메뉴 건너뛰기




Volumn 207, Issue 2, 1998, Pages 331-337

MR imaging of the liver: Comparison between single-shot echo-planar and half-Fourier rapid acquisition with relaxation enhancement sequences

Author keywords

Liver neoplasms, MR; Magnetic resonance (MR), echo planar; Magnetic resonance (MR), pulse sequences; Magnetic resonance (MR), rapid imaging

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT; BILE DUCT CARCINOMA; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; FOURIER ANALYSIS; HUMAN; IMAGE QUALITY; LIVER CELL CARCINOMA; LIVER HEMANGIOMA; LIVER METASTASIS; LIVER TUMOR; LYMPHOMA; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; SIGNAL NOISE RATIO;

EID: 0031862271     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.207.2.9577477     Document Type: Article
Times cited : (22)

References (19)
  • 1
    • 0027957235 scopus 로고
    • Abdominal MR imaging: Evaluation of a fast spin-echo sequence
    • Outwater EK, Mitchell DG, Vinitski S. Abdominal MR imaging: evaluation of a fast spin-echo sequence. Radiology 1994; 190:425-429.
    • (1994) Radiology , vol.190 , pp. 425-429
    • Outwater, E.K.1    Mitchell, D.G.2    Vinitski, S.3
  • 2
    • 0027567036 scopus 로고
    • T2-weighted MR imaging of focal hepatic lesions: Comparison of various RARE and fat-suppressed spin-echo sequences
    • Semelka RC, Shoenut JP, Kroeker RM. T2-weighted MR imaging of focal hepatic lesions: comparison of various RARE and fat-suppressed spin-echo sequences. JMRI 1993; 3:323-327.
    • (1993) JMRI , vol.3 , pp. 323-327
    • Semelka, R.C.1    Shoenut, J.P.2    Kroeker, R.M.3
  • 3
    • 0029992649 scopus 로고    scopus 로고
    • The value of MR urography that uses HASTE sequences to reveal urinary tract disorders
    • Tan Y, Yamashita Y, Namimoto T, et al. The value of MR urography that uses HASTE sequences to reveal urinary tract disorders. AJR 1996; 167:1497-1502.
    • (1996) AJR , vol.167 , pp. 1497-1502
    • Tan, Y.1    Yamashita, Y.2    Namimoto, T.3
  • 4
    • 0022872540 scopus 로고
    • RARE imaging: A fast imaging method for clinical MR
    • Hennig J, Naureth A, Friedburg H. RARE imaging: a fast imaging method for clinical MR. Magn Reson Med 1986; 3:823-833.
    • (1986) Magn Reson Med , vol.3 , pp. 823-833
    • Hennig, J.1    Naureth, A.2    Friedburg, H.3
  • 5
    • 0029953063 scopus 로고    scopus 로고
    • Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging
    • Gaa J, Hatabu H, Jenkins R, Finn J, Edelman R. Liver masses: replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging. Radiology 1996; 200:459-464.
    • (1996) Radiology , vol.200 , pp. 459-464
    • Gaa, J.1    Hatabu, H.2    Jenkins, R.3    Finn, J.4    Edelman, R.5
  • 6
    • 0029904406 scopus 로고    scopus 로고
    • MR cholangiopancreatography using HASTE (half-Fourier acquisition single-shot turbo spin-echo) sequences
    • Miyazaki T, Yamashita Y, Tsuchigame T, Yamamoto H, Urata J, Takahashi M. MR cholangiopancreatography using HASTE (half-Fourier acquisition single-shot turbo spin-echo) sequences. AJR 1996; 166:1297-1303.
    • (1996) AJR , vol.166 , pp. 1297-1303
    • Miyazaki, T.1    Yamashita, Y.2    Tsuchigame, T.3    Yamamoto, H.4    Urata, J.5    Takahashi, M.6
  • 8
    • 0027299367 scopus 로고
    • Value of T1 and T2 relaxation times from echo planar MR imaging in the characterization of focal hepatic lesions
    • Goldberg MA, Hahn PF, Sauni S, et al. Value of T1 and T2 relaxation times from echo planar MR imaging in the characterization of focal hepatic lesions. AJR 1993; 160:1011-1017.
    • (1993) AJR , vol.160 , pp. 1011-1017
    • Goldberg, M.A.1    Hahn, P.F.2    Sauni, S.3
  • 9
    • 0028567893 scopus 로고
