메뉴 건너뛰기




Volumn 9, Issue 3, 1998, Pages 11-15

Surgical management of posteriorly dislocated silicone plate intraocular lenses

Author keywords

[No Author keywords available]

Indexed keywords

POLY(METHYL METHACRYLATE); SILICONE;

EID: 0031850667     PISSN: 10408738     EISSN: None     Source Type: Journal    
DOI: 10.1097/00055735-199806000-00003     Document Type: Short Survey
Times cited : (14)

References (22)
  • 1
    • 0019313693 scopus 로고
    • Management of posteriorly dislocated intraocular lenses
    • Stark WJ, Michels RG, Bruner WE: Management of posteriorly dislocated intraocular lenses. Ophthalmic Surg 1980, 11:495-497.
    • (1980) Ophthalmic Surg , vol.11 , pp. 495-497
    • Stark, W.J.1    Michels, R.G.2    Bruner, W.E.3
  • 2
    • 0024464626 scopus 로고
    • Pars plana vitrectomy in the management of dislocated posterior chamber lenses
    • Campo RV, Chung KD, Oyakawa RT: Pars plana vitrectomy in the management of dislocated posterior chamber lenses. Am J Ophthalmol 1989, 108:529-534.
    • (1989) Am J Ophthalmol , vol.108 , pp. 529-534
    • Campo, R.V.1    Chung, K.D.2    Oyakawa, R.T.3
  • 3
    • 0025872975 scopus 로고
    • Management of dislocated posterior chamber intraocular lenses
    • Smiddy WE, Flynn Jr HW: Management of dislocated posterior chamber intraocular lenses. Ophthalmology 1991, 98:889-894.
    • (1991) Ophthalmology , vol.98 , pp. 889-894
    • Smiddy, W.E.1    Flynn Jr., H.W.2
  • 4
    • 0027195655 scopus 로고
    • The use of perfluorocarbon liquids in the repositioning of posteriorly dislocated intraocular lenses
    • Lewis H, Sanchez G: The use of perfluorocarbon liquids in the repositioning of posteriorly dislocated intraocular lenses. Ophthalmology 1993, 100:1055-1059.
    • (1993) Ophthalmology , vol.100 , pp. 1055-1059
    • Lewis, H.1    Sanchez, G.2
  • 5
    • 0029591356 scopus 로고
    • Clinical management of posterior chamber intraocular lens implants dislocated in the vitreous cavity
    • Shakin EP, Carty JB Jr: Clinical management of posterior chamber intraocular lens implants dislocated in the vitreous cavity. Ophthalmic Surg Lasers 1995, 26:529-534.
    • (1995) Ophthalmic Surg Lasers , vol.26 , pp. 529-534
    • Shakin, E.P.1    Carty Jr., J.B.2
  • 6
    • 0027219294 scopus 로고
    • Postoperative complications and uncorrected acuities after implantation of plate haptic silicone and three-piece silicone intraocular lenses
    • Cumming JS: Postoperative complications and uncorrected acuities after implantation of plate haptic silicone and three-piece silicone intraocular lenses. J Cataract Refract Surg 1993, 19:263-274.
    • (1993) J Cataract Refract Surg , vol.19 , pp. 263-274
    • Cumming, J.S.1
  • 8
    • 0030159959 scopus 로고    scopus 로고
    • Posterior dislocation of plate haptic silicone lenses
    • Gonzalez GA, Irvine AR: Posterior dislocation of plate haptic silicone lenses. Arch Ophthalmol 1996, 114:775-776. A report of three cases of posterior dislocation of plate haptic silicone lenses following secondary or primary capsular breaks. Illustrates that compromise of any portion of the capsular bag can lead to dislocation, and discusses the mechanism of dislocation.
    • (1996) Arch Ophthalmol , vol.114 , pp. 775-776
    • Gonzalez, G.A.1    Irvine, A.R.2
  • 9
    • 0030924685 scopus 로고    scopus 로고
    • Surgical management of posteriorly dislocated silicone plate haptic intraocular lenses
    • Schneiderman TE, Johnson MW, Smiddy WE. Flynn HW Jr, Bennett SR, Cantrill HL: Surgical management of posteriorly dislocated silicone plate haptic intraocular lenses. Am J Ophthalmol 1997, 123:629-635. A recent series of 11 cases of delayed posterior dislocation of silicone plate intraocular lenses occuring after secondary Nd:YAG laser capsulotomy or primary capsular or zonular dehiscence. Describes microsurgical techniques for retrieving and manipulating silicone lenses in the vitreous cavity and emphasizes that non-sutured repositioning in the ciliary sulcus is a safe management option in eyes with adequate anterior capsular support.
