메뉴 건너뛰기




Volumn 40, Issue 1, 1998, Pages 89-98

Measurement of perfusion rate in human melanoma xenografts by contrast- enhanced magnetic resonance imaging

Author keywords

Contrast enhanced MRI; Kety equation; Melanoma xenograft; Perfusion rate

Indexed keywords

DECAY (ORGANIC); DERMATOLOGY; KINETICS; MAGNETIC RESONANCE IMAGING; ONCOLOGY; TUMORS;

EID: 0031814383     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910400113     Document Type: Article
Times cited : (44)

References (34)
  • 1
    • 0023909330 scopus 로고
    • Determinants of tumor blood flow: A review
    • R. K. Jain, Determinants of tumor blood flow: a review. Cancer Res. 48, 2641-2658 (1988).
    • (1988) Cancer Res. , vol.48 , pp. 2641-2658
    • Jain, R.K.1
  • 2
    • 0024408986 scopus 로고
    • Blood flow, oxygen and nutrient supply, and metabolic microenvironment of human tumors: A review
    • P. Vaupel, F. Kallinowski, P. Okunieff, Blood flow, oxygen and nutrient supply, and metabolic microenvironment of human tumors: a review. Cancer Res. 49, 6449-6465 (1989).
    • (1989) Cancer Res. , vol.49 , pp. 6449-6465
    • Vaupel, P.1    Kallinowski, F.2    Okunieff, P.3
  • 3
    • 0028239980 scopus 로고
    • Studies of Gd-DTPA relaxivity and proton exchange rates in tissue
    • K. M. Donahue, D. Burstein, W. J. Manning, M. L. Gray, Studies of Gd-DTPA relaxivity and proton exchange rates in tissue. Magn. Reson. Med. 32, 66-76 (1994).
    • (1994) Magn. Reson. Med. , vol.32 , pp. 66-76
    • Donahue, K.M.1    Burstein, D.2    Manning, W.J.3    Gray, M.L.4
  • 5
    • 0027577564 scopus 로고
    • Evaluation of tumor blood perfusion by dynamic MRI and CT in patients undergoing thermoradiotherapy
    • H. J. Feldmann, K. Sievers, J. Füller, M. Molls, E. Löhr, Evaluation of tumor blood perfusion by dynamic MRI and CT in patients undergoing thermoradiotherapy. Eur. J. Radiol. 16, 224-229 (1993).
    • (1993) Eur. J. Radiol. , vol.16 , pp. 224-229
    • Feldmann, H.J.1    Sievers, K.2    Füller, J.3    Molls, M.4    Löhr, E.5
  • 7
    • 0001609545 scopus 로고
    • Theory of blood-tissue exchange and its application to measurement of blood flow
    • S. S. Kety, Theory of blood-tissue exchange and its application to measurement of blood flow. Meth. Med. Res. 8, 223-227 (1960).
    • (1960) Meth. Med. Res. , vol.8 , pp. 223-227
    • Kety, S.S.1
  • 8
    • 0026553517 scopus 로고
    • Determination of changes in tumor blood perfusion after hydralazine treatment by dynamic paramagnetic-enhanced magnetic resonance imaging
    • C. A. Belfi, L.-L. Ting, S. J. Hassenbusch, M. Tefft, F. Q. H. Ngo, Determination of changes in tumor blood perfusion after hydralazine treatment by dynamic paramagnetic-enhanced magnetic resonance imaging. Int. J. Radiat. Oncol. Biol. Phys. 22, 477-482 (1992).
    • (1992) Int. J. Radiat. Oncol. Biol. Phys. , vol.22 , pp. 477-482
    • Belfi, C.A.1    Ting, L.-L.2    Hassenbusch, S.J.3    Tefft, M.4    Ngo, F.Q.H.5
  • 9
    • 0029979794 scopus 로고    scopus 로고
    • The relationship between partial pressure of oxygen and perfusion in two murine tumors after x-ray irradiation: A combined gadopentetate dimeglumine dynamic magnetic resonance imaging and in vivo electron paramagnetic resonance oximetry study
    • F. Goda, G. Bacic, J. A. O'Hara, B. Gallez, H. M. Swartz, J. F. Dunn, The relationship between partial pressure of oxygen and perfusion in two murine tumors after x-ray irradiation: a combined gadopentetate dimeglumine dynamic magnetic resonance imaging and in vivo electron paramagnetic resonance oximetry study. Cancer Res. 56, 3344-3349 (1996).
    • (1996) Cancer Res. , vol.56 , pp. 3344-3349
    • Goda, F.1    Bacic, G.2    O'Hara, J.A.3    Gallez, B.4    Swartz, H.M.5    Dunn, J.F.6
  • 10
    • 0029857166 scopus 로고    scopus 로고
    • Pharmacokinetic changes induced by vasomodulators in kidneys, livers, muscles, and implanted tumors in rats as measured by dynamic Gd-DTPA enhanced MRI
