메뉴 건너뛰기




Volumn 12, Issue 4, 1998, Pages 442-444

Cerebral oxygen saturation monitoring in an infant undergoing ICD implantation

Author keywords

Cerebral monitoring; Implantable cardioverter defibrillator; Long QT syndrome; Near infrared spectroscopy

Indexed keywords

ARTICLE; BRAIN OXYGEN CONSUMPTION; CASE REPORT; CENTRAL VENOUS PRESSURE; CHILD; DEFIBRILLATOR; FEMALE; HEART ARREST; HUMAN; IMPLANTATION; INFRARED SPECTROSCOPY; OXYGEN SATURATION; PRIORITY JOURNAL; STERNOTOMY;

EID: 0031830292     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1053-0770(98)90201-4     Document Type: Article
Times cited : (5)

References (20)
  • 1
    • 0028966406 scopus 로고
    • Randomized study of implantable defibrillator as first-choice therapy vs conventional strategy in postinfarct sudden death survivors
    • Wever EF, Hauer RN, van Capelle FL, et al: Randomized study of implantable defibrillator as first-choice therapy vs conventional strategy in postinfarct sudden death survivors. Circulation 91:2195-2203, 1995
    • (1995) Circulation , vol.91 , pp. 2195-2203
    • Wever, E.F.1    Hauer, R.N.2    Van Capelle, F.L.3
  • 2
    • 0027528936 scopus 로고
    • Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients
    • Silka MJ, Kron J, Dunnigan A, Dick M: Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients. Circulation 87:800-807, 1993
    • (1993) Circulation , vol.87 , pp. 800-807
    • Silka, M.J.1    Kron, J.2    Dunnigan, A.3    Dick, M.4
  • 3
    • 0030978787 scopus 로고    scopus 로고
    • Cognitive dysfnction after ventricular fibrillation during implantable cardioverter-defibrillator procedures is related to duration of the reperfusion interval
    • Murkin JM, Baird DL, Martzke JS, Yee R: Cognitive dysfnction after ventricular fibrillation during implantable cardioverter-defibrillator procedures is related to duration of the reperfusion interval. Anesth Analg 84:1186-1192, 1997
    • (1997) Anesth Analg , vol.84 , pp. 1186-1192
    • Murkin, J.M.1    Baird, D.L.2    Martzke, J.S.3    Yee, R.4
  • 4
    • 0030927812 scopus 로고    scopus 로고
    • Cerebral hemoglobin and optical path length influence near-infrared spectroscopy measurement of cerebral oxygen saturation
    • Kurth CD, Uher B: Cerebral hemoglobin and optical path length influence near-infrared spectroscopy measurement of cerebral oxygen saturation. Anesth Analg 84:1297-1305, 1997
    • (1997) Anesth Analg , vol.84 , pp. 1297-1305
    • Kurth, C.D.1    Uher, B.2
  • 5
    • 0025234791 scopus 로고
    • Quantitation of cerebral blood volume in human infants by near-infrared spectroscopy
    • Wyatt JS, Cope M, Delpy DT, et al: Quantitation of cerebral blood volume in human infants by near-infrared spectroscopy. J Appl Physiol 68:1086-1091, 1990
    • (1990) J Appl Physiol , vol.68 , pp. 1086-1091
    • Wyatt, J.S.1    Cope, M.2    Delpy, D.T.3
  • 7
    • 0025054040 scopus 로고
    • Electroencephalographic changes during brief cardiac arrest in humans
    • Clute HL, Levy WJ: Electroencephalographic changes during brief cardiac arrest in humans. Anesthesiology 73:821-825, 1990
    • (1990) Anesthesiology , vol.73 , pp. 821-825
    • Clute, H.L.1    Levy, W.J.2
  • 8
    • 13144264283 scopus 로고
    • Is DFT testing safe?
    • Singer J: Is DFT testing safe? Pace 12:234-235, 1992
    • (1992) Pace , vol.12 , pp. 234-235
    • Singer, J.1
  • 9
    • 4243972581 scopus 로고
    • Prolonged EEG-depression by repetitive defibrillation testings in ICD implantation
    • Heil T, Spies C, Rieger A, et al: Prolonged EEG-depression by repetitive defibrillation testings in ICD implantation. Anesthesiology 77:A161, 1992
    • (1992) Anesthesiology , vol.77
    • Heil, T.1    Spies, C.2    Rieger, A.3
  • 10
    • 23444453033 scopus 로고
    • Electroencephalography monitoring during implantation of an automatic implantable cardioverterdefibrillator. Effects of repetitive cerebral ischemia on cortex cerebral activity
    • Spies C, Heil T, Neumann T, Kramer S: Electroencephalography monitoring during implantation of an automatic implantable cardioverterdefibrillator. Effects of repetitive cerebral ischemia on cortex cerebral activity. J Cardiothorac Vase Anesth 8:184, 1994 (suppl 2)
    • (1994) J Cardiothorac Vase Anesth , vol.8 , Issue.2 SUPPL. , pp. 184
    • Spies, C.1    Heil, T.2    Neumann, T.3    Kramer, S.4
  • 11
    • 0028127829 scopus 로고
    • Evoked potential monitoring during repeatedly induced ventricular fibrillation for internal defibrillator implantation