    • Echoplanar MR imaging of the liver in patients with focal hepatic lesions: Quantitative analysis of images made with various pulse sequences
    • Saini S, Reimer P, Hahn PF, Cohen MS. Echoplanar MR imaging of the liver in patients with focal hepatic lesions: quantitative analysis of images made with various pulse sequences. AJR 1994; 163:1389-1393.
    • (1994) AJR , vol.163 , pp. 1389-1393
    • Saini, S.1    Reimer, P.2    Hahn, P.F.3    Cohen, M.S.4
  • 11
    • 0030021798 scopus 로고    scopus 로고
    • T2-weighted spin-echo MR imaging of the liver: Breath-hold fast spin-echo versus non-breath-hold fast spin-echo images with and without fat suppression
    • Soyer P, Normand SL, Givry SC, et al. T2-weighted spin-echo MR imaging of the liver: breath-hold fast spin-echo versus non-breath-hold fast spin-echo images with and without fat suppression. AJR 1996; 166:593-597.
    • (1996) AJR , vol.166 , pp. 593-597
    • Soyer, P.1    Normand, S.L.2    Givry, S.C.3
  • 12
    • 0028796848 scopus 로고
    • Comparison of breath-hold fast spin-echo and conventional spin-echo pulse sequences for T2-weighted MR imaging of liver lesions
    • Rydberg JN, Lomas DJ, Coakley KJ, Hough DM, Ehman R, Riederer SJ. Comparison of breath-hold fast spin-echo and conventional spin-echo pulse sequences for T2-weighted MR imaging of liver lesions. Radiology 1995; 194:431-437.
    • (1995) Radiology , vol.194 , pp. 431-437
    • Rydberg, J.N.1    Lomas, D.J.2    Coakley, K.J.3    Hough, D.M.4    Ehman, R.5    Riederer, S.J.6
  • 13
    • 0027320801 scopus 로고
    • Echo-planar perfusion-sensitive MR imaging of acute cerebral ischemia
    • Kucharczk J, Vexler ZS, Robers TP, et al. Echo-planar perfusion-sensitive MR imaging of acute cerebral ischemia. Radiology 1993; 188:711-717.
    • (1993) Radiology , vol.188 , pp. 711-717
    • Kucharczk, J.1    Vexler, Z.S.2    Robers, T.P.3
  • 15
    • 0026691290 scopus 로고
    • MR diffusion imaging of cerebral infarction in humans
    • Chien D, Kwong KK, Gress DR, et al. MR diffusion imaging of cerebral infarction in humans. AJNR 1992; 13:1097-1102.
    • (1992) AJNR , vol.13 , pp. 1097-1102
    • Chien, D.1    Kwong, K.K.2    Gress, D.R.3
  • 16
    • 0026761501 scopus 로고
    • Fast magnetic resonance diffusion-weighted imaging of acute human stroke
    • Warach S, Chien D, Li W, et al. Fast magnetic resonance diffusion-weighted imaging of acute human stroke. Neurology 1992; 42:1717-1723.
    • (1992) Neurology , vol.42 , pp. 1717-1723
    • Warach, S.1    Chien, D.2    Li, W.3
  • 17
    • 0025096086 scopus 로고
    • The clinical application of echo planar imaging in neuroradiology
    • Worthington BS, Mansfield P. The clinical application of echo planar imaging in neuroradiology. Neuroradiology 1990; 32: 367-370.
    • (1990) Neuroradiology , vol.32 , pp. 367-370
    • Worthington, B.S.1    Mansfield, P.2
  • 18
    • 0030183194 scopus 로고    scopus 로고
    • HASTE MR imaging: Description of technique and preliminary results in the abdomen
    • Semelka RC, Kelekis NL, Thomasson D, et al. HASTE MR imaging: description of technique and preliminary results in the abdomen. JMRI 1996; 6:698-699.
    • (1996) JMRI , vol.6 , pp. 698-699
    • Semelka, R.C.1    Kelekis, N.L.2    Thomasson, D.3
  • 19
    • 0031001798 scopus 로고    scopus 로고
    • Liver T2-weighted MR imaging: Comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences
    • Tang Y, Yamashita Y, Namimoto T, Abe Y, Takahashi M. Liver T2-weighted MR imaging: comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences. Radiology 1997; 203:766-772.
    • (1997) Radiology , vol.203 , pp. 766-772
    • Tang, Y.1    Yamashita, Y.2    Namimoto, T.3    Abe, Y.4    Takahashi, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.