메뉴 건너뛰기




Volumn 13, Issue 5, 1998, Pages 535-545

Clinical results of the midstem porous-coated anatomic uncemented femoral stem in primary total hip arthroplasty: A five- to nine-year prospective study

Author keywords

Acetabular cup; Midstem; Osteolysis

Indexed keywords

ACETABULUM; ADULT; ARTICLE; BONE PAIN; CONTROLLED STUDY; FEMALE; HUMAN; JOINT STABILITY; MAJOR CLINICAL STUDY; MALE; OSTEOLYSIS; POSTOPERATIVE COMPLICATION; PROSTHESIS LOOSENING; THIGH; TOTAL HIP PROSTHESIS; TREATMENT OUTCOME;

EID: 0031821504     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(98)90053-5     Document Type: Article
Times cited : (14)

References (20)
  • 1
    • 0026319943 scopus 로고
    • Noncemented porous-coated anatomic total hip arthroplasty
    • Dodge BM, Fitzrandolph R, Collins DN: Noncemented porous-coated anatomic total hip arthroplasty. Clin Orthop 269:16, 1991
    • (1991) Clin Orthop , vol.269 , pp. 16
    • Dodge, B.M.1    Fitzrandolph, R.2    Collins, D.N.3
  • 2
    • 0025285358 scopus 로고
    • Femoral stem fixation in hip replacement: A biomechanical comparison of cementless and cemented prostheses
    • Phillips TW, Messieh SS, McDonald PD: Femoral stem fixation in hip replacement: a biomechanical comparison of cementless and cemented prostheses. J Bone Joint Surg [Br] 72:431, 1990
    • (1990) J Bone Joint Surg [Br] , vol.72 , pp. 431
    • Phillips, T.W.1    Messieh, S.S.2    McDonald, P.D.3
  • 3
    • 0026739877 scopus 로고
    • The effect of femoral stem geometry on interface motion in uncemented porous-coated total hip prosthesis: A comparison of straight-stem and curved-stem designs
    • Callaghan JJ, Fulghum CS, Glisson RR, Stranne SK: The effect of femoral stem geometry on interface motion in uncemented porous-coated total hip prosthesis: a comparison of straight-stem and curved-stem designs. J Bone Joint Surg [Am] 74:839, 1992
    • (1992) J Bone Joint Surg [Am] , vol.74 , pp. 839
    • Callaghan, J.J.1    Fulghum, C.S.2    Glisson, R.R.3    Stranne, S.K.4
  • 4
    • 13144293284 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fracture: An end result study using a new method of result evaluation
    • Harris WH: Traumatic arthritis of the hip after dislocation and acetabular fracture: an end result study using a new method of result evaluation. J Bone Joint Surg [Am] 51:4, 1969
    • (1969) J Bone Joint Surg [Am] , vol.51 , pp. 4
    • Harris, W.H.1
  • 5
  • 6
    • 0027236336 scopus 로고
    • Bonegrafting for acetabular deficiency during primary and revision total hip arthroplasty: A radiographic and clinical analysis
    • Knight JL, Atwater RD, Grothaus L: Bonegrafting for acetabular deficiency during primary and revision total hip arthroplasty: a radiographic and clinical analysis. J Arthroplasty 8:371, 1993
    • (1993) J Arthroplasty , vol.8 , pp. 371
    • Knight, J.L.1    Atwater, R.D.2    Grothaus, L.3
  • 7
    • 0020524990 scopus 로고
    • Hip arthroplasty with a Moore prosthesis with porous coating: A five year study
    • Engh CA: Hip arthroplasty with a Moore prosthesis with porous coating: a five year study. Clin Orthop 176:52, 1983
    • (1983) Clin Orthop , vol.176 , pp. 52
    • Engh, C.A.1
  • 10
    • 0029148487 scopus 로고
    • Appositional bone bridging of primary gaps in the dome area of uncemented, porous acetabular components: A case report
    • Onsten I: Appositional bone bridging of primary gaps in the dome area of uncemented, porous acetabular components: a case report. J Arthroplasty 10:702, 1995
    • (1995) J Arthroplasty , vol.10 , pp. 702
    • Onsten, I.1
  • 11
    • 0030227642 scopus 로고    scopus 로고
