메뉴 건너뛰기




Volumn 53, Issue 7, 1998, Pages 627-633

Anatomical variation of cerebral venous drainage: The theoretical effect on jugular bulb blood samples

Author keywords

Anatomy, cerebral venous drainage; Measurement techniques, magnetic resonance imaging; Oxygen, blood levels; Veins, jugular

Indexed keywords

ADULT; ANATOMY; ARTICLE; BLOOD SAMPLING; BRAIN BLOOD FLOW; BRAIN BLOOD VESSEL; FEMALE; HUMAN; HUMAN EXPERIMENT; JUGULAR VEIN; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PHLEBOGRAPHY; SUPERIOR SAGITTAL SINUS; VENOUS OXYGEN TENSION;

EID: 0031876947     PISSN: 00032409     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2044.1998.409-az0513.x     Document Type: Article
Times cited : (52)

References (19)
  • 1
    • 0026656473 scopus 로고
    • The effect of changes in cerebral perfusion pressure upon middle cerebral artery blood flow velocity and jugular bulb venous oxygen saturation after severe brain injury
    • Chan KH, Miller JD, Dearden NM, Andrews PJ, Midgley S. The effect of changes in cerebral perfusion pressure upon middle cerebral artery blood flow velocity and jugular bulb venous oxygen saturation after severe brain injury. Journal of Neurosurgery 1992; 77: 55-61.
    • (1992) Journal of Neurosurgery , vol.77 , pp. 55-61
    • Chan, K.H.1    Miller, J.D.2    Dearden, N.M.3    Andrews, P.J.4    Midgley, S.5
  • 2
    • 0029961108 scopus 로고    scopus 로고
    • Validation of the Edslab dual lumen oximetry catheter for continuous monitoring of jugular bulb oxygen saturation after severe head injury
    • Souter MJ, Andrews PJ. Validation of the Edslab dual lumen oximetry catheter for continuous monitoring of jugular bulb oxygen saturation after severe head injury. British Journal of Anaesthesia 1996; 76: 744-6.
    • (1996) British Journal of Anaesthesia , vol.76 , pp. 744-746
    • Souter, M.J.1    Andrews, P.J.2
  • 3
    • 0023503913 scopus 로고
    • The use of intermittent and continuous recordings of jugular venous bulb oxygen saturation in the unconscious patient
    • Garlick R, Bihari D. The use of intermittent and continuous recordings of jugular venous bulb oxygen saturation in the unconscious patient. Scandinavian Journal of Clinical Laboratory Investigation 1987; 188: 47-52.
    • (1987) Scandinavian Journal of Clinical Laboratory Investigation , vol.188 , pp. 47-52
    • Garlick, R.1    Bihari, D.2
  • 4
    • 0029848163 scopus 로고    scopus 로고
    • Monitoring of cerebral oxygenation in patients with severe head injuries: Brain tissue PO2 versus jugular vein oxygen saturation
    • Kiening KL, Unterberg AW, Bardt TF, Schneider GH, Lanksch WR. Monitoring of cerebral oxygenation in patients with severe head injuries: brain tissue PO2 versus jugular vein oxygen saturation. Journal of Neurosurgery 1996; 85: 751-7.
    • (1996) Journal of Neurosurgery , vol.85 , pp. 751-757
    • Kiening, K.L.1    Unterberg, A.W.2    Bardt, T.F.3    Schneider, G.H.4    Lanksch, W.R.5
  • 5
    • 0027757506 scopus 로고
    • Technical considerations in continuous jugular venous oxygen saturation measurement
    • Dearden NM, Midgley S. Technical considerations in continuous jugular venous oxygen saturation measurement. Acta Neurochirurgica (Wien) 1993; 59: 91-7.
    • (1993) Acta Neurochirurgica (Wien) , vol.59 , pp. 91-97
    • Dearden, N.M.1    Midgley, S.2
  • 6
    • 0002783323 scopus 로고
    • Cerebral blood flow
    • Sebel P, Fitch W, eds. Oxford: Blackwell Science Ltd
    • Fitch W. Cerebral blood flow. In: Sebel P, Fitch W, eds. Monitoring the Central Nervous System. Oxford: Blackwell Science Ltd, 1994; 78-117.
    • (1994) Monitoring the Central Nervous System , pp. 78-117
    • Fitch, W.1
  • 7
  • 8
    • 0028208995 scopus 로고
    • Continuous measurement of jugular venous oxygen saturation in response to transient elevations of blood pressure in head-injured patients
