-
1
-
-
0013253225
-
Progress in scientific research on acupuncture, moxibustion and acupuncture anesthesia by integrating traditional Chinese and Western medicine
-
Zhang XT (ed): Science Press, Beijing
-
Qian XZ: Progress in scientific research on acupuncture, moxibustion and acupuncture anesthesia by integrating traditional Chinese and Western medicine, in: Zhang XT (ed): Research on Acupuncture, Moxibustion, and Acupuncture Anesthesia, Science Press, Beijing, 1986, pp. 1-18.
-
(1986)
Research on Acupuncture, Moxibustion, and Acupuncture Anesthesia
, pp. 1-18
-
-
Qian, X.Z.1
-
2
-
-
0023514771
-
Advances of research on the mechanism of acupuncture and moxibustion
-
In Chinese
-
Tang D: Advances of research on the mechanism of acupuncture and moxibustion. Acup Res, 1987; 4: 278-284. (In Chinese)
-
(1987)
Acup Res
, vol.4
, pp. 278-284
-
-
Tang, D.1
-
4
-
-
0024233360
-
The advances and prospects in physiological and biophysical approaches of acupuncture meridian system
-
In Chinese
-
Zhu ZX: The advances and prospects in physiological and biophysical approaches of acupuncture meridian system. Acup Res, 1988; (2): 81-89. (In Chinese)
-
(1988)
Acup Res
, Issue.2
, pp. 81-89
-
-
Zhu, Z.X.1
-
5
-
-
0025159730
-
Studies on the Phenomenon of Latent Propagated Sensation Along Channel (LPSC) by Combining Applied Knocks, Measurement of Resistance and Recording of Electric Current
-
In Chinese
-
Weng TL, Lu MF, Lu XQ, Lu WY: Studies on the Phenomenon of Latent Propagated Sensation Along Channel (LPSC) by Combining Applied Knocks, Measurement of Resistance and Recording of Electric Current. Acup Res, 1990; (1): 82-84. (In Chinese)
-
(1990)
Acup Res
, Issue.1
, pp. 82-84
-
-
Weng, T.L.1
Lu, M.F.2
Lu, X.Q.3
Lu, W.Y.4
-
6
-
-
0021287115
-
Stretch-activated single ion channel currents in tissue-cultured embryonic chick skeletal muscle
-
Guharay F, Sachs F: Stretch-activated single ion channel currents in tissue-cultured embryonic chick skeletal muscle. J Physiol (London), 1984; 352: 685-701.
-
(1984)
J Physiol (London)
, vol.352
, pp. 685-701
-
-
Guharay, F.1
Sachs, F.2
-
7
-
-
0021892579
-
Mechano-transducer ion channels in chick skeletal muscle: The effects of extracellular pH
-
Guharay F, Sachs F: Mechano-transducer ion channels in chick skeletal muscle: the effects of extracellular pH. J Physiol (London), 1985; 363: 119-134.
-
(1985)
J Physiol (London)
, vol.363
, pp. 119-134
-
-
Guharay, F.1
Sachs, F.2
-
8
-
-
0025186789
-
Mechanosensitive ion channels
-
Morris CE: Mechanosensitive ion channels. J Membrane Biol, 1990; 113: 93-107.
-
(1990)
J Membrane Biol
, vol.113
, pp. 93-107
-
-
Morris, C.E.1
-
9
-
-
0027295838
-
Pressure-clamp technique for measurement of the relaxation kinetics of mechanosensitive channels
-
McBride DW Jr, Hamill OP: Pressure-clamp technique for measurement of the relaxation kinetics of mechanosensitive channels. TINS, 1993; (16): 341-345.
-
(1993)
TINS
, Issue.16
, pp. 341-345
-
-
McBride Jr., D.W.1
Hamill, O.P.2
-
10
-
-
7344228106
-
Mechanical Transduction: Unification?
-
Sachs F: Mechanical Transduction: Unification? NIPS, 1986; (1): 98-100.
-
(1986)
NIPS
, Issue.1
, pp. 98-100
-
-
Sachs, F.1
-
11
-
-
0003707007
-
-
Foreign Languages Press, Beijing
-
Beijing College of Traditional Chinese Medicine, Shanghai College of Traditional Chinese Medicine, Nanjing College of Traditional Chinese Medicine, the Acupuncture Institute of the Academy of Traditional Chinese Medicine: Essentials of Chinese Acupuncture. Foreign Languages Press, Beijing, 1980, pp. 301-310.
-
(1980)
Essentials of Chinese Acupuncture
, pp. 301-310
-
-
-
12
-
-
0019441262
-
Improved patch clamp techniques for high resolution current recording from cells and cell-free membrane patches
-
Hamill OP, Marty A, Neher E, Sakmann B, Sigworth FJ: Improved patch clamp techniques for high resolution current recording from cells and cell-free membrane patches. Pflugers Arch (Euro J Physiol), 1981; 391: 85-100.
-
(1981)
Pflugers Arch (Euro J Physiol)
, vol.391
, pp. 85-100
-
-
Hamill, O.P.1
Marty, A.2
Neher, E.3
Sakmann, B.4
Sigworth, F.J.5
-
13
-
-
0013611017
-
Towards molecular mechanism of activation in mechanosensitive ion channels
-
Ito F (ed): Springer-Verlag, Berlin
-
Sokabe M, Sachs F: Towards molecular mechanism of activation in mechanosensitive ion channels, in: Ito F (ed): Advances in Comparative and Environmental Physiology. Springer-Verlag, Berlin, 1992, pp. 55-76.
-
(1992)
Advances in Comparative and Environmental Physiology
, pp. 55-76
-
-
Sokabe, M.1
Sachs, F.2
-
14
-
-
0001030282
-
-
Corey DP, Roper SD (eds). Rockefeller University Press, New York
-
Sachs F: Sensory Transduction, Corey DP, Roper SD (eds). Rockefeller University Press, New York, 1992, pp. 242-260. Cited in:
-
(1992)
Sensory Transduction
, pp. 242-260
-
-
Sachs, F.1
-
15
-
-
0027295838
-
Pressure-clamp technique for measurement of the relaxation kinetics of mechanosensitive channels
-
McBride DW Jr, Hamill OP: Pressure-clamp technique for measurement of the relaxation kinetics of mechanosensitive channels. TINS, 1993; 16: 341-345.
-
(1993)
TINS
, vol.16
, pp. 341-345
-
-
McBride Jr., D.W.1
Hamill, O.P.2
-
16
-
-
0022551270
-
Biophysical studies of mechano-receptors
-
Grigg P: Biophysical studies of mechano-receptors. J Appl Physiol, 1986; 40: 1107-1115.
-
(1986)
J Appl Physiol
, vol.40
, pp. 1107-1115
-
-
Grigg, P.1
-
17
-
-
0016838077
-
Diagnostic acupuncture using a new skin conductance monitor
-
Fieldman EJ: Diagnostic acupuncture using a new skin conductance monitor. Amer J Acupun, 1975; 3: 161-162.
-
(1975)
Amer J Acupun
, vol.3
, pp. 161-162
-
-
Fieldman, E.J.1
|