    • (1997) Am J Ophthalmol , vol.123 , pp. 629-635
    • Schneiderman, T.E.1    Johnson, M.W.2    Smiddy, W.E.3    Flynn Jr., H.W.4    Bennett, S.R.5    Cantrill, H.L.6
  • 11
    • 0024427670 scopus 로고
    • Physical fixation of soft intraocular lenses
    • Shimizu K, Komatsu M: Physical fixation of soft intraocular lenses. J Cataract Refract Surg 1989, 15:580-583.
    • (1989) J Cataract Refract Surg , vol.15 , pp. 580-583
    • Shimizu, K.1    Komatsu, M.2
  • 12
    • 0026567334 scopus 로고
    • A comparison of 141 polymacon (logel) and 140 poly(methyl methacrylate) intraocular lens implants
    • Lowe KJ, Easty DL: A comparison of 141 polymacon (logel) and 140 poly(methyl methacrylate) intraocular lens implants. Br J Ophthalmol 1992, 76:88-90.
    • (1992) Br J Ophthalmol , vol.76 , pp. 88-90
    • Lowe, K.J.1    Easty, D.L.2
  • 13
    • 0024396242 scopus 로고
    • Continuous-tear capsulotomy and insertion of a silicone bag lens
    • Shepherd JR: Continuous-tear capsulotomy and insertion of a silicone bag lens. J Cataract Refract Surg 1989, 15:335-339.
    • (1989) J Cataract Refract Surg , vol.15 , pp. 335-339
    • Shepherd, J.R.1
  • 14
    • 0027301363 scopus 로고
    • Capsule contraction syndrome
    • Davison JA: Capsule contraction syndrome. J Cataract Refract Surg 1993, 19:582-589.
    • (1993) J Cataract Refract Surg , vol.19 , pp. 582-589
    • Davison, J.A.1
  • 15
    • 0029891628 scopus 로고    scopus 로고
    • Capsular opening contraction after continuous curvilinear capsulorhexis and intraocular lens implantation
    • Joo CK, Shin JA, Kim JH: Capsular opening contraction after continuous curvilinear capsulorhexis and intraocular lens implantation. J Cataract Refract Surg 1996, 22:585-590.
    • (1996) J Cataract Refract Surg , vol.22 , pp. 585-590
    • Joo, C.K.1    Shin, J.A.2    Kim, J.H.3
  • 16
    • 0022461446 scopus 로고
    • Early experience with STAAR silicone elastic lens implants
    • Faulkner GD: Early experience with STAAR silicone elastic lens implants. J Cataract Refract Surg 1986, 12:36-39.
    • (1986) J Cataract Refract Surg , vol.12 , pp. 36-39
    • Faulkner, G.D.1
  • 17
    • 0027261267 scopus 로고
    • Surgical complications and visual acuity results in 536 cases of plate haptic silicone lens implantation
    • Cumming JS: Surgical complications and visual acuity results in 536 cases of plate haptic silicone lens implantation. J Cataract Refract Surg 1993, 19:275-277.
    • (1993) J Cataract Refract Surg , vol.19 , pp. 275-277
    • Cumming, J.S.1
  • 18
    • 0024990356 scopus 로고
    • Capsular bag fixation of one-piece silicone lenses
    • Milauskas AT: Capsular bag fixation of one-piece silicone lenses. J Cataract Refract Surg 1990, 16:583-586.
    • (1990) J Cataract Refract Surg , vol.16 , pp. 583-586
    • Milauskas, A.T.1
  • 20
    • 0025085585 scopus 로고
    • Displacement of bag-placed hydrogel lenses into the vitreous following neodymium:YAG laser capsulotomy
    • Levy JH, Pisacano AM, Anello RD: Displacement of bag-placed hydrogel lenses into the vitreous following neodymium:YAG laser capsulotomy. J Cataract Refract Surg 1990, 16:563-566.
    • (1990) J Cataract Refract Surg , vol.16 , pp. 563-566
    • Levy, J.H.1    Pisacano, A.M.2    Anello, R.D.3
  • 21
    • 0025178978 scopus 로고
    • Secondary evaluation of hydrogel lens implants
    • Noble BA, Hayward JM, Huber C: Secondary evaluation of hydrogel lens implants. Eye 1990, 4:450-455.
    • (1990) Eye , vol.4 , pp. 450-455
    • Noble, B.A.1    Hayward, J.M.2    Huber, C.3
  • 22
    • 0030480401 scopus 로고    scopus 로고
    • Clinical results of implanting a silicone haptic-anchor-plate intraocular lens
    • Colin J: Clinical results of implanting a silicone haptic-anchor-plate intraocular lens. J Cataract Refract Surg 1996, 22:1286-1290.
    • (1996) J Cataract Refract Surg , vol.22 , pp. 1286-1290
    • Colin, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.