    • Fortune JB, Feustel PJ, Weigle CG, Popp AJ. Continuous measurement of jugular venous oxygen saturation in response to transient elevations of blood pressure in head-injured patients. Journal of Neurosurgery 1994; 80: 461-8.
    • (1994) Journal of Neurosurgery , vol.80 , pp. 461-468
    • Fortune, J.B.1    Feustel, P.J.2    Weigle, C.G.3    Popp, A.J.4
  • 9
    • 2642641088 scopus 로고
    • Intracranial pressure measurement
    • Sebel P, Fitch W, eds. Oxford: Blackwell Science Ltd
    • Bullock R. Intracranial pressure measurement. In: Sebel P, Fitch W, eds. Monitoring the Central Nervous System. Oxford: Blackwell Science Ltd, 1994; 117-152.
    • (1994) Monitoring the Central Nervous System , pp. 117-152
    • Bullock, R.1
  • 10
    • 0029014677 scopus 로고
    • Continuous monitoring of jugular bulb oxygen saturation in comatose patients - Therapeutic implications
    • Schneider GH, von Helden A, Lanksch WR, Unterberg A. Continuous monitoring of jugular bulb oxygen saturation in comatose patients - therapeutic implications. Acta Neurochirurgica (Wien) 1995; 134: 71-5.
    • (1995) Acta Neurochirurgica (Wien) , vol.134 , pp. 71-75
    • Schneider, G.H.1    Von Helden, A.2    Lanksch, W.R.3    Unterberg, A.4
  • 11
    • 0026542001 scopus 로고
    • Continuous monitoring of jugular venous oxygen saturation in head-injured patients
    • Sheinberg M, Kanter MJ, Robertson CS, et al. Continuous monitoring of jugular venous oxygen saturation in head-injured patients. Journal of Neurosurgery 1992; 76: 212-7.
    • (1992) Journal of Neurosurgery , vol.76 , pp. 212-217
    • Sheinberg, M.1    Kanter, M.J.2    Robertson, C.S.3
  • 12
    • 0029761293 scopus 로고    scopus 로고
    • Cerebral venous oxygen saturation monitoring: Is dominant jugular bulb cannulation good enough?
    • Lam JM, Chan MS, Poon WS. Cerebral venous oxygen saturation monitoring: is dominant jugular bulb cannulation good enough? British Journal of Neurosurgery 1996; 10: 357-64.
    • (1996) British Journal of Neurosurgery , vol.10 , pp. 357-364
    • Lam, J.M.1    Chan, M.S.2    Poon, W.S.3
  • 13
    • 0015194205 scopus 로고
    • Cerebral blood flow, jugular venous PO2 and lactate concentration and arterial venous oxygen content during carotid endarterectomy
    • Waltz A, Sundt T, Michenfelder J. Cerebral blood flow, jugular venous PO2 and lactate concentration and arterial venous oxygen content during carotid endarterectomy. European Neurology 1971; 6: 346-9.
    • (1971) European Neurology , vol.6 , pp. 346-349
    • Waltz, A.1    Sundt, T.2    Michenfelder, J.3
  • 14
    • 0028009422 scopus 로고
    • Cerebral venous oxygen saturation studied with bilateral samples in the internal jugular veins
    • Stocchetti N, Paparella A, Bridelli F, et al Cerebral venous oxygen saturation studied with bilateral samples in the internal jugular veins. Neurosurgery 1994; 34: 38-43.
    • (1994) Neurosurgery , vol.34 , pp. 38-43
    • Stocchetti, N.1    Paparella, A.2    Bridelli, F.3
  • 15
    • 84973435122 scopus 로고
    • Differences in bilateral jugular bulb oxygen saturation values in severe head injured patients
    • Triginer C, Robles A, Baguena M, et al. Differences in bilateral jugular bulb oxygen saturation values in severe head injured patients. Intensive Care Medicine 1995; 21 (S1): 51.
    • (1995) Intensive Care Medicine , vol.21 , Issue.S1 , pp. 51
    • Triginer, C.1    Robles, A.2    Baguena, M.3
  • 18
    • 0026721283 scopus 로고
    • MR angiography of the head and neck: Value of two-dimensional phase-contrast projection technique
    • Applegate GR, Talagala SL, Applegate LJ. MR angiography of the head and neck: value of two-dimensional phase-contrast projection technique. American Journal of Roentgenology 1992; 159: 369-74.
    • (1992) American Journal of Roentgenology , vol.159 , pp. 369-374
    • Applegate, G.R.1    Talagala, S.L.2    Applegate, L.J.3
  • 19


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.