메뉴 건너뛰기




Volumn 80, Issue 7, 1998, Pages 980-984

Revision of a total hip arthroplasty with a Harris-Galante porous- coated acetabular component inserted without cement: A follow-up note on the results at five to twelve years

Author keywords

[No Author keywords available]

Indexed keywords

ALLOGRAFT; ARTICLE; BONE GRAFT; DISEASE CLASSIFICATION; FOLLOW UP; HIP FRACTURE; HIP RADIOGRAPHY; HUMAN; MAJOR CLINICAL STUDY; OSTEOTOMY; PRIORITY JOURNAL; SURGICAL TECHNIQUE; TOTAL HIP PROSTHESIS; TREATMENT OUTCOME;

EID: 0031845209     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/00004623-199807000-00006     Document Type: Article
Times cited : (71)

References (18)
  • 2
    • 0015754154 scopus 로고
    • Ectopic ossification following total hip replacement. Incidence and a method of classification
    • Dec.
    • Brooker, A. F.; Bowerman, J. W.; Robinson, R. A.; and Riley, L. H., Jr.: Ectopic ossification following total hip replacement. Incidence and a method of classification. J. Bone and Joint Surg., 55-A: 1629-1632, Dec. 1973.
    • (1973) J. Bone and Joint Surg. , vol.55 A , pp. 1629-1632
    • Brooker, A.F.1    Bowerman, J.W.2    Robinson, R.A.3    Riley Jr., L.H.4
  • 3
    • 0021817452 scopus 로고
    • Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up
    • Sept.
    • Callaghan, J. J.; Salvati, E. A.; Pellicci, P. M.; Wilson, P. D., Jr.; and Ranawat, C. S.: Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up. J. Bone and Joint Surg., 67-A: 1074-1085, Sept. 1985.
    • (1985) J. Bone and Joint Surg. , vol.67 A , pp. 1074-1085
    • Callaghan, J.J.1    Salvati, E.A.2    Pellicci, P.M.3    Wilson Jr., P.D.4    Ranawat, C.S.5
  • 5
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • DeLee, J. G., and Charnley, J,: Radiological demarcation of cemented sockets in total hip replacement. Clin. Orthop., 121: 20-32, 1976.
    • (1976) Clin. Orthop. , vol.121 , pp. 20-32
    • DeLee, J.G.1    Charnley, J.2
  • 6
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty. An end-result study using a new method of result evaluation
    • June
    • Harris, W. H.: Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J. Bone and Joint Surg., 51-A: 737-755, June 1969.
    • (1969) J. Bone and Joint Surg. , vol.51 A , pp. 737-755
    • Harris, W.H.1
  • 7
    • 0028845169 scopus 로고
    • Morselized allograft in acetabular reconstruction. A postmortem retrieval analysis
    • Heekin, R. D.; Engh, C. A.; and Vinh, T.: Morselized allograft in acetabular reconstruction. A postmortem retrieval analysis. Clin. Orthop., 319: 184-190, 1995.
    • (1995) Clin. Orthop. , vol.319 , pp. 184-190
    • Heekin, R.D.1    Engh, C.A.2    Vinh, T.3
  • 9
    • 0027272895 scopus 로고
    • High failure rate of bulk femoral head allografts in total hip acetabular reconstructions at 10 years
    • Kwong, L. M.; Jasty, M.; and Harris, W. H.: High failure rate of bulk femoral head allografts in total hip acetabular reconstructions at 10 years. J. Arthroplasty, 8: 341-346, 1993.
    • (1993) J. Arthroplasty , vol.8 , pp. 341-346
    • Kwong, L.M.1    Jasty, M.2    Harris, W.H.3
  • 10
    • 0028656489 scopus 로고
    • Revision of the acetabulum without cement with use of the Harris-Galante porous-coated implant. Two to eight-year results
    • Dec.
    • Lachiewicz, P. F., and Hussamy, O. D.: Revision of the acetabulum without cement with use of the Harris-Galante porous-coated implant. Two to eight-year results. J. Bone and Joint Surg., 76-A: 1834-1839, Dec. 1994.
