메뉴 건너뛰기




Volumn 13, Issue 4, 1998, Pages 422-427

Bone loss around 2 different types of hip prostheses

Author keywords

Bateman prosthesis; Bone mineral density; Gruen zone; Periprosthetic; Porous coated anatomic; Stem

Indexed keywords

ADULT; AGED; ARTICLE; BONE ATROPHY; BONE DENSITY; BONE MINERAL; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; FOLLOW UP; HIP PROSTHESIS; HUMAN; HUMAN CELL; HUMAN TISSUE; MALE; REPRODUCIBILITY;

EID: 0031840549     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(98)90008-0     Document Type: Article
Times cited : (34)

References (14)
  • 2
    • 0023777583 scopus 로고
    • The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty
    • Engh CA, Bobyn JD: The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop 231:7, 1988
    • (1988) Clin Orthop , vol.231 , pp. 7
    • Engh, C.A.1    Bobyn, J.D.2
  • 4
    • 0026718908 scopus 로고
    • The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement
    • Tanzer M, Maloney WJ, Jasty M, Harris WH: The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement. J Bone Joint Surg [Br] 74-A:404, 1992
    • (1992) J Bone Joint Surg [Br] , vol.74 A , pp. 404
    • Tanzer, M.1    Maloney, W.J.2    Jasty, M.3    Harris, W.H.4
  • 5
    • 0026622955 scopus 로고
    • Proximal femoral bone loss after total hip arthroplasty
    • Roberson JR: Proximal femoral bone loss after total hip arthroplasty. Orthop Clin N Am 23:291, 1992
    • (1992) Orthop Clin N Am , vol.23 , pp. 291
    • Roberson, J.R.1
  • 6
    • 0026464523 scopus 로고
    • Determination of bone mineral density by dual x-ray absorptiometry in patients with uncemented total hip arthroplasty
    • Kiratli BJ, Heiner JP, Mcbeath AA, Wilson MA: Determination of bone mineral density by dual x-ray absorptiometry in patients with uncemented total hip arthroplasty. J Orthop Res 10:836, 1992
    • (1992) J Orthop Res , vol.10 , pp. 836
    • Kiratli, B.J.1    Heiner, J.P.2    Mcbeath, A.A.3    Wilson, M.A.4
  • 7
    • 0027409719 scopus 로고
    • Dual-energy x-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants: Methods and preliminary results
    • Kilgus DJ, Shimaoka EE, Tipton JS, Eberle RW: Dual-energy x-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants: methods and preliminary results. J Bone Joint Surg [Br] 75:279, 1993
    • (1993) J Bone Joint Surg [Br] , vol.75 , pp. 279
    • Kilgus, D.J.1    Shimaoka, E.E.2    Tipton, J.S.3    Eberle, R.W.4
  • 12
    • 0028944925 scopus 로고
    • Atrophy of the proximal part of the femur after total hip arthroplasty without cement: A quantitative comparison of cobalt-chromium and titanium femoral stems with use of dual x-ray absorptiometry
    • Hughes SS, Furia JP, Smith P, Pellegrini VD Jr: Atrophy of the proximal part of the femur after total hip arthroplasty without cement: a quantitative comparison of cobalt-chromium and titanium femoral stems with use of dual x-ray absorptiometry. J Bone Joint Surg [Am] 77:2, 231, 1995
    • (1995) J Bone Joint Surg [Am] , vol.77 , Issue.2 , pp. 231
    • Hughes, S.S.1    Furia, J.P.2    Smith, P.3    Pellegrini Jr., V.D.4
  • 13
    • 0021992636 scopus 로고
    • Osteolytic changes in the upper femoral shaft following porous coated cementless femoral implants
    • Brown IW, Ring PA: Osteolytic changes in the upper femoral shaft following porous coated cementless femoral implants. J Bone Joint Surg [Br] 67:218, 1985
    • (1985) J Bone Joint Surg [Br] , vol.67 , pp. 218
    • Brown, I.W.1    Ring, P.A.2
  • 14
    • 0029758076 scopus 로고    scopus 로고
    • Evaluation of periprosthetic bone using dual-energy x-ray absorptiometry: Precision of the method and effect of operation on bone mineral density
    • Kroger H, Miettinen H, Arnala I, Koski E, Rushton N, Suomalainen O: Evaluation of periprosthetic bone using dual-energy x-ray absorptiometry: precision of the method and effect of operation on bone mineral density. J Bone Miner Res 11:10, 1526, 1996
    • (1996) J Bone Miner Res , vol.11 , Issue.10 , pp. 1526
    • Kroger, H.1    Miettinen, H.2    Arnala, I.3    Koski, E.4    Rushton, N.5    Suomalainen, O.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.