Effective dose in diagnostic radiology as a function of x-ray beam filtration for a constant exit dose and constant film density

Author keywords

Effective dose; Filtration; Half value layer; Hvl; Radiation protection

Indexed keywords

DIAGNOSTIC RADIOGRAPHY; FILTRATION; HOSPITALS; RADIATION PROTECTION; RARE EARTHS; RISK ASSESSMENT; STOCHASTIC MODELS; STOCHASTIC SYSTEMS; X RAY TUBES; X RAYS;

EID: 0031832383     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598260     Document Type: Article
Times cited : (22)

References (37)
  • 1
    • 0004584079 scopus 로고
    • The quantity of radiation received by the reproductive organs of patients during routine diagnostic x-ray examinations
    • R. W. Stanford and J. Vance, "The quantity of radiation received by the reproductive organs of patients during routine diagnostic x-ray examinations," Br J. Radiol. 28, 266 (1955).
    • (1955) Br J. Radiol. , vol.28 , pp. 266
    • Stanford, R.W.1    Vance, J.2
  • 2
    • 33744675602 scopus 로고
    • The effect of field size on the dose to the patient in diagnostic radiology
    • J. L. Haybittle, "The effect of field size on the dose to the patient in diagnostic radiology," Br. J. Radiol. 30, 663 (1957).
    • (1957) Br. J. Radiol. , vol.30 , pp. 663
    • Haybittle, J.L.1
  • 3
    • 0041730928 scopus 로고
    • Dose in diagnostic radiology the effects of changes in kilovoltage and filtration
    • G. M. Ardan and H. E. Crooks, "Dose in diagnostic radiology the effects of changes in kilovoltage and filtration," Br. J. Radiol. 35, 172 (1962).
    • (1962) Br. J. Radiol. , vol.35 , pp. 172
    • Ardan, G.M.1    Crooks, H.E.2
  • 4
  • 5
    • 0017876183 scopus 로고
    • Reduction in patient exposure by use of heavy elements as radiation filters in diagnostic radiology
    • J. E. Villagran, B. B. Hobbs, and K. W Taylor, "Reduction in patient exposure by use of heavy elements as radiation filters in diagnostic radiology," Radiology 127, 249 (1978).
    • (1978) Radiology , vol.127 , pp. 249
    • Villagran, J.E.1    Hobbs, B.B.2    Taylor, K.W.3
  • 6
    • 0019393788 scopus 로고
    • Contrast effects of a gadolinium filter
    • A. E. Burgess, "Contrast effects of a gadolinium filter," Med Phys. 8, 203 (1981).
    • (1981) Med Phys. , vol.8 , pp. 203
    • Burgess, A.E.1
  • 7
    • 0019936945 scopus 로고
    • The optimization of signal detectability in digital fluoroscopy
    • R. G Zamenhof, "The optimization of signal detectability in digital fluoroscopy," Med Phys. 9, 688 (1982).
    • (1982) Med Phys. , vol.9 , pp. 688
    • Zamenhof, R.G.1
  • 9
    • 0020701367 scopus 로고
    • Effect of tungsten absorption edge filter on diagnostic x-ray spectra, image quality and absorbed dose to the patient
    • C Yamaguchi, T. Yanamoto, H. Terada, and M. Akisada, "Effect of tungsten absorption edge filter on diagnostic x-ray spectra, image quality and absorbed dose to the patient," Phys. Med Biol. 28, 223 (1983).
    • (1983) Phys. Med Biol. , vol.28 , pp. 223
    • Yamaguchi, C.1    Yanamoto, T.2    Terada, H.3    Akisada, M.4
  • 10
    • 0021948754 scopus 로고
    • Physical measurements of heavy metal filter performance
    • A. E. Burgess, "Physical measurements of heavy metal filter performance," Med. Phys. 12, 225 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 225
    • Burgess, A.E.1
  • 11
    • 0022595654 scopus 로고
    • Filter materials for dose reduction in screen-film radiography
    • K. Koedooder and H. Venema, "Filter materials for dose reduction in screen-film radiography," Phys. Med. Biol. 31, 585 (1986).
    • (1986) Phys. Med. Biol. , vol.31 , pp. 585
    • Koedooder, K.1    Venema, H.2
  • 12
    • 0023733658 scopus 로고
    • The influence of tube filtration and potential on patient dose during x-ray examinations
