메뉴 건너뛰기




Volumn 14, Issue 2, 1998, Pages 76-82

A comparison of visual and computer-generated measures of 'seizure quality'

Author keywords

Dose; Electroconvulsive therapy; Postictal suppression; Regularity; Seizure adequacy

Indexed keywords

ADULT; AGED; ARTICLE; AUTOMATION; CLINICAL ARTICLE; COMPUTER; ELECTROCONVULSIVE THERAPY; ELECTROENCEPHALOGRAM; FEMALE; HUMAN; MALE; SEIZURE; STATISTICAL ANALYSIS;

EID: 0031807151     PISSN: 10950680     EISSN: None     Source Type: Journal    
DOI: 10.1097/00124509-199806000-00003     Document Type: Article
Times cited : (9)

References (15)
  • 1
    • 0013095811 scopus 로고
    • Unilateral electroconvulsive therapy
    • Fink M, Kety S, McGuagh J, eds. Washington, DC: Winston and Sons
    • D'Elia G. Unilateral electroconvulsive therapy. In: Fink M, Kety S, McGuagh J, eds. Psychobiology of convulsions therapy. Washington, DC: Winston and Sons, 1974.
    • (1974) Psychobiology of Convulsions Therapy
    • D'Elia, G.1
  • 2
    • 84965886444 scopus 로고
    • The equivalence of weighted kappa and the intraclass correlation coefficient as measures of reliability
    • Fleiss JL, Cohen J. The equivalence of weighted kappa and the intraclass correlation coefficient as measures of reliability. Educ Psychol Measurement 1973;33:613-9.
    • (1973) Educ Psychol Measurement , vol.33 , pp. 613-619
    • Fleiss, J.L.1    Cohen, J.2
  • 3
    • 0000147667 scopus 로고
    • Ten Twenty Electrode System
    • International Federation of Societies for Electroencephalography and Clinical Neurophysiology. Ten Twenty Electrode System. Electroencephalogr Clin Neurophysiol 1958;10:371-5.
    • (1958) Electroencephalogr Clin Neurophysiol , vol.10 , pp. 371-375
  • 4
    • 0027493495 scopus 로고
    • The effects of ECT stimulus dose and electrode placement on the ictal electroencephalogram: An intraindividual cross-over study
    • Krystal AD, Weiner RD, McCall WV, Shelp FE, Arias R, Smith P. The effects of ECT stimulus dose and electrode placement on the ictal electroencephalogram: an intraindividual cross-over study. Biol Psychiatry 1993;34:759-67.
    • (1993) Biol Psychiatry , vol.34 , pp. 759-767
    • Krystal, A.D.1    Weiner, R.D.2    McCall, W.V.3    Shelp, F.E.4    Arias, R.5    Smith, P.6
  • 6
    • 0029615501 scopus 로고
    • Can we teach psychiatric residents to rate seizure regularity?
    • McCall WV, Farah A, Reboussin D. Can we teach psychiatric residents to rate seizure regularity? Convulsive Ther 1995;4:248-52.
    • (1995) Convulsive Ther , vol.4 , pp. 248-252
    • McCall, W.V.1    Farah, A.2    Reboussin, D.3
  • 10
    • 0026351264 scopus 로고
    • Stimulus intensity, seizure threshold, and seizure duration: Impact on the efficacy and safety of electroconvulsive therapy
    • Sackeim HA, Devanand DP, Prudic J. Stimulus intensity, seizure threshold, and seizure duration: impact on the efficacy and safety of electroconvulsive therapy. Psychiatr Clin North Am 1991;14:803-43.
    • (1991) Psychiatr Clin North Am , vol.14 , pp. 803-843
    • Sackeim, H.A.1    Devanand, D.P.2    Prudic, J.3
  • 14
    • 0028292315 scopus 로고
    • Computer automated versus visually determined electroencephalographic and electromyographic seizure duration
    • Swarz CM, Abrams R, Rasmussen K, Pavel J, Zorumski CF, Srinivasaraghavan J. Computer automated versus visually determined electroencephalographic and electromyographic seizure duration. Convulsive Ther 1994;10:165-70.
    • (1994) Convulsive Ther , vol.10 , pp. 165-170
    • Swarz, C.M.1    Abrams, R.2    Rasmussen, K.3    Pavel, J.4    Zorumski, C.F.5    Srinivasaraghavan, J.6
  • 15
    • 0002631982 scopus 로고
    • EEG monitoring of ECT seizures
    • Coffey CE, ed. Washington, DC: American Psychiatric Press
    • Weiner RD, Krystal AD. EEG monitoring of ECT seizures. In: Coffey CE, ed. The clinical science of electroconvulsive therapy. Washington, DC: American Psychiatric Press, 1993:93-109.
    • (1993) The Clinical Science of Electroconvulsive Therapy , pp. 93-109
    • Weiner, R.D.1    Krystal, A.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.