    • M.-Y. Su, Z. Wang, G. M. Roth, X. Lao, M. K. Samoszuk, O. Nalcioglu, Pharmacokinetic changes induced by vasomodulators in kidneys, livers, muscles, and implanted tumors in rats as measured by dynamic Gd-DTPA enhanced MRI. Magn. Reson. Med. 36, 868-877 (1996).
    • (1996) Magn. Reson. Med. , vol.36 , pp. 868-877
    • Su, M.-Y.1    Wang, Z.2    Roth, G.M.3    Lao, X.4    Samoszuk, M.K.5    Nalcioglu, O.6
  • 11
    • 0028356794 scopus 로고
    • Method for quantitative assessment of contrast agent uptake in dynamic contrast-enhanced MRI
    • K. Hittmair, G. Gomiscek, K. Langenberger, M. Recht, H. Imhof, J. Kramer, Method for quantitative assessment of contrast agent uptake in dynamic contrast-enhanced MRI. Magn. Reson. Med. 31, 567-571 (1994).
    • (1994) Magn. Reson. Med. , vol.31 , pp. 567-571
    • Hittmair, K.1    Gomiscek, G.2    Langenberger, K.3    Recht, M.4    Imhof, H.5    Kramer, J.6
  • 12
    • 0028005442 scopus 로고
    • Orthotopic human melanoma xenograft model systems for studies of tumor angiogenesis, pathophysiology, treatment sensitivity, and metastatic pattern
    • E. K. Rofstad, Orthotopic human melanoma xenograft model systems for studies of tumor angiogenesis, pathophysiology, treatment sensitivity, and metastatic pattern. Br. J. Cancer 70, 804-812 (1994).
    • (1994) Br. J. Cancer , vol.70 , pp. 804-812
    • Rofstad, E.K.1
  • 15
    • 0026604943 scopus 로고
    • Blood flow in six human melanoma xenograft lines with different growth characteristics
    • H. Lyng, A. Skretting, E. K. Rofstad, Blood flow in six human melanoma xenograft lines with different growth characteristics. Cancer Res. 52, 584-592 (1992).
    • (1992) Cancer Res. , vol.52 , pp. 584-592
    • Lyng, H.1    Skretting, A.2    Rofstad, E.K.3
  • 16
    • 0027215198 scopus 로고
    • Modification of tumor blood flow using the hypertensive agent, angiotensin II
    • G. M. Tozer, K. M. Shaffi, Modification of tumor blood flow using the hypertensive agent, angiotensin II. Br. J. Cancer 67, 981-988 (1993).
    • (1993) Br. J. Cancer , vol.67 , pp. 981-988
    • Tozer, G.M.1    Shaffi, K.M.2
  • 17
    • 0000832049 scopus 로고
    • Physiology
    • H. L. Foster, J. D. Small, J. G. Fox, Eds., Academic Press, New York
    • H. M. Kaplan, N. R. Brewer, W. H. Blair, Physiology, in "The Mouse in Biomedical Research" (H. L. Foster, J. D. Small, J. G. Fox, Eds.), pp. 247-292, Academic Press, New York, 1983.
    • (1983) The Mouse in Biomedical Research , pp. 247-292
    • Kaplan, H.M.1    Brewer, N.R.2    Blair, W.H.3
  • 18
    • 0028314232 scopus 로고
    • Magnetic resonance imaging of human melanoma xenografts in vivo: Proton spin-lattice and spin-spin relaxation times versus fractional tumor water content and fraction of necrotic tumor tissue
    • E. K. Rofstad, E. Steinsland, O. Kaalhus, Y. B. Chang, B. Hevik, H. Lyng, Magnetic resonance imaging of human melanoma xenografts in vivo: proton spin-lattice and spin-spin relaxation times versus fractional tumor water content and fraction of necrotic tumor tissue. Int. J. Radiat. Biol. 65, 387-402 (1994).
    • (1994) Int. J. Radiat. Biol. , vol.65 , pp. 387-402
    • Rofstad, E.K.1    Steinsland, E.2    Kaalhus, O.3    Chang, Y.B.4    Hevik, B.5    Lyng, H.6
  • 19
    • 0021324868 scopus 로고
    • Characteristics of gadolinium-DTPA complex: A potential NMR contrast agent
    • H.-J. Weinmann, R. C. Brasch, W.-R. Press, G. E. Wesbey, Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent. Am. J. Roentgenol. 142, 619-624 (1984).
    • (1984) Am. J. Roentgenol. , vol.142 , pp. 619-624
    • Weinmann, H.-J.1    Brasch, R.C.2    Press, W.-R.3    Wesbey, G.E.4
  • 20
    • 0025123896 scopus 로고
    • Fast MR imaging: Techniques and clinical applications
    • E. M. Haacke, J. A. Tkach, Fast MR imaging: techniques and clinical applications. Am. J. Roentgenol. 155, 951-964 (1990).
    • (1990) Am. J. Roentgenol. , vol.155 , pp. 951-964
    • Haacke, E.M.1    Tkach, J.A.2
  • 21
    • 0026527120 scopus 로고
    • Quantification of myocardial blood flow and extracellular volumes using a bolus injection of Gd-DTPA: Kinetic modeling in canine ischemic disease
