External defibrillation: The need for uniformity in analyzing and reporting results

Author keywords

[No Author keywords available]

Indexed keywords

DATA ANALYSIS; DEFIBRILLATION; EDITORIAL; HEART RHYTHM; HEART VENTRICLE FIBRILLATION; OUTCOMES RESEARCH; PRIORITY JOURNAL;

EID: 0031880850     PISSN: 01960644     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0196-0644(98)70141-6     Document Type: Editorial
Times cited : (19)

References (14)
  • 1
    • 0032492753 scopus 로고    scopus 로고
    • American Heart Association report on the second public access defibrillation conference, April 17-19, 1997
    • G Nichol AP Hallstrom R Kerber American Heart Association report on the second public access defibrillation conference, April 17-19, 1997 Circulation 97 1998 1309 1314
    • (1998) Circulation , vol.97 , pp. 1309-1314
    • Nichol, G1    Hallstrom, AP2    Kerber, R3
  • 2
    • 0031904236 scopus 로고    scopus 로고
    • The effects of transthoracic impedance and peak current flow on defibrillation success in a prehospital setting
    • JP Heavens MJ Cleland JP Maloney The effects of transthoracic impedance and peak current flow on defibrillation success in a prehospital setting Ann Emerg Med 32 1998 191 199
    • (1998) Ann Emerg Med , vol.32 , pp. 191-199
    • Heavens, JP1    Cleland, MJ2    Maloney, JP3
  • 3
    • 85119800940 scopus 로고
    • Patients in ventricular fibrillation—predicted and actual transthoracic impedance and peak current at defibrillation [abstract]
    • SR Cunningham H Magee J Anderson Patients in ventricular fibrillation—predicted and actual transthoracic impedance and peak current at defibrillation [abstract] PACE 10 Pt II 1987 975
    • (1987) PACE , vol.10 , Issue.Pt II , pp. 975
    • Cunningham, SR1    Magee, H2    Anderson, J3
  • 4
    • 0021170163 scopus 로고
    • Advance prediction of transthoracic impedance in human defibrillation and cardioversion: Importance of impedance in determining the success of low-energy shocks
    • RE Kerber C Kouba J Martins Advance prediction of transthoracic impedance in human defibrillation and cardioversion: Importance of impedance in determining the success of low-energy shocks Circulation 70 1984 303 308
    • (1984) Circulation , vol.70 , pp. 303-308
    • Kerber, RE1    Kouba, C2    Martins, J3
  • 5
    • 0025812271 scopus 로고
    • Determinants of successful transthoracic defibrillation and outcome in ventrcular fibrillation
    • GWN Dalzell AAJ Adgey Determinants of successful transthoracic defibrillation and outcome in ventrcular fibrillation Br Heart J 65 1991 311 316
    • (1991) Br Heart J , vol.65 , pp. 311-316
    • Dalzell, GWN1    Adgey, AAJ2
  • 6
    • 0030330307 scopus 로고    scopus 로고
    • Truncated exponential versus damped sinusoidal waveform shocks for transthoracic defibrillation
    • JC Behr LL Hartley DK York Truncated exponential versus damped sinusoidal waveform shocks for transthoracic defibrillation Am J Cardiol 78 1996 1242 1245
    • (1996) Am J Cardiol , vol.78 , pp. 1242-1245
    • Behr, JC1    Hartley, LL2    York, DK3
  • 7
    • 0019946755 scopus 로고
    • Ventricular defibrillation—a comparative trial using 175-J and 320-J shocks
    • WD Weaver LA Cobb MK Copass Ventricular defibrillation—a comparative trial using 175-J and 320-J shocks N Engl J Med 307 1982 1101 1106
    • (1982) N Engl J Med , vol.307 , pp. 1101-1106
    • Weaver, WD1    Cobb, LA2    Copass, MK3
  • 8
    • 0031261114 scopus 로고    scopus 로고
    • Early out-of-hospital experience with an impedance-compensating low-energy biphasic waveform automatic external defibrillator
    • RD White Early out-of-hospital experience with an impedance-compensating low-energy biphasic waveform automatic external defibrillator J Int Cardiol Electrophysiol 1 1997 203 208
    • (1997) J Int Cardiol Electrophysiol , vol.1 , pp. 203-208
    • White, RD1
  • 9
    • 0032574673 scopus 로고    scopus 로고
    • Low-energy biphasic waveform defibrillation: Evidence-based review applied to emergency cardiovascular care guidelines
    • RO Cummins MF Hazinski RE Kerber Low-energy biphasic waveform defibrillation: Evidence-based review applied to emergency cardiovascular care guidelines Circulation 97 1998 1654 1667
    • (1998) Circulation , vol.97 , pp. 1654-1667
    • Cummins, RO1    Hazinski, MF2    Kerber, RE3
  • 10
    • 0022248708 scopus 로고
    • What is a “save”?: Outcome measures in clinical evaluations of automatic external defibrillations
    • RO Cummins MS Eisenberg AP Hallstrom What is a “save”?: Outcome measures in clinical evaluations of automatic external defibrillations Am Heart J 110 1985 1133 1138
    • (1985) Am Heart J , vol.110 , pp. 1133-1138
    • Cummins, RO1    Eisenberg, MS2    Hallstrom, AP3
  • 11
    • 0031918033 scopus 로고    scopus 로고
    • Effects of adding links to “the chain of survival” for prehospital cardiac arrest: A contrast in outcomes in 1975 and 1995 at a single institution
    • S Stratton JT Niemann Effects of adding links to “the chain of survival” for prehospital cardiac arrest: A contrast in outcomes in 1975 and 1995 at a single institution Ann Emerg Med 31 1998 471 477
    • (1998) Ann Emerg Med , vol.31 , pp. 471-477
    • Stratton, S1    Niemann, JT2
  • 12
    • 0008894185 scopus 로고    scopus 로고
    • Transthoracic impedance does not affect defibrillation efficacy in cardiac arrest victims when shocks are delivered with an impedance-compensating biphasic waveform
    • RD White BE Gliner Transthoracic impedance does not affect defibrillation efficacy in cardiac arrest victims when shocks are delivered with an impedance-compensating biphasic waveform Circulation 96 suppl 1997 1 561
    • (1997) Circulation , vol.96 , Issue.suppl , pp. 1-561
    • White, RD1    Gliner, BE2
  • 13
    • 15144353799 scopus 로고    scopus 로고
    • Low-energy impedance-compensating biphasic waveforms terminate ventricular fibrillation at high rates in victims of out-of-hospital cardiac arrest
    • JE Poole RD White K-G Kanz Low-energy impedance-compensating biphasic waveforms terminate ventricular fibrillation at high rates in victims of out-of-hospital cardiac arrest J Cardiovasc Electrophysiol 8 1997 1373 1385
    • (1997) J Cardiovasc Electrophysiol , vol.8 , pp. 1373-1385
    • Poole, JE1    White, RD2    Kanz, K-G3
  • 14
    • 0030812532 scopus 로고    scopus 로고
    • Estimating effectiveness of cardiac arrest interventions
    • TD Valenzuela DJ Roe S Cretin Estimating effectiveness of cardiac arrest interventions Circulation 96 1997 3308 3313
    • (1997) Circulation , vol.96 , pp. 3308-3313
    • Valenzuela, TD1    Roe, DJ2    Cretin, S3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.