메뉴 건너뛰기




Volumn 47, Issue 7, 1998, Pages 799-803

Continuous glucose monitoring in the free-moving rat

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL MODEL; ARTICLE; BIOSENSOR; BLOOD GLUCOSE MONITORING; CONTROLLED STUDY; DEVICE; DIAGNOSTIC VALUE; GLUCOSE BLOOD LEVEL; HYPERGLYCEMIA; HYPERINSULINEMIA; HYPOGLYCEMIA; HYPOINSULINEMIA; NONHUMAN; PRIORITY JOURNAL; RAT; TECHNIQUE;

EID: 0031863988     PISSN: 00260495     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0026-0495(98)90115-9     Document Type: Article
Times cited : (16)

References (15)
  • 1
    • 2742571808 scopus 로고
    • Continuous glucose monitoring with a subcutaneous sensor. Rationale, requirements and achievements, and prospectives
    • Reach G: Continuous glucose monitoring with a subcutaneous sensor. Rationale, requirements and achievements, and prospectives. Diabetes Ann 7:332-348, 1993
    • (1993) Diabetes Ann , vol.7 , pp. 332-348
    • Reach, G.1
  • 2
    • 0002245404 scopus 로고
    • Glucose sensors and closed-loop insulin delivery
    • Pickup J (ed): Oxford, UK, Blackwell Scientific
    • Pickup J: Glucose sensors and closed-loop insulin delivery, in Pickup J (ed): Biotechnology of Insulin Therapy. Oxford, UK, Blackwell Scientific, 1991, pp 126-153
    • (1991) Biotechnology of Insulin Therapy , pp. 126-153
    • Pickup, J.1
  • 3
    • 0026216348 scopus 로고
    • Design and in vitro studies of a needle type glucose sensor for subcutaneous monitoring
    • Bindra DS, Zhang Y, Wilson GS, et al: Design and in vitro studies of a needle type glucose sensor for subcutaneous monitoring. Anal Chem 63:1692-1696, 1991
    • (1991) Anal Chem , vol.63 , pp. 1692-1696
    • Bindra, D.S.1    Zhang, Y.2    Wilson, G.S.3
  • 4
    • 0027236355 scopus 로고
    • In vitro and in vivo evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor
    • Zhang Y, Wilson GS: In vitro and in vivo evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor. Anal Chim Acta 281:513-520, 1993
    • (1993) Anal Chim Acta , vol.281 , pp. 513-520
    • Zhang, Y.1    Wilson, G.S.2
  • 5
    • 0028418786 scopus 로고
    • Elimination of acetaminophen interference in an implantable glucose sensor
    • Zhang Y, Hu Y, Wilson GS, et al: Elimination of acetaminophen interference in an implantable glucose sensor. Anal Chem 66:1183-1188, 1994
    • (1994) Anal Chem , vol.66 , pp. 1183-1188
    • Zhang, Y.1    Hu, Y.2    Wilson, G.S.3
  • 6
    • 0026590041 scopus 로고
    • Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor
    • Moatti-Sirat D, Velho G, Reach G: Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor. Biosensors Bioelectron 7:345-352, 1992
    • (1992) Biosensors Bioelectron , vol.7 , pp. 345-352
    • Moatti-Sirat, D.1    Velho, G.2    Reach, G.3
  • 7
    • 0028272196 scopus 로고
    • Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: Demonstration in rats and man
    • Moatti-Sirat D, Poitout V, Thomé V, et al: Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: Demonstration in rats and man. Diabetologia 37:610-616, 1994
    • (1994) Diabetologia , vol.37 , pp. 610-616
    • Moatti-Sirat, D.1    Poitout, V.2    Thomé, V.3
  • 8
    • 0026546742 scopus 로고
    • Towards continuous glucose monitoring: In vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue
    • Moatti-Sirat D, Capron F, Poitout V, et al: Towards continuous glucose monitoring: In vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Diabetologia 35:224-230, 1992
    • (1992) Diabetologia , vol.35 , pp. 224-230
    • Moatti-Sirat, D.1    Capron, F.2    Poitout, V.3
  • 9
    • 0026491971 scopus 로고
    • Calibration in dogs of subcutaneous miniaturised glucose sensor using a glucose meter for blood glucose determination
    • Poitout V, Moatti-Sirat D, Reach G: Calibration in dogs of subcutaneous miniaturised glucose sensor using a glucose meter for blood glucose determination. Biosensors Bioelectron 7:587-592, 1992
    • (1992) Biosensors Bioelectron , vol.7 , pp. 587-592
    • Poitout, V.1    Moatti-Sirat, D.2    Reach, G.3
  • 10
    • 0026192568 scopus 로고
    • In vivo evaluation of a glucose sensor implanted in the subcutaneous tissue of conscious dogs
    • Poitout V, Moatti-Sirat D, Velho G, et al: In vivo evaluation of a glucose sensor implanted in the subcutaneous tissue of conscious dogs. Trans Am Soc Artif Intern Organs 37:M298-M300, 1991
    • (1991) Trans Am Soc Artif Intern Organs , vol.37
    • Poitout, V.1    Moatti-Sirat, D.2    Velho, G.3
  • 11
    • 0027214964 scopus 로고
    • A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturised glucose sensor implanted in the subcutaneous tissue, and a wearable control unit
    • Poitout V, Moatti-Sirat D, Reach G, et al: A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturised glucose sensor implanted in the subcutaneous tissue, and a wearable control unit. Diabetologia 36:658-663, 1993
    • (1993) Diabetologia , vol.36 , pp. 658-663
    • Poitout, V.1    Moatti-Sirat, D.2    Reach, G.3
  • 12
    • 2742550992 scopus 로고
    • High performances portable electronic device for continuous blood glucose monitoring
    • abstr
    • Klein JC, Lemonnier F, Thomé V, et al: High performances portable electronic device for continuous blood glucose monitoring. Horm Metab Res 27:58, 1995 (abstr)
    • (1995) Horm Metab Res , vol.27 , pp. 58
    • Klein, J.C.1    Lemonnier, F.2    Thomé, V.3
  • 13
    • 0018731152 scopus 로고
    • The effect of streptozotocin on the pancreatic A cell function
    • Kazumi T, Yoshino G, Monta S, et al: The effect of streptozotocin on the pancreatic A cell function. Endocrinol J 26:331-335, 1979
    • (1979) Endocrinol J , vol.26 , pp. 331-335
    • Kazumi, T.1    Yoshino, G.2    Monta, S.3
  • 14
    • 0024243378 scopus 로고
    • In vivo calibration of a subcutaneous glucose sensor for determination of subcutaneous glucose kinetics
    • Velho G, Froguel P, Thévenot DR, et al: In vivo calibration of a subcutaneous glucose sensor for determination of subcutaneous glucose kinetics. Diabetes Nutr Metab Clin Exp 1:227-233, 1988
    • (1988) Diabetes Nutr Metab Clin Exp , vol.1 , pp. 227-233
    • Velho, G.1    Froguel, P.2    Thévenot, D.R.3
  • 15
    • 0028871133 scopus 로고
    • Excessive glucose production, rather than insulin resistance, accounts for hyperglycaemia in recent-onset streptozotocin-diabetic rats
    • Burcelin R, Kande J, Eddouks M, et al: Excessive glucose production, rather than insulin resistance, accounts for hyperglycaemia in recent-onset streptozotocin-diabetic rats. Diabetologia 38:283-290, 1995
    • (1995) Diabetologia , vol.38 , pp. 283-290
    • Burcelin, R.1    Kande, J.2    Eddouks, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.