메뉴 건너뛰기




Volumn 208, Issue 2, 1998, Pages 296-299

Advances in perfusion MR imaging

Author keywords

Cerebral blood vessels, flow dynamics; Editorials; Magnetic resonance (MR), echo planar; Magnetic resonance (MR), perfusion study; Magnetic resonance (MR), vascular studies

Indexed keywords

BLOOD FLOW VELOCITY; BRAIN BLOOD FLOW; BRAIN PERFUSION; BRAIN SCINTISCANNING; DIAGNOSTIC ACCURACY; EDITORIAL; HUMAN; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGE QUALITY; INTERMETHOD COMPARISON; NUCLEAR MAGNETIC RESONANCE IMAGING; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY;

EID: 0031855704     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.208.2.9680551     Document Type: Editorial
Times cited : (20)

References (35)
  • 1
    • 0023847908 scopus 로고
    • Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effects
    • Villringer A, Rosen BR, Belliveau JW, et al. Dynamic imaging with lanthanide chelates in normal brain: contrast due to magnetic susceptibility effects. Magn Reson Med 1988; 6:164-174.
    • (1988) Magn Reson Med , vol.6 , pp. 164-174
    • Villringer, A.1    Rosen, B.R.2    Belliveau, J.W.3
  • 2
    • 0021979203 scopus 로고
    • Tissue distribution and magnetic resonance spin lattice relaxation effects of gadolinium-DTPA
    • Strich G, Hagan PL, Gerber KH, Slutsky RA. Tissue distribution and magnetic resonance spin lattice relaxation effects of gadolinium-DTPA. Radiology 1985; 154: 723-726.
    • (1985) Radiology , vol.154 , pp. 723-726
    • Strich, G.1    Hagan, P.L.2    Gerber, K.H.3    Slutsky, R.A.4
  • 3
    • 0026081190 scopus 로고
    • MR contrast due to microscopically heterogeneous magnetic susceptibility: Numerical simulations and applications to cerebral physiology
    • Fisel CR, Ackerman JL, Buxton RB, et al. MR contrast due to microscopically heterogeneous magnetic susceptibility: numerical simulations and applications to cerebral physiology. Magn Reson Med 1991; 17:336-347.
    • (1991) Magn Reson Med , vol.17 , pp. 336-347
    • Fisel, C.R.1    Ackerman, J.L.2    Buxton, R.B.3
  • 4
    • 0026343822 scopus 로고
    • Susceptibility contrast imaging of cerebral blood volume: Human experience
    • Rosen BR, Belliveau JW, Aronen HJ, et al. Susceptibility contrast imaging of cerebral blood volume: human experience. Magn Reson Med 1991; 22:293-299.
    • (1991) Magn Reson Med , vol.22 , pp. 293-299
    • Rosen, B.R.1    Belliveau, J.W.2    Aronen, H.J.3
  • 5
    • 0020659564 scopus 로고
    • Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique
    • Axel L. Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique. Invest Radiol 1983; 18:94-99.
    • (1983) Invest Radiol , vol.18 , pp. 94-99
    • Axel, L.1
  • 6
    • 0027481892 scopus 로고
    • Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
    • Weisskoff RM, Chesler D, Boxerman JL, Rosen BR. Pitfalls in MR measurement of tissue blood flow with intravascular tracers: which mean transit time? Magn Reson Med 1993; 29:553-558.
    • (1993) Magn Reson Med , vol.29 , pp. 553-558
    • Weisskoff, R.M.1    Chesler, D.2    Boxerman, J.L.3    Rosen, B.R.4
  • 7
  • 8
    • 0028072844 scopus 로고
    • Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging
    • Remp KA, Brix G, Wenz F, Becker CR, Gückel F, Lorenz WJ. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology 1994; 193: 637-641.
    • (1994) Radiology , vol.193 , pp. 637-641
    • Remp, K.A.1    Brix, G.2    Wenz, F.3    Becker, C.R.4    Gückel, F.5    Lorenz, W.J.6
  • 9
    • 0000606319 scopus 로고
    • Theoretical basis of indicator-dilution methods for measuring flow and volume
    • Zierler KL. Theoretical basis of indicator-dilution methods for measuring flow and volume. Circ Res 1965; 16:393-407.
    • (1965) Circ Res , vol.16 , pp. 393-407
    • Zierler, K.L.1
  • 10
    • 0029909977 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. II. Experimental comparison and preliminary results
    • Ostergaard L, Sorensen AG, Kwong KK, Weisskoff RM, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. II. Experimental comparison and preliminary results. Magn Reson Med 1996; 36:726-736.
    • (1996) Magn Reson Med , vol.36 , pp. 726-736
    • Ostergaard, L.1    Sorensen, A.G.2    Kwong, K.K.3    Weisskoff, R.M.4    Gyldensted, C.5    Rosen, B.R.6
  • 11
    • 0022969218 scopus 로고
    • MR imaging of intravoxel incoherent motions: Application to diffusion and perfusion in neurologic disorders