    • Spontaneous resolution of soft-tissue interposition after closed reduction of hip endoprosthesis dislocation
    • Simonian PT, Green TM: Spontaneous resolution of soft-tissue interposition after closed reduction of hip endoprosthesis dislocation. Am J Orthop 25:642, 1996
    • (1996) Am J Orthop , vol.25 , pp. 642
    • Simonian, P.T.1    Green, T.M.2
  • 12
    • 0026324099 scopus 로고
    • Prospective study of porous-coated anatomic total hip arthroplasty
    • Alexiades MM, Clain MR, Bronson MJ: Prospective study of porous-coated anatomic total hip arthroplasty. Clin Orthop 269:205, 1991
    • (1991) Clin Orthop , vol.269 , pp. 205
    • Alexiades, M.M.1    Clain, M.R.2    Bronson, M.J.3
  • 13
    • 0026339386 scopus 로고
    • The noncemented porous-coated hip prosthesis; a three-year clinical follow-up study and roentgenographic analysis
    • Bands R, Pelker RR, Shine J, Bradburn H, Margolis R, Leach J: The noncemented porous-coated hip prosthesis; a three-year clinical follow-up study and roentgenographic analysis. Clin Orthop 269:209, 1991
    • (1991) Clin Orthop , vol.269 , pp. 209
    • Bands, R.1    Pelker, R.R.2    Shine, J.3    Bradburn, H.4    Margolis, R.5    Leach, J.6
  • 14
    • 0026560425 scopus 로고
    • Early failure of noncemented porous coated anatomic total hip arthroplasty
    • Mavic Z, Karpman RR: Early failure of noncemented porous coated anatomic total hip arthroplasty. Clin Orthop 278:116, 1992
    • (1992) Clin Orthop , vol.278 , pp. 116
    • Mavic, Z.1    Karpman, R.R.2
  • 15
    • 0027397479 scopus 로고
    • The porous-coated anatomic total hip prosthesis, inserted without cement: Results after five to seven years in a prospective study
    • Heekin RD, Callaghan JJ, Hopkinson WJ, Xenos JS: The porous-coated anatomic total hip prosthesis, inserted without cement: results after five to seven years in a prospective study. J Bone Joint Surg [Am] 75:77, 1993
    • (1993) J Bone Joint Surg [Am] , vol.75 , pp. 77
    • Heekin, R.D.1    Callaghan, J.J.2    Hopkinson, W.J.3    Xenos, J.S.4
  • 16
    • 0027416061 scopus 로고
    • Uncemented porous-coated anatomic total hip replacement: Results at six years in a consecutive series
    • Kim YH, Kim VE: Uncemented porous-coated anatomic total hip replacement: results at six years in a consecutive series. J Bone Joint Surg [Br] 75:6, 1993
    • (1993) J Bone Joint Surg [Br] , vol.75 , pp. 6
    • Kim, Y.H.1    Kim, V.E.2
  • 17
    • 0029083461 scopus 로고
    • Cemented collarless (Exeter-CPT) versus cementless collarless (PCA) femoral components: A 2 to 14-year follow-up evaluation
    • Weidenhielm LRA, Mikhail WEM, Nelissen RGH, Bauer TW: Cemented collarless (Exeter-CPT) versus cementless collarless (PCA) femoral components: a 2 to 14-year follow-up evaluation. J Arthroplasty 10: 592, 1995
    • (1995) J Arthroplasty , vol.10 , pp. 592
    • Weidenhielm, L.R.A.1    Mikhail, W.E.M.2    Nelissen, R.G.H.3    Bauer, T.W.4
  • 19
    • 0027311853 scopus 로고
    • The 3-6-year results of a modular noncemented low-bending stiffness hip implant: A preliminary study
    • Cameron HTJ: The 3-6-year results of a modular noncemented low-bending stiffness hip implant: a preliminary study. J Arthroplasty 8:239, 1993
    • (1993) J Arthroplasty , vol.8 , pp. 239
    • Cameron, H.T.J.1
  • 20
    • 0028220083 scopus 로고
    • Hip arthroplasty using the cementless CLS stem: A 2-4 year experience
    • Robinson RP, Lovell TP, Green TM: Hip arthroplasty using the cementless CLS stem: a 2-4 year experience. J Arthroplasty 9:177, 1995
    • (1995) J Arthroplasty , vol.9 , pp. 177
    • Robinson, R.P.1    Lovell, T.P.2    Green, T.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.