    • P. C. Shrimpton, D. G. Jones, and B. F. Wall, "The influence of tube filtration and potential on patient dose during x-ray examinations," Phys. Med. Biol. 33, 1205-1212 (1988)
    • (1988) Phys. Med. Biol. , vol.33 , pp. 1205-1212
    • Shrimpton, P.C.1    Jones, D.G.2    Wall, B.F.3
  • 14
    • 0024413015 scopus 로고
    • Comparison of performance characteristics of conventional and K-edge filters in general diagnostic radiology
    • H. D. Nagel, "Comparison of performance characteristics of conventional and K-edge filters in general diagnostic radiology," Phys. Med. Biol. 34, 1269-1287 (1989).
    • (1989) Phys. Med. Biol. , vol.34 , pp. 1269-1287
    • Nagel, H.D.1
  • 15
    • 0026658443 scopus 로고
    • Radiation dose reduction in diagnostic x-ray procedures
    • L. J. Regano and R. A. Sutton, "Radiation dose reduction in diagnostic x-ray procedures," Phys. Med. Biol. 37, 1773 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1773
    • Regano, L.J.1    Sutton, R.A.2
  • 16
    • 0028566068 scopus 로고
    • Physical parameters for patient dose reduction with x-ray filtration in diagnostic radiology
    • L. J. Schreiner, N. Biais, J-P. Bissonnette, and E. B. Podgorsak, "Physical parameters for patient dose reduction with x-ray filtration in diagnostic radiology," Radiol. Oncol. 28, 209 (1994)
    • (1994) Radiol. Oncol. , vol.28 , pp. 209
    • Schreiner, L.J.1    Biais, N.2    Bissonnette, J.-P.3    Podgorsak, E.B.4
  • 18
    • 85027219865 scopus 로고    scopus 로고
    • HHS Publication (FDA) 80-8035 (Rockville, MD:CDRH, 1980)
    • HHS Publication (FDA) 80-8035 (Rockville, MD:CDRH, 1980).
  • 19
    • 85027236877 scopus 로고    scopus 로고
    • HPA Publication TRG-32 (The Hospital Physicist's Association, London, 1980)
    • HPA Publication TRG-32 (The Hospital Physicist's Association, London, 1980).
  • 25
    • 0019453564 scopus 로고
    • Central axis depth dose data for diagnostic radiology
    • R. M. Harrison, "Central axis depth dose data for diagnostic radiology," Phys. Med. Biol. 26, 657 (1981).
    • (1981) Phys. Med. Biol. , vol.26 , pp. 657
    • Harrison, R.M.1
  • 26
    • 0345719531 scopus 로고
    • Conversion of depth dose from one F.S.D. to another
    • J. E. Burns, "Conversion of depth dose from one F.S.D. to another," Br. J. Radiol. 31, 643 (1958).
    • (1958) Br. J. Radiol. , vol.31 , pp. 643
    • Burns, J.E.1
  • 27
    • 0023629145 scopus 로고
    • An improved method for estimating the entrance exposure in diagnostic radiographic examinations
    • R. G. Zamenhof, "An improved method for estimating the entrance exposure in diagnostic radiographic examinations," Am J. Radiol. 149, 631-637 (1987).
    • (1987) Am J. Radiol. , vol.149 , pp. 631-637
    • Zamenhof, R.G.1
  • 29
    • 0028127040 scopus 로고
    • On the primary barrier in diagnostic x-ray shielding
    • A Report of Task Group 9 of the Diagnostic Imaging Committee of the AAPM
    • R. L. Dixon, "On the primary barrier in diagnostic x-ray shielding," A Report of Task Group 9 of the Diagnostic Imaging Committee of the AAPM, Med. Phys. 21, 1785-1793 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1785-1793
    • Dixon, R.L.1
  • 30
    • 85027240773 scopus 로고    scopus 로고
    • private communication
    • R. L. Dixon, private communication.
    • Dixon, R.L.1
  • 31
    • 0025221903 scopus 로고
    • E, in diagnostic radiology
    • E, in diagnostic radiology," Med. Phys. 17, 998-1003 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 998-1003
    • Huda, W.1    Bissessur, K.2
  • 33
    • 0004754562 scopus 로고
    • Determination of half value layer
    • E. D. Trout, J. P. Kelley, and A. C. Lucas, "Determination of half value layer," Am J. Radiol. 84, 729-740 (1960).
    • (1960) Am J. Radiol. , vol.84 , pp. 729-740
    • Trout, E.D.1    Kelley, J.P.2    Lucas, A.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.