
-
-
0021686784
-
Sialic acid-deficient serum and cerebrospinal fluid transferrin in a newly recognized genetic syndrome
-
Jaeken J, van Eijk HG, van der Heul C, Corbeel L, Eeckels R, Eggermont E. Sialic acid-deficient serum and cerebrospinal fluid transferrin in a newly recognized genetic syndrome. Clin Chim Acta 1984;144:245-7.
-
(1984)
Clin Chim Acta
, vol.144
, pp. 245-247
-
-
Jaeken, J.1
Van Eijk, H.G.2
Van Der Heul, C.3
Corbeel, L.4
Eeckels, R.5
Eggermont, E.6
-
12
-
-
0027199336
-
Transferrin allelic variants may cause false positives in the detection of cerebrospinal fluid fistulae
-
Sloman AJ, Kelly RH. Transferrin allelic variants may cause false positives in the detection of cerebrospinal fluid fistulae. Clin Chem 1993;39:1444-5.
-
(1993)
Clin Chem
, vol.39
, pp. 1444-1445
-
-
Sloman, A.J.1
Kelly, R.H.2
-
14
-
-
84945033906
-
The diagnosis of CSF fistulae on the basis of detection of beta-2 transferrin by polyacrylamide gel electrophoresis and immunoblotting
-
Reisinger PWM, Hochstrasser K. The diagnosis of CSF fistulae on the basis of detection of beta-2 transferrin by polyacrylamide gel electrophoresis and immunoblotting. J Clin Chem Clin Biochem 1989;27:169-72.
-
(1989)
J Clin Chem Clin Biochem
, vol.27
, pp. 169-172
-
-
Reisinger, P.W.M.1
Hochstrasser, K.2
-
15
-
-
0025848840
-
Highly sensitive detection of beta-2 transferrin in rhinorrhea and otorrhea as a marker for cerebrospinal fluid leakage
-
Wien
-
Fransen P, Sindic CJM, Thauvoy C, Laterre C, Stroobandt G. Highly sensitive detection of beta-2 transferrin in rhinorrhea and otorrhea as a marker for cerebrospinal fluid leakage. Acta Neurochir (Wien) 1991;109:98-101.
-
(1991)
Acta Neurochir
, vol.109
, pp. 98-101
-
-
Fransen, P.1
Sindic, C.J.M.2
Thauvoy, C.3
Laterre, C.4
Stroobandt, G.5
|