메뉴 건너뛰기




Volumn 136, Issue 2, 1998, Pages 345-351

Treatment of long dissections by use of a single long or multiple short stents: Clinical and angiographic follow-up

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; CLINICAL EXAMINATION; CORONARY ARTERY DILATATION; CORONARY ARTERY OBSTRUCTION; FEMALE; FOLLOW UP; HEART INFARCTION; HEART MUSCLE ISCHEMIA; HUMAN; IMPLANTATION; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; STENT;

EID: 0031823991     PISSN: 00028703     EISSN: None     Source Type: Journal    
DOI: 10.1053/hj.1998.v136.89578     Document Type: Article
Times cited : (16)

References (17)
  • 2
    • 0027934377 scopus 로고
    • A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Fishman D, Leon M, Baim D, et al. A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 1994;331:496-501.
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fishman, D.1    Leon, M.2    Baim, D.3
  • 3
    • 0028643558 scopus 로고
    • Four-year experience with Palmaz-Schatz stenting in coronary angioplasty complicated by dissection with threatened or present vessel closure
    • Schömig A, Kastrati A, Mudra H, et al. Four-year experience with Palmaz-Schatz stenting in coronary angioplasty complicated by dissection with threatened or present vessel closure. Circulation 1994;90:2716-24.
    • (1994) Circulation , vol.90 , pp. 2716-2724
    • Schömig, A.1    Kastrati, A.2    Mudra, H.3
  • 4
    • 0027436632 scopus 로고
    • Clinical and angiographic outcomes after coronary artery stenting for acute or threatened closure after percutaneous transluminal coronary angioplasty: Initial results with a balloon expandable stainless steel design
    • Hearn JA, King SB III, Douglas JS Jr, Carlin SF, Lembo NJ, Ghazzal ZMB. Clinical and angiographic outcomes after coronary artery stenting for acute or threatened closure after percutaneous transluminal coronary angioplasty: initial results with a balloon expandable stainless steel design. Circulation 1993;88:2086-96.
    • (1993) Circulation , vol.88 , pp. 2086-2096
    • Hearn, J.A.1    King III, S.B.2    Douglas Jr., J.S.3    Carlin, S.F.4    Lembo, N.J.5    Ghazzal, Z.M.B.6
  • 5
    • 0027479247 scopus 로고
    • Intracoronary stenting compared with conventional therapy for abrupt vessel closure complicating coronary angioplasty: A matched case-control study
    • Lincoff AM, Topol EJ, Chapekis AT, George BS, Candela RJ, Muller DWM, et al. Intracoronary stenting compared with conventional therapy for abrupt vessel closure complicating coronary angioplasty: a matched case-control study. J Am Coll Cardiol 1993;21:866-75.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 866-875
    • Lincoff, A.M.1    Topol, E.J.2    Chapekis, A.T.3    George, B.S.4    Candela, R.J.5    Muller, D.W.M.6
  • 6
    • 0023760740 scopus 로고
    • Emergency stenting for acute occlusion after coronary balloon angioplasty
    • Sigwart U, Urban P, Golf S, Kaufmann U, Imbert C, Fischer A, et al. Emergency stenting for acute occlusion after coronary balloon angioplasty. Circulation 1988;78:1121-7
    • (1988) Circulation , vol.78 , pp. 1121-1127
    • Sigwart, U.1    Urban, P.2    Golf, S.3    Kaufmann, U.4    Imbert, C.5    Fischer, A.6
  • 7
    • 0026507461 scopus 로고
    • Intracoronary stenting for acute and threatened closure complicating percutaneous transluminal coronary angioplasty
    • Roubin GS, Cannon AD, Agrawal SK, Macander PJ, Dean LS, Boxley WA, et al. Intracoronary stenting for acute and threatened closure complicating percutaneous transluminal coronary angioplasty. Circulation 1992;85:916-27
    • (1992) Circulation , vol.85 , pp. 916-927
    • Roubin, G.S.1    Cannon, A.D.2    Agrawal, S.K.3    Macander, P.J.4    Dean, L.S.5    Boxley, W.A.6
  • 8
    • 0026802432 scopus 로고
    • Emergent use of balloon-expandable coronary artery stenting for failed PICA
    • Hermann HC, Buchbinder M, Clemen MW, et al. Emergent use of balloon-expandable coronary artery stenting for failed PICA. Circulation 1992;86:812-9.
    • (1992) Circulation , vol.86 , pp. 812-819
    • Hermann, H.C.1    Buchbinder, M.2    Clemen, M.W.3
  • 10
    • 0008545859 scopus 로고    scopus 로고
    • Experimental evaluation of a new single wire stainless steel fishschale coronary stent (Freedom)
    • Wang K, Verbeken E, Mukherjee S, et al. Experimental evaluation of a new single wire stainless steel fishschale coronary stent (Freedom). J Invas Cardiol 1996;357-62.
    • (1996) J Invas Cardiol , pp. 357-362
    • Wang, K.1    Verbeken, E.2    Mukherjee, S.3
  • 11
    • 26844444414 scopus 로고    scopus 로고
    • The Freedom coronary stent
    • Serruys PW, editor. London: Martin Dunitz
    • De Scheerder I. The Freedom coronary stent. In: Serruys PW, editor. Handbook of coronary stents. London: Martin Dunitz; 1997. p. 101-10.
    • (1997) Handbook of Coronary Stents , pp. 101-110
    • De Scheerder, I.1
  • 13
    • 0002494825 scopus 로고
    • The improvement of vessel quantification with image processing equipment for high resolution digital angiography
    • Lemke HV, editor. Berlin: Springer-Verlag
    • Barth K, Eicker B, Bittner U, Marhoff P. The improvement of vessel quantification with image processing equipment for high resolution digital angiography. In: Lemke HV, editor. Computer assisted radiology. Berlin: Springer-Verlag; 1989. p. 220-5.
    • (1989) Computer Assisted Radiology , pp. 220-225
    • Barth, K.1    Eicker, B.2    Bittner, U.3    Marhoff, P.4
  • 15
    • 0018233679 scopus 로고
    • Coronary angiogram interpretation: Interobserver variability
    • Galbraith JE, Murphy ML, Desoyza N. Coronary angiogram interpretation: interobserver variability. JAMA 1981;240:2053-9.
    • (1981) JAMA , vol.240 , pp. 2053-2059
    • Galbraith, J.E.1    Murphy, M.L.2    Desoyza, N.3
  • 16
    • 0026066426 scopus 로고
    • Pitfalls in the determination of absolute dimensions using angiographic catheters as calibration devices in quantitative angiography
    • Fortin DF, Spero LA, Cusma JT, et al. Pitfalls in the determination of absolute dimensions using angiographic catheters as calibration devices in quantitative angiography. Am J Cardiol 1991;68:1176-82.
    • (1991) Am J Cardiol , vol.68 , pp. 1176-1182
    • Fortin, D.F.1    Spero, L.A.2    Cusma, J.T.3
  • 17
    • 0028010787 scopus 로고
    • Angiotensin converting enzyme inhibition with fosinopril sodium in the prevention of restenosis after coronary angioplasty
    • Desmet W, Vrolix M, De Scheerder I, Van Lierde J, Willems JL, Piessens J. Angiotensin converting enzyme inhibition with fosinopril sodium in the prevention of restenosis after coronary angioplasty. Circulation 1994;89:385-92.
    • (1994) Circulation , vol.89 , pp. 385-392
    • Desmet, W.1    Vrolix, M.2    De Scheerder, I.3    Van Lierde, J.4    Willems, J.L.5    Piessens, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.