    • LeBihan D, Breton E, Lallemand D, Grenier P, Cabanis EA, Laval-Jeantet M. MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 1986; 161:401-407.
    • (1986) Radiology , vol.161 , pp. 401-407
    • LeBihan, D.1    Breton, E.2    Lallemand, D.3    Grenier, P.4    Cabanis, E.A.5    Laval-Jeantet, M.6
  • 13
  • 14
    • 0030962529 scopus 로고    scopus 로고
    • Effect of magnetization transfer on the measurement of cerebral blood flow using steady-state arterial spin tagging approaches: A theoretical investigation
    • McLaughlin AC, Ye FQ, Pekar JJ, Santha AKS, Frank JA. Effect of magnetization transfer on the measurement of cerebral blood flow using steady-state arterial spin tagging approaches: a theoretical investigation. Magn Reson Med 1997; 37:501-510.
    • (1997) Magn Reson Med , vol.37 , pp. 501-510
    • McLaughlin, A.C.1    Ye, F.Q.2    Pekar, J.J.3    Santha, A.K.S.4    Frank, J.A.5
  • 16
    • 0029952944 scopus 로고    scopus 로고
    • Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    • Alsop DC, Detre JA. Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow. J Cereb Blood Flow Metab 1996; 16:1236-1249.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 1236-1249
    • Alsop, D.C.1    Detre, J.A.2
  • 17
    • 0031022848 scopus 로고    scopus 로고
    • Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques
    • Ye FQ, Mattay VS, Jezzard P, Frank JA, Weinberger DR, McLaughlin AC. Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques. Magn Reson Med 1997; 37:226-235.
    • (1997) Magn Reson Med , vol.37 , pp. 226-235
    • Ye, F.Q.1    Mattay, V.S.2    Jezzard, P.3    Frank, J.A.4    Weinberger, D.R.5    McLaughlin, A.C.6
  • 18
    • 0030723478 scopus 로고    scopus 로고
    • The efficiency of adiabatic inversion for perfusion imaging by arterial spin labeling
    • Maccotta L, Detre JA, Alsop DC. The efficiency of adiabatic inversion for perfusion imaging by arterial spin labeling. NMR Biomed 1997; 10:216-221.
    • (1997) NMR Biomed , vol.10 , pp. 216-221
    • Maccotta, L.1    Detre, J.A.2    Alsop, D.C.3
  • 19
    • 0026653875 scopus 로고
    • Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation
    • Kwong KK, Belliveau JW, Chesler DA, et al. Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. Proc Natl Acad Sci USA 1992; 89:5675-5679.
    • (1992) Proc Natl Acad Sci USA , vol.89 , pp. 5675-5679
    • Kwong, K.K.1    Belliveau, J.W.2    Chesler, D.A.3
  • 20
    • 0029151256 scopus 로고
    • Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
    • Kim SG. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med 1995; 34:293-301.
    • (1995) Magn Reson Med , vol.34 , pp. 293-301
    • Kim, S.G.1
  • 21
    • 0027936294 scopus 로고
    • Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency
    • Edelman RR, Siewert B, Darby DG, et al. Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency. Radiology 1994; 192:513-520.
    • (1994) Radiology , vol.192 , pp. 513-520
    • Edelman, R.R.1    Siewert, B.2    Darby, D.G.3
  • 22
    • 0030725989 scopus 로고    scopus 로고
    • Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling
    • Wong EC, Buxton RB, Frank LR. Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling. NMR Biomed 1997; 10:237-249.
    • (1997) NMR Biomed , vol.10 , pp. 237-249
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 23
    • 0031876165 scopus 로고    scopus 로고
    • Multisection cerebral blood flow MR imaging with continuous arterial spin labeling
    • Alsop DC, Detre JA. Multisection cerebral blood flow MR imaging with continuous arterial spin labeling. Radiology 1998; 208: 410-416.
    • (1998) Radiology , vol.208 , pp. 410-416
    • Alsop, D.C.1    Detre, J.A.2
  • 24
    • 0025269066 scopus 로고
    • First-pass cardiac perfusion: Evaluation with ultrafast MR imaging
    • Atkinson DJ, Burstein D, Edelman RR. First-pass cardiac perfusion: evaluation with ultrafast MR imaging. Radiology 1990; 174:757-762.
    • (1990) Radiology , vol.174 , pp. 757-762
    • Atkinson, D.J.1    Burstein, D.2    Edelman, R.R.3
  • 25
    • 0027283766 scopus 로고
    • Magnetic resonance imaging of perfusion in the isolated rat heart using steady-state spin inversion of arterial water
    • Williams DS, Grandis DJ, Zhang W, Koretsky AP. Magnetic resonance imaging of perfusion in the isolated rat heart using steady-state spin inversion of arterial water. Magn Reson Med 1993; 30:361-365.