    • Haussmann R, Polarz H, Rauch H, et al: Evoked potential monitoring during repeatedly induced ventricular fibrillation for internal defibrillator implantation. J Cardiothorac Vase Anesth 8:61-63, 1994
    • (1994) J Cardiothorac Vase Anesth , vol.8 , pp. 61-63
    • Haussmann, R.1    Polarz, H.2    Rauch, H.3
  • 12
    • 0028955295 scopus 로고
    • Implantable cardioverter-defibrillator: Evaluation of neurologic outcome and EEG changes during implantation
    • Adams DC, Heyer EJ, Emerson RG, et al: Implantable cardioverter-defibrillator: Evaluation of neurologic outcome and EEG changes during implantation. J Thorac Cardiovasc Surg 109:563-573, 1995
    • (1995) J Thorac Cardiovasc Surg , vol.109 , pp. 563-573
    • Adams, D.C.1    Heyer, E.J.2    Emerson, R.G.3
  • 13
    • 0030004402 scopus 로고    scopus 로고
    • The impact of repeated short episodes of circulatory arrest on cerebral function. Reassuring electroencephalographic (EEG) findings during defibrillator threshold testing at defibrillator implantation
    • Vriens EM, Bakker PFA, Vries JW de, et al: The impact of repeated short episodes of circulatory arrest on cerebral function. Reassuring electroencephalographic (EEG) findings during defibrillator threshold testing at defibrillator implantation. EEG Clin Neurophysiol 96:236-242, 1996
    • (1996) EEG Clin Neurophysiol , vol.96 , pp. 236-242
    • Vriens, E.M.1    Bakker, P.F.A.2    De Vries, J.W.3
  • 14
    • 0039526151 scopus 로고
    • Neuromonitoring to improve the safety of defibrillation threshold testing
    • Edmonds HL, Rodriguez RA, Singer I, et al: Neuromonitoring to improve the safety of defibrillation threshold testing. Stroke 25:734, 1994
    • (1994) Stroke , vol.25 , pp. 734
    • Edmonds, H.L.1    Rodriguez, R.A.2    Singer, I.3
  • 15
    • 0025365380 scopus 로고
    • Reperfusion hyperoxia in brain after circulatory arrest in humans
    • Smith DS, Levy WJ, Maris M, Chance B: Reperfusion hyperoxia in brain after circulatory arrest in humans. Anesthesiology 73:12-19, 1990
    • (1990) Anesthesiology , vol.73 , pp. 12-19
    • Smith, D.S.1    Levy, W.J.2    Maris, M.3    Chance, B.4
  • 16
    • 0031238887 scopus 로고    scopus 로고
    • Neuromonitoring in defibrillation threshold testing. A comparison between near-infrared spectroscopy and jugular bulb oximetry
    • de Vries JW, Visser GH, Bakker PFA: Neuromonitoring in defibrillation threshold testing. A comparison between near-infrared spectroscopy and jugular bulb oximetry. J Clin Monit 13:303-307, 1997
    • (1997) J Clin Monit , vol.13 , pp. 303-307
    • De Vries, J.W.1    Visser, G.H.2    Bakker, P.F.A.3
  • 17
    • 0029256674 scopus 로고
    • Nichtinvasive Uberwachung der regionalen zerebralen Sauerstoffsattigung; Erfahrungen aus der Intensivmedizin
    • Berlin
    • Litscher G, Schwarz G, Jobstmann R, et al: Nichtinvasive Uberwachung der regionalen zerebralen Sauerstoffsattigung; Erfahrungen aus der Intensivmedizin. Biomed Tech (Berlin) 40:70-75, 1995
    • (1995) Biomed Tech , vol.40 , pp. 70-75
    • Litscher, G.1    Schwarz, G.2    Jobstmann, R.3
  • 18
    • 84995178365 scopus 로고
    • A comparative study of two near-infrared spectrophotometers for the assessment of cerebral haemodynamics
    • Colier WNJM, van Haaren NJ, Oeseburg B: A comparative study of two near-infrared spectrophotometers for the assessment of cerebral haemodynamics. Acta Anaesthesiol Scand 107:101-105, 1995 (suppl)
    • (1995) Acta Anaesthesiol Scand , vol.107 , Issue.SUPPL. , pp. 101-105
    • Colier, W.N.J.M.1    Van Haaren, N.J.2    Oeseburg, B.3
  • 19
    • 0028910612 scopus 로고
    • Extracerebral absorption of near-infrared light influences the detection of increased cerebral oxygenation monitored by near-infrared spectroscopy
    • Germon TJ, Young AE, Manara AR, Nelson RJ: Extracerebral absorption of near-infrared light influences the detection of increased cerebral oxygenation monitored by near-infrared spectroscopy. J Neurol Neurosurg Psychiatry 58:477-479, 1995
    • (1995) J Neurol Neurosurg Psychiatry , vol.58 , pp. 477-479
    • Germon, T.J.1    Young, A.E.2    Manara, A.R.3    Nelson, R.J.4
  • 20
    • 0031040870 scopus 로고    scopus 로고
    • The contribution of extracranial blood oxygenation on near-infrared spectroscopy during carotid thrombendarterectomy
    • Grubhofer G, Lassnigg A, Manlik F, et al: The contribution of extracranial blood oxygenation on near-infrared spectroscopy during carotid thrombendarterectomy. Anaesthesia 52:116-120, 1997
    • (1997) Anaesthesia , vol.52 , pp. 116-120
    • Grubhofer, G.1    Lassnigg, A.2    Manlik, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.