메뉴 건너뛰기




Volumn 60, Issue 3, 1998, Pages 165-168

Renal needle biopsy along the retrograde puncture line of the renal calyx: A new promising technique

Author keywords

Biopty gun; Kidney; Needle biopsy; Retrograde nephrostomy

Indexed keywords

ADULT; ARTICLE; BLEEDING; CASE REPORT; CATHETER; CLINICAL TRIAL; FEMALE; HUMAN; HUMAN TISSUE; KIDNEY BIOPSY; KIDNEY CALYX; KIDNEY PELVIS; MALE; NEEDLE; NEEDLE BIOPSY; NEPHROSTOMY; PRIORITY JOURNAL;

EID: 0031843701     PISSN: 00421138     EISSN: None     Source Type: Journal    
DOI: 10.1159/000030243     Document Type: Article
Times cited : (2)

References (8)
  • 1
    • 0027507589 scopus 로고
    • The use of the automated core biopsy system in percutaneous renal biopsies: A comparative study
    • Burstein DM, Korbet SM, Schwartz MM: The use of the automated core biopsy system in percutaneous renal biopsies: A comparative study. Am J Kidney Dis 1993;22:545.
    • (1993) Am J Kidney Dis , vol.22 , pp. 545
    • Burstein, D.M.1    Korbet, S.M.2    Schwartz, M.M.3
  • 2
    • 0027142047 scopus 로고
    • Blinded comparison of biopsy needles and automated devices in vitro. 2: Biopsy of medical renal disease
    • Hopper KD, Abendroth CS, Sturtz KW, et al: Blinded comparison of biopsy needles and automated devices in vitro. 2: Biopsy of medical renal disease. Am J Roentogenol 1993;161:1299.
    • (1993) Am J Roentogenol , vol.161 , pp. 1299
    • Hopper, K.D.1    Abendroth, C.S.2    Sturtz, K.W.3
  • 3
    • 0029651753 scopus 로고
    • Percutaneous renal biopsy: An audit of a 2 year experience with the Biopty-gun
    • Voss DM, Lynn KL: Percutaneous renal biopsy: An audit of a 2 year experience with the Biopty-gun. NZ Med J 1995;108:8.
    • (1995) NZ Med J , vol.108 , pp. 8
    • Voss, D.M.1    Lynn, K.L.2
  • 4
    • 0026699642 scopus 로고
    • Renal biopsy in diffuse renal disease: Experience with a 14-gauge automated biopsy-gun
    • Tung KT, Downes MO, O'Donnell J: Renal biopsy in diffuse renal disease: Experience with a 14-gauge automated biopsy-gun. Clin Radiol 1992;46:111.
    • (1992) Clin Radiol , vol.46 , pp. 111
    • Tung, K.T.1    Downes, M.O.2    O'Donnell, J.3
  • 6
    • 0023634980 scopus 로고
    • Renal biopsy-related hemorrhage: Frequency and comparison of CT and sonography
    • Ralls PW, Barakos JA, Kaptein EM, et al. Renal biopsy-related hemorrhage: Frequency and comparison of CT and sonography. J Comput Assist Tomogr 1987;11:1031.
    • (1987) J Comput Assist Tomogr , vol.11 , pp. 1031
    • Ralls, P.W.1    Barakos, J.A.2    Kaptein, E.M.3
  • 7
    • 7144262469 scopus 로고
    • A biopsy technique using biopty-gun under ultrasound guidance
    • Ohmori H, Arimoto K, Taki M, Kumon H: A biopsy technique using biopty-gun under ultrasound guidance. Kidney Dial 1991;31:379-382.
    • (1991) Kidney Dial , vol.31 , pp. 379-382
    • Ohmori, H.1    Arimoto, K.2    Taki, M.3    Kumon, H.4
  • 8
    • 0001410247 scopus 로고
    • Evaluation of kidney biopsy specimens
    • Tisher CG, Brenner BM (eds): Philadelphia, Lippincott
    • Pirani CL: Evaluation of kidney biopsy specimens; in Tisher CG, Brenner BM (eds): Renal pathology with Clinical and Functional Correlations. Philadelphia, Lippincott, 1989;pp 11-42.
    • (1989) Renal Pathology with Clinical and Functional Correlations , pp. 11-42
    • Pirani, C.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.