    • (1993) Magn Reson Med , vol.30 , pp. 361-365
    • Williams, D.S.1    Grandis, D.J.2    Zhang, W.3    Koretsky, A.P.4
  • 26
    • 0029950010 scopus 로고    scopus 로고
    • Quantitative cardiac perfusion: A noninvasive spin-labeling method that exploits coronary vessel geometry
    • Reeder SB, Atalay MK, McVeigh ER, Zerhouni EA, Forder JR. Quantitative cardiac perfusion: a noninvasive spin-labeling method that exploits coronary vessel geometry. Radiology 1996; 200:177-184.
    • (1996) Radiology , vol.200 , pp. 177-184
    • Reeder, S.B.1    Atalay, M.K.2    McVeigh, E.R.3    Zerhouni, E.A.4    Forder, J.R.5
  • 27
    • 0029060933 scopus 로고
    • Renal perfusion in humans: MR imaging with spin tagging of arterial water
    • Roberts DA, Detre JA, Bolinger L, et al. Renal perfusion in humans: MR imaging with spin tagging of arterial water. Radiology 1995; 196:281-286.
    • (1995) Radiology , vol.196 , pp. 281-286
    • Roberts, D.A.1    Detre, J.A.2    Bolinger, L.3
  • 28
    • 0030049425 scopus 로고    scopus 로고
    • Clinical outcome in ischemic stroke predicted by early diffusion-weighted and perfusion magnetic resonance imaging: A preliminary analysis
    • Warach S, Dashe JF, Edelman RR. Clinical outcome in ischemic stroke predicted by early diffusion-weighted and perfusion magnetic resonance imaging: a preliminary analysis. J Cereb Blood Flow Metab 1996; 16:53-59.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 53-59
    • Warach, S.1    Dashe, J.F.2    Edelman, R.R.3
  • 29
    • 0005063990 scopus 로고    scopus 로고
    • Quantitative multi-slice perfusion imaging of patients diagnosed with Alzheimer's of frontal dementia
    • Berkeley, Calif: International Society for Magnetic Resonance in Medicine
    • Alsop DC, Grossman M, Detre JA. Quantitative multi-slice perfusion imaging of patients diagnosed with Alzheimer's of frontal dementia (abstr). In: Proceedings of the Sixth Meeting of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 1998; 3:1587.
    • (1998) Proceedings of the Sixth Meeting of the International Society for Magnetic Resonance in Medicine , vol.3 , pp. 1587
    • Alsop, D.C.1    Grossman, M.2    Detre, J.A.3
  • 30
    • 0032042322 scopus 로고    scopus 로고
    • Magnetic resonance imaging in acute stroke: Not ready for prime time
    • Powers WJ, Zivin J. Magnetic resonance imaging in acute stroke: not ready for prime time. Neurology 1998; 50:842-843.
    • (1998) Neurology , vol.50 , pp. 842-843
    • Powers, W.J.1    Zivin, J.2
  • 31
    • 0020573697 scopus 로고
    • Functional recovery of cortical neurons as related to degree and duration of ischemia
    • Heiss WD, Rosner G. Functional recovery of cortical neurons as related to degree and duration of ischemia. Ann Neurol 1983; 14:294-301.
    • (1983) Ann Neurol , vol.14 , pp. 294-301
    • Heiss, W.D.1    Rosner, G.2
  • 32
    • 85038536467 scopus 로고    scopus 로고
    • The critical residual flow level for successful thrombolytic therapy
    • Heiss WD, Grond M, Thiel A, et al. The critical residual flow level for successful thrombolytic therapy (abstr). J Cereb Blood Flow Metab 1997; 17(suppl):S109.
    • (1997) J Cereb Blood Flow Metab , vol.17 , Issue.SUPPL.
    • Heiss, W.D.1    Grond, M.2    Thiel, A.3
  • 33
    • 0346607192 scopus 로고    scopus 로고
    • Evaluation of focal perfusion defects due to symptomatic middle cerebral artery stenosis using arterial spin labeling perfusion magnetic resonance imaging
    • Samuels OB, Detre JA, Alsop DC, Kasner SE, Teener JW, Raps EC. Evaluation of focal perfusion defects due to symptomatic middle cerebral artery stenosis using arterial spin labeling perfusion magnetic resonance imaging (abstr). Neurology 1998; 50(suppl):A77.
    • (1998) Neurology , vol.50 , Issue.SUPPL.
    • Samuels, O.B.1    Detre, J.A.2    Alsop, D.C.3    Kasner, S.E.4    Teener, J.W.5    Raps, E.C.6
  • 35
    • 0031883407 scopus 로고    scopus 로고
    • Quantitative assessment of blood flow, blood volume and blood oxygenation effects in functional magnetic resonance imaging
    • van Zijl PC, Eleff SM, Ulatowski JA, et al. Quantitative assessment of blood flow, blood volume and blood oxygenation effects in functional magnetic resonance imaging. Nature Med 1998; 4:159-167.
    • (1998) Nature Med , vol.4 , pp. 159-167
    • Van Zijl, P.C.1    Eleff, S.M.2    Ulatowski, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.