    • L. D. Diesbourg, F. S. Prato, G. Wisenberg, D. J. Drost, T. P. Marshall, S. E. Carroll, B. O'Neill, Quantification of myocardial blood flow and extracellular volumes using a bolus injection of Gd-DTPA: kinetic modeling in canine ischemic disease. Magn. Reson. Med. 23, 239-253 (1992).
    • (1992) Magn. Reson. Med. , vol.23 , pp. 239-253
    • Diesbourg, L.D.1    Prato, F.S.2    Wisenberg, G.3    Drost, D.J.4    Marshall, T.P.5    Carroll, S.E.6    O'Neill, B.7
  • 22
    • 0021741851 scopus 로고
    • Blood flow effects in magnetic resonance imaging
    • L. Axel, Blood flow effects in magnetic resonance imaging. Am. J. Roentgenol. 143, 1157-1166 (1984).
    • (1984) Am. J. Roentgenol. , vol.143 , pp. 1157-1166
    • Axel, L.1
  • 23
    • 0001198399 scopus 로고
    • Capillary permeability to small solutes
    • E. M. Renkin, C. C. Michel, Eds., American Physiology Society, Bethesda, MD
    • C. Crone, D. G. Levitt, Capillary permeability to small solutes, in "Handbook of Physiology," Vol. 4 (E. M. Renkin, C. C. Michel, Eds.), pp. 411-466, American Physiology Society, Bethesda, MD, 1984.
    • (1984) Handbook of Physiology , vol.4 , pp. 411-466
    • Crone, C.1    Levitt, D.G.2
  • 24
    • 0013920609 scopus 로고
    • A model for capillary exchange
    • J. A. Johnson, T. A. Wilson, A model for capillary exchange. Am. J. Physiol. 210, 1299-1303 (1966).
    • (1966) Am. J. Physiol. , vol.210 , pp. 1299-1303
    • Johnson, J.A.1    Wilson, T.A.2
  • 26
    • 0017248152 scopus 로고
    • Tumor circulation. An experimental study in the rat with a comparison of different methods for estimation of tumor blood flow
    • I. Kjartansson, Tumor circulation. An experimental study in the rat with a comparison of different methods for estimation of tumor blood flow. Acta Chir. Scand. (Suppl.) 471, 1-74 (1976).
    • (1976) Acta Chir. Scand. (Suppl.) , vol.471 , pp. 1-74
    • Kjartansson, I.1
  • 29
    • 0025870664 scopus 로고
    • Factors in myocardial "perfusion" imaging with ultrafast MRI and Gd-DTPA administration
    • D. Burstein, E. Taratuta, W. J. Manning, Factors in myocardial "perfusion" imaging with ultrafast MRI and Gd-DTPA administration. Magn. Reson. Med. 20, 299-305 (1991).
    • (1991) Magn. Reson. Med. , vol.20 , pp. 299-305
    • Burstein, D.1    Taratuta, E.2    Manning, W.J.3
  • 32
    • 0027483587 scopus 로고
    • Contrast-enhanced first-pass myocardial perfusion imaging: Correlation between myocardial blood flow in dogs at rest and during hyperemia
    • N. Wilke, G. Simm, J. Zhang, J. Ellerman, X. Ya, H. Merkle, G. Path, H. Lüdemann, R. J. Bache, K. Uǧurbil, Contrast-enhanced first-pass myocardial perfusion imaging: correlation between myocardial blood flow in dogs at rest and during hyperemia. Magn. Reson. Med. 29, 485-497 (1993).
    • (1993) Magn. Reson. Med. , vol.29 , pp. 485-497
    • Wilke, N.1    Simm, G.2    Zhang, J.3    Ellerman, J.4    Ya, X.5    Merkle, H.6    Path, G.7    Lüdemann, H.8    Bache, R.J.9    Uǧurbil, K.10
  • 33
    • 0026482768 scopus 로고
    • Simultaneous MR acquisition of arterial and brain signal time curves
    • W. H. Perman, M. H. Gado, K. B. Larson, J. S. Perlmutter, Simultaneous MR acquisition of arterial and brain signal time curves. Magn. Reson. Med. 28, 74-83 (1992).
    • (1992) Magn. Reson. Med. , vol.28 , pp. 74-83
    • Perman, W.H.1    Gado, M.H.2    Larson, K.B.3    Perlmutter, J.S.4
  • 34
    • 0002629229 scopus 로고    scopus 로고
    • The value of gating and flow compensation for measurements of the arterial input function in dynamic susceptibility contrast MRI
    • H. Köstler, H. Becker, The value of gating and flow compensation for measurements of the arterial input function in dynamic susceptibility contrast MRI. Magn. Reson. Mater. Phys. Biol. Med. (Suppl.)4, 68 (1996).
    • (1996) Magn. Reson. Mater. Phys. Biol. Med. (Suppl.) , vol.4 , pp. 68
    • Köstler, H.1    Becker, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.