메뉴 건너뛰기




Volumn 43, Issue 8, 1998, Pages 2393-2395

Gap-stepped MLC leaves with filler blades can eliminate tongue-and- groove underdoses when delivering IMRT with maximum efficiency

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; COLLIMATOR; PRIORITY JOURNAL; RADIATION ABSORPTION; RADIATION DEPTH DOSE; RADIATION DOSE;

EID: 0031827566     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/43/8/029     Document Type: Article
Times cited : (5)

References (5)
  • 1
    • 0028346915 scopus 로고
    • The design and performance characteristies of a multileaf collimator
    • Jordan T J and Williams P C 1994 The design and performance characteristies of a multileaf collimator Phys. Med. Biol. 39 231-51
    • (1994) Phys. Med. Biol. , vol.39 , pp. 231-251
    • Jordan, T.J.1    Williams, P.C.2
  • 2
    • 0031952132 scopus 로고    scopus 로고
    • Configuration options for intensity-modulated therapy using multiple static fields shaped by a multileaf collimator
    • Webb S 1998a Configuration options for intensity-modulated therapy using multiple static fields shaped by a multileaf collimator Phys. Med. Biol. 43 241-60
    • (1998) Phys. Med. Biol. , vol.43 , pp. 241-260
    • Webb, S.1
  • 3
    • 0031807849 scopus 로고    scopus 로고
    • Configuration options for intensity radiation using multiple static fields shaped by a multileaf collimator. II: Constraints and limitations on 2D modulation
    • Webb S 1998b Configuration options for intensity radiation using multiple static fields shaped by a multileaf collimator. II: Constraints and limitations on 2D modulation Phys. Med. Biol. 43 1481-95
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1481-1495
    • Webb, S.1
  • 4
    • 0030888540 scopus 로고    scopus 로고
    • The ettect of stair-step leaf transmission on the 'tongue-and groove problem' in dynamic radiotherapy with a multileaf collimator
    • Webb S, Bortfield T, Stein J and Convery D J 1997 The ettect of stair-step leaf transmission on the 'tongue-and groove problem' in dynamic radiotherapy with a multileaf collimator Phys. Med. Biol. 42 595-602
    • (1997) Phys. Med. Biol. , vol.42 , pp. 595-602
    • Webb, S.1    Bortfield, T.2    Stein, J.3    Convery, D.J.4
  • 5
    • 0031949109 scopus 로고    scopus 로고
    • Design considerations lor the sides of multileaf collimator leaves
    • Wu C X 1998 Design considerations lor the sides of multileaf collimator leaves Phys. Med. Biol. 43 1335-42
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1335-1342
    • Wu, C.X.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.