메뉴 건너뛰기




Volumn 40, Issue 2, 1998, Pages 334-340

Single-shot, variable flip-angle slice-selective excitation with four gradient-modulated adiabatic half-passage segments

Author keywords

Adiabatic pulses; Gradient modulated selective excitation; Single shot

Indexed keywords

ADIABATIC PULSE; B1 FIELD; EXPERIMENTAL TEST; FLIP ANGLE; NMR-IMAGING; SELECTIVE EXCITATIONS; SINGLE SHOTS; SLICE-SELECTIVE EXCITATIONS;

EID: 0031858555     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910400220     Document Type: Article
Times cited : (5)

References (13)
  • 2
    • 0024528859 scopus 로고
    • Magnetic resonance imaging with adiabatic pulses using a single surface coil for RF transmission and signal detection
    • M. Garwood, K. Ugurbil, A. R. Rath, M. R. Bendall, B. D. Ross, S. L. Mitchell, H. Merkte, Magnetic resonance imaging with adiabatic pulses using a single surface coil for RF transmission and signal detection. Magn. Reson. Med. 9, 25-34 (1989).
    • (1989) Magn. Reson. Med. , vol.9 , pp. 25-34
    • Garwood, M.1    Ugurbil, K.2    Rath, A.R.3    Bendall, M.R.4    Ross, B.D.5    Mitchell, S.L.6    Merkte, H.7
  • 5
    • 0029665944 scopus 로고    scopus 로고
    • 1 -insensitive slice selection with a gradient-modulated adiabatic pulse, BISS-8
    • 1 -insensitive slice selection with a gradient-modulated adiabatic pulse, BISS-8. Magn. Reson. Med. 35, 652-657 (1996).
    • (1996) Magn. Reson. Med. , vol.35 , pp. 652-657
    • De Graaf, R.A.1    Nicolay, K.2    Garwood, M.3
  • 7
    • 0030634087 scopus 로고    scopus 로고
    • Adiabatic slice-selective excitation for surface coils
    • J. Shen, D. L. Rothman, Adiabatic slice-selective excitation for surface coils. J. Magn. Reson. 124, 72-79 (1997].
    • (1997) J. Magn. Reson. , vol.124 , pp. 72-79
    • Shen, J.1    Rothman, D.L.2
  • 8
    • 0001230743 scopus 로고
    • Optimization of modulation functions to improve insensitivity of adiabatic pulses to variations in B1 magnitude
    • K. Ugurbil, M. Garwood, A. R. Rath. Optimization of modulation functions to improve insensitivity of adiabatic pulses to variations in B1 magnitude. J. Magn. Reson. 80, 448-469 (1988).
    • (1988) J. Magn. Reson. , vol.80 , pp. 448-469
    • Ugurbil, K.1    Garwood, M.2    Rath, A.R.3
  • 10
    • 0009578882 scopus 로고
    • General solutions for tailored modulation profiles in adiabatic excitation
    • T. E. Skinner, P. L. Robitaille, General solutions for tailored modulation profiles in adiabatic excitation. J. Magn. Reson. 98, 14-23 (1992).
    • (1992) J. Magn. Reson. , vol.98 , pp. 14-23
    • Skinner, T.E.1    Robitaille, P.L.2
  • 11
    • 0000367695 scopus 로고
    • Composite pulses constructed by a recursive expansion procedure
    • M. H. Levitt, R. R. Ernst, Composite pulses constructed by a recursive expansion procedure. J. Magn. Reson. 55, 247-254 (1983).
    • (1983) J. Magn. Reson. , vol.55 , pp. 247-254
    • Levitt, M.H.1    Ernst, R.R.2
  • 12
    • 44949273876 scopus 로고
    • Symmetric pulses to induce arbitrary flip angles with compensation for RF inhomogeneity and resonance offsets
    • M. Garwood, Y. Ke, Symmetric pulses to induce arbitrary flip angles with compensation for RF inhomogeneity and resonance offsets. J. Magn. Reson. 94, 511-525 (1991).
    • (1991) J. Magn. Reson. , vol.94 , pp. 511-525
    • Garwood, M.1    Ke, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.