Optimal expansion of the Multi-Link stent. An in vitro study using direct magnification radiography;Optimierte expansion des Multi-Link-stents. Eine in-vitro-untersuchung mittels hochauflosender Rontgentechnik

Author keywords

High pressure dilatation; In vitro vessel model; Magnification radiography; Multi Link stent; Stent apposition

Indexed keywords

ARTICLE; CORONARY ARTERY OBSTRUCTION; MAGNIFICATION RADIOGRAPHY; SILICONE PROSTHESIS; STENT;

EID: 0031840470     PISSN: 03005860     EISSN: None     Source Type: Journal    
DOI: 10.1007/s003920050190     Document Type: Article
Times cited : (5)

References (15)
  • 3
    • 0028912131 scopus 로고
    • Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance
    • Colombo A, Hall P, Nakamura S (1995) Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation 91:1676-88
    • (1995) Circulation , vol.91 , pp. 1676-1688
    • Colombo, A.1    Hall, P.2    Nakamura, S.3
  • 4
    • 0029817977 scopus 로고    scopus 로고
    • Hoop dreams. Stents without restenosis
    • Edelmann ER, Rogers C (1996) Hoop dreams. Stents without restenosis. Circulation 6:1199-1202
    • (1996) Circulation , vol.6 , pp. 1199-1202
    • Edelmann, E.R.1    Rogers, C.2
  • 5
    • 0027934377 scopus 로고
    • A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Fishman DL, Leon MB, Baim DS, Schatz RA, Savage MP, Penn I, et al (1994) A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 331:496-501
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fishman, D.L.1    Leon, M.B.2    Baim, D.S.3    Schatz, R.A.4    Savage, M.P.5    Penn, I.6
  • 7
    • 0000038289 scopus 로고    scopus 로고
    • Impact of high inflation pressure on six-month angiographic follow-up after coronary stent placement
    • Hausleiter J, Schühlen H, Elezi S, Walter H, Hadamitzky M (1997) Impact of high inflation pressure on six-month angiographic follow-up after coronary stent placement. J Am Coll Cardiol 97:369 A
    • (1997) J Am Coll Cardiol , vol.97
    • Hausleiter, J.1    Schühlen, H.2    Elezi, S.3    Walter, H.4    Hadamitzky, M.5
  • 9
    • 0027438639 scopus 로고
    • Intravaskulärer Ultraschall bei peripheren verkalkten Gefäßläsionen: Vergleich zur direktradiographischen Vergrößerung
    • Kerber S, Link TM, Fechtrup C, Krings W, Pöppelmann M, et al (1993) Intravaskulärer Ultraschall bei peripheren verkalkten Gefäßläsionen: Vergleich zur direktradiographischen Vergrößerung. Z Kardiol 82: 610-617
    • (1993) Z Kardiol , vol.82 , pp. 610-617
    • Kerber, S.1    Link, T.M.2    Fechtrup, C.3    Krings, W.4    Pöppelmann, M.5
  • 10
    • 0024393107 scopus 로고
    • Restenosis after coronary angioplasty: Potential biologic determinants and role of intimal hyperplasia
    • Liu MW, Roubin GS, King SB III (1989) Restenosis after coronary angioplasty: potential biologic determinants and role of intimal hyperplasia. Circulation 79: 1374-1387
    • (1989) Circulation , vol.79 , pp. 1374-1387
    • Liu, M.W.1    Roubin, G.S.2    King III, S.B.3
  • 13
    • 0028123099 scopus 로고
    • A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease
    • Serruys PW, De Jaegere P, Kiemeneij F, Macaya C, Rutsch W, et al (1994) A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med 331:489-495
    • (1994) N Engl J Med , vol.331 , pp. 489-495
    • Serruys, P.W.1    De Jaegere, P.2    Kiemeneij, F.3    Macaya, C.4    Rutsch, W.5
  • 14
    • 0023153178 scopus 로고
    • Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty
    • Sigwart U, Puel J, Mirkowitch V, Joffre F, Kappenberger L (1987) Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N Engl J Med 316:701-706
    • (1987) N Engl J Med , vol.316 , pp. 701-706
    • Sigwart, U.1    Puel, J.2    Mirkowitch, V.3    Joffre, F.4    Kappenberger, L.5
  • 15
    • 0342292868 scopus 로고    scopus 로고
    • Interaction of balloon size and pressure for optimal stent deployment using intracoronary ultrasound guidance
    • Vardi M, Fishman RF, Ailwadi GA, Parker MA, Meyers SN, et al (1996) Interaction of balloon size and pressure for optimal stent deployment using intracoronary ultrasound guidance. Circulation 94, Suppl I:262
    • (1996) Circulation , vol.94 , Issue.1 SUPPL. , pp. 262
    • Vardi, M.1    Fishman, R.F.2    Ailwadi, G.A.3    Parker, M.A.4    Meyers, S.N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.