    • (1994) J. Bone and Joint Surg. , vol.76 A , pp. 1834-1839
    • Lachiewicz, P.F.1    Hussamy, O.D.2
  • 11
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • April
    • Livermore, J.; Ilstrup, D.; and Morrey, B.: Effect of femoral head size on wear of the polyethylene acetabular component. J. Bone and Joint Surg., 72-A: 518-528, April 1990.
    • (1990) J. Bone and Joint Surg. , vol.72 A , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 12
    • 0025161599 scopus 로고
    • The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review
    • Mulroy, R. D., Jr., and Harris, W. H.: The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review. J. Bone and Joint Surg., 72-B(5): 757-760, 1990.
    • (1990) J. Bone and Joint Surg. , vol.72 B , Issue.5 , pp. 757-760
    • Mulroy Jr., R.D.1    Harris, W.H.2
  • 13
    • 0029018279 scopus 로고
    • Acetabular revision with the Burch-Schneider antiprotrusio cage and cancellous allograft bone
    • Peters, C. L.; Curtain, M.; and Samuelson, K. M.: Acetabular revision with the Burch-Schneider antiprotrusio cage and cancellous allograft bone. J. Arthroplasly, 10: 307-312, 1995.
    • (1995) J. Arthroplasly , vol.10 , pp. 307-312
    • Peters, C.L.1    Curtain, M.2    Samuelson, K.M.3
  • 14
    • 0029007450 scopus 로고
    • Cemented revision for aseptic acetabular loosening. A review of 387 hips
    • Raut, V. V.; Siney, P. D.; and Wroblewski, B. ML: Cemented revision for aseptic acetabular loosening. A review of 387 hips. J. Bone and Joint Surg., 77-B(3): 357-361, 1995.
    • (1995) J. Bone and Joint Surg. , vol.77 B , Issue.3 , pp. 357-361
    • Raut, V.V.1    Siney, P.D.2    Wroblewski, B.M.L.3
  • 15
    • 0029793627 scopus 로고    scopus 로고
    • Revision of the acetabular component without cement after total hip arthroplasty. A follow-up note regarding results at seven to eleven years
    • Sept.
    • Silverton, C. D.; Rosenberg, A. G.; Sheinkop, M. B.; Kull, L. R.; and Galante, J. O.: Revision of the acetabular component without cement after total hip arthroplasty. A follow-up note regarding results at seven to eleven years. J. Bone and Joint Surg., 78-A: 1366-1370, Sept. 1996.
    • (1996) J. Bone and Joint Surg. , vol.78 A , pp. 1366-1370
    • Silverton, C.D.1    Rosenberg, A.G.2    Sheinkop, M.B.3    Kull, L.R.4    Galante, J.O.5
  • 17
    • 0026803457 scopus 로고
    • Revision of the acetabular component with an uncemented Harris-Galante porous-coated prosthesis
    • Aug.
    • Tanzer, M.; Drucker, D.; Jasty, M.; McDonald, M.; and Harris, W. H.: Revision of the acetabular component with an uncemented Harris-Galante porous-coated prosthesis. J. Bone and Joint Surg., 74-A: 987-994, Aug. 1992.
    • (1992) J. Bone and Joint Surg. , vol.74 A , pp. 987-994
    • Tanzer, M.1    Drucker, D.2    Jasty, M.3    McDonald, M.4    Harris, W.H.5
  • 18
    • 0028144008 scopus 로고
    • Midterm results (5.5-10 years) of acetabular allograft reconstruction with the acetabular reinforcement ring during total hip revision
    • Zehntner, M. K., and Ganz, R.: Midterm results (5.5-10 years) of acetabular allograft reconstruction with the acetabular reinforcement ring during total hip revision. J. Arthroplasty, 9: 469-479, 1994.
    • (1994) J. Arthroplasty , vol.9 , pp. 469-479
    • Zehntner, M.K.1    Ganz, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.