-
2
-
-
0026346472
-
Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components
-
Collier JP, Mayor MB, McNamara JL, Surprenant VA, Jensen RE. Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin Orthop 1991;273:232-242.
-
(1991)
Clin Orthop
, vol.273
, pp. 232-242
-
-
Collier, J.P.1
Mayor, M.B.2
McNamara, J.L.3
Surprenant, V.A.4
Jensen, R.E.5
-
3
-
-
0026527293
-
Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses
-
Engh GA, Dwyer KA, Hanes CK. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Jt Surg Br Vol 1992;74B:9-17.
-
(1992)
J Bone Jt Surg Br Vol
, vol.74 B
, pp. 9-17
-
-
Engh, G.A.1
Dwyer, K.A.2
Hanes, C.K.3
-
4
-
-
0020826593
-
Retrieval analysis of total knee prosthesis: A method and its application to 48 total condylar prosthesis
-
Hood RW, Wright TM, Burstein AH. Retrieval analysis of total knee prosthesis: a method and its application to 48 total condylar prosthesis. J Biomed Mater Res 1983;17:829-842.
-
(1983)
J Biomed Mater Res
, vol.17
, pp. 829-842
-
-
Hood, R.W.1
Wright, T.M.2
Burstein, A.H.3
-
6
-
-
0026356990
-
Catastrophic wear of tibial polyethylene inserts
-
Kilgus DJ, Moreland JR, Finerrnan GAM, Funahashi TT, Tipton JS. Catastrophic wear of tibial polyethylene inserts. Clin Orthop 1991;273:223-231.
-
(1991)
Clin Orthop
, vol.273
, pp. 223-231
-
-
Kilgus, D.J.1
Moreland, J.R.2
Finerrnan, G.A.M.3
Funahashi, T.T.4
Tipton, J.S.5
-
7
-
-
0023697318
-
Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses
-
Landy MM, Walker PS. Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses. J Arthroplasty 1988;8:S73-S85.
-
(1988)
J Arthroplasty
, vol.8
-
-
Landy, M.M.1
Walker, P.S.2
-
8
-
-
0017966550
-
The appearances of wear on polyethylene - a comparison of in vivo and in vitro wear surfaces
-
Rostoker W, Chao EYS, Galante JO. The appearances of wear on polyethylene - a comparison of in vivo and in vitro wear surfaces. J Biomed Mater Res 1978;12:317-335.
-
(1978)
J Biomed Mater Res
, vol.12
, pp. 317-335
-
-
Rostoker, W.1
Chao, E.Y.S.2
Galante, J.O.3
-
9
-
-
0027972449
-
Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty
-
Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop 1994;299:31-43.
-
(1994)
Clin Orthop
, vol.299
, pp. 31-43
-
-
Wasielewski, R.C.1
Galante, J.O.2
Leighty, R.M.3
Natarajan, R.N.4
Rosenberg, A.G.5
-
10
-
-
0021897233
-
Retrieval analysis of total joint replacement components: A six-year experience
-
Fraker AC, Griffin CD, editors. STP
-
Wright TM, Burstein AH, Bartel DL. Retrieval analysis of total joint replacement components: a six-year experience. In: Fraker AC, Griffin CD, editors. Corrosion and degradation of implant materials: Second Symposium ASTM. STP 1985;859:415-428
-
(1985)
Corrosion and Degradation of Implant Materials: Second Symposium ASTM
, vol.859
, pp. 415-428
-
-
Wright, T.M.1
Burstein, A.H.2
Bartel, D.L.3
-
11
-
-
0022504260
-
The problem of surface damage in polyethylene total knee components
-
Wright TM, Bartel DL. The problem of surface damage in polyethylene total knee components. Clin Orthop 1986;205:67-74.
-
(1986)
Clin Orthop
, vol.205
, pp. 67-74
-
-
Wright, T.M.1
Bartel, D.L.2
-
12
-
-
0026589837
-
Wear of polyethylene in total joint replacements: Observations from retrieved PCA knee implants
-
Wright TM, Rimnac CM, Stulberg SD et al. Wear of polyethylene in total joint replacements: observations from retrieved PCA knee implants. Clin Orthop 1992;275:126-134.
-
(1992)
Clin Orthop
, vol.275
, pp. 126-134
-
-
Wright, T.M.1
Rimnac, C.M.2
Stulberg, S.D.3
-
14
-
-
0012733135
-
Effects of metal-backing surface finish and relative motion on wear of the distal polyethylene surface in total knee replacement components
-
Gabriel SM, Dennis DA. Effects of metal-backing surface finish and relative motion on wear of the distal polyethylene surface in total knee replacement components. Trans Comb ORS 1995;114.
-
(1995)
Trans Comb ORS
, pp. 114
-
-
Gabriel, S.M.1
Dennis, D.A.2
-
15
-
-
0028245867
-
Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
-
Huk OL, Bansal M, Betts F et al. Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J Bone Jt Surg Br Vol 1994;76B:568-574.
-
(1994)
J Bone Jt Surg Br Vol
, vol.76 B
, pp. 568-574
-
-
Huk, O.L.1
Bansal, M.2
Betts, F.3
-
18
-
-
0018431399
-
Wear mechanisms for ultrahigh molecular weight polyethylene in the total hip prostheses
-
Nusbaum HJ, Rose RM, Paul IL, Crugnola AM, Radin EL. Wear mechanisms for ultrahigh molecular weight polyethylene in the total hip prostheses. J Appl Pol Sci 1979;23:777-789.
-
(1979)
J Appl Pol Sci
, vol.23
, pp. 777-789
-
-
Nusbaum, H.J.1
Rose, R.M.2
Paul, I.L.3
Crugnola, A.M.4
Radin, E.L.5
-
19
-
-
0028836831
-
The origin of submicron polyethylene wear debris in total hip arthroplasty
-
McKellop HA, Campbell P, Park S-H et al. The origin of submicron polyethylene wear debris in total hip arthroplasty. Clin Orthop 1995;311:3-20.
-
(1995)
Clin Orthop
, vol.311
, pp. 3-20
-
-
McKellop, H.A.1
Campbell, P.2
Park, S.-H.3
|