메뉴 건너뛰기




Volumn 25, Issue 6, 1998, Pages 824-829

A simple algorithm for planar image registration in radiation therapy

Author keywords

Image registration; Portal images; Radiation therapy

Indexed keywords

GEOMETRY; IMAGE REGISTRATION; RADIOTHERAPY;

EID: 0031803362     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598292     Document Type: Article
Times cited : (13)

References (25)
  • 1
    • 0025191363 scopus 로고
    • A method for the measurement of field placement errors in digital portal images
    • H. Meertens, J. Bijhold, and J Strackee, "A method for the measurement of field placement errors in digital portal images," Phys. Med. Biol. 35, 299-323 (1990).
    • (1990) Phys. Med. Biol. , vol.35 , pp. 299-323
    • Meertens, H.1    Bijhold, J.2    Strackee, J.3
  • 2
    • 33744678620 scopus 로고
    • Computer aided error measurement for on-line portal imaging
    • W. C Lam, M. G. Herman, and K. S. Lam, "Computer aided error measurement for on-line portal imaging," Med. Phys. 17, 554 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 554
    • Lam, W.C.1    Herman, M.G.2    Lam, K.S.3
  • 3
    • 0026542468 scopus 로고
    • Optimization and evaluation of landmark-based image correlation
    • G. Ende, H. Treuer, and R. Boesecke, "Optimization and evaluation of landmark-based image correlation," Phys. Med. Biol 37, 261-271 (1992).
    • (1992) Phys. Med. Biol , vol.37 , pp. 261-271
    • Ende, G.1    Treuer, H.2    Boesecke, R.3
  • 4
    • 0027219182 scopus 로고
    • A ρ-θ technique for treatment verification in radiotherapy and its clinical applications
    • G. X. Ding, S. Shalev, and G. Gluchev, "A ρ-θ technique for treatment verification in radiotherapy and its clinical applications," Med. Phys. 20, 1135-1143 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1135-1143
    • Ding, G.X.1    Shalev, S.2    Gluchev, G.3
  • 5
    • 0027237480 scopus 로고
    • Automated determination of patient setup errors in radiation therapy using spherical radio-opaque markers
    • K. L. Lam, R K. Ten Haken, D. L. McShan, and A. F. Thornton, "Automated determination of patient setup errors in radiation therapy using spherical radio-opaque markers," Med. Phys. 20, 1145-1152 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1145-1152
    • Lam, K.L.1    Ten Haken, R.K.2    McShan, D.L.3    Thornton, A.F.4
  • 6
    • 0027183908 scopus 로고
    • Computer-assisted positioning of radiotherapy patients using implanted radiopaque fiducials
    • K. P. Gall and L. J. Verhey, "Computer-assisted positioning of radiotherapy patients using implanted radiopaque fiducials," Med. Phys. 20, 1153-1159 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1153-1159
    • Gall, K.P.1    Verhey, L.J.2
  • 7
    • 0027172788 scopus 로고
    • Three-dimensional verification of patient placement during radiotherapy using portal images
    • J. Bijhold, "Three-dimensional verification of patient placement during radiotherapy using portal images," Med. Phys. 20, 347-356 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 347-356
    • Bijhold, J.1
  • 9
    • 0027994323 scopus 로고
    • Unfolding patient motion with biplane radiographs
    • S. Li, C. A. Pelizzari, and G. T. Y. Chen, "Unfolding patient motion with biplane radiographs," Med Phys. 21, 1427-1433 (1994).
    • (1994) Med Phys. , vol.21 , pp. 1427-1433
    • Li, S.1    Pelizzari, C.A.2    Chen, G.T.Y.3
  • 10
    • 0025836884 scopus 로고
    • Investigation of an FFT-based correlation technique for verification of radiation treatment setup
    • S. M. Jones and A. L. Boyer, "Investigation of an FFT-based correlation technique for verification of radiation treatment setup," Med. Phys. 18, 1116-1127 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 1116-1127
    • Jones, S.M.1    Boyer, A.L.2
  • 11
    • 0028260271 scopus 로고
    • A semiautomatic method for registration of portal images
    • J. Moseley and P. Munro "A semiautomatic method for registration of portal images," Med. Phys. 21, 551-558 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 551-558
    • Moseley, J.1    Munro, P.2
  • 12
    • 0028243714 scopus 로고
    • Methods for fully automated verification of patient setup in external beam radiotherapy with polygon shaped fields
    • K. Eilertsen, A. Skkretting, and T. L. Tennvassas, "Methods for fully automated verification of patient setup in external beam radiotherapy with polygon shaped fields," Phys. Med. Biol. 39, 993-1012 (1994).
    • (1994) Phys. Med. Biol. , vol.39 , pp. 993-1012
    • Eilertsen, K.1    Skkretting, A.2    Tennvassas, T.L.3
  • 13
    • 0028236004 scopus 로고
    • Pseudocorrelation: A fast, robust, absolute, grey-level image alignment algorithm
    • T. Radcliffe, R. Rajapakshe, and S. Shaley, "Pseudocorrelation: a fast, robust, absolute, grey-level image alignment algorithm," Med. Phys. 21, 761-769 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 761-769
    • Radcliffe, T.1    Rajapakshe, R.2    Shaley, S.3
  • 14
    • 0029914477 scopus 로고    scopus 로고
    • A portal image alignment and patient setup verification procedure using moments and correlation techniques
    • L. Dong and A. Boyer, "A portal image alignment and patient setup verification procedure using moments and correlation techniques," Phys. Med. Biol. 41, 697-723 (1996)
    • (1996) Phys. Med. Biol. , vol.41 , pp. 697-723
    • Dong, L.1    Boyer, A.2
  • 15
    • 0029996767 scopus 로고    scopus 로고
    • Investigation of a phase-only correlation technique for anatomical alignment of portal images in radiation therapy
    • J. Wang, L. E. Reinstein, J. Hanley, and A. G. Meek, "Investigation of a phase-only correlation technique for anatomical alignment of portal images in radiation therapy," Phys. Med. Biol. 41, 1045-1058 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1045-1058
    • Wang, J.1    Reinstein, L.E.2    Hanley, J.3    Meek, A.G.4
  • 16
    • 0027278542 scopus 로고
    • Automatic on-line inspection of patient setup in radiation therapy using digital portal images
    • K. G. A. Gilhuijs and M. van Herk, "Automatic on-line inspection of patient setup in radiation therapy using digital portal images," Med. Phys. 20, 667-677 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 667-677
    • Gilhuijs, K.G.A.1    Van Herk, M.2
  • 18
    • 0026652740 scopus 로고
    • Correlation of projection radiographs in radiation therapy using open curve segments and points
    • J M. Balter, C. A. Pelizzari, and G. T. Y Chen, "Correlation of projection radiographs in radiation therapy using open curve segments and points," Med. Phys. 19, 329-334 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 329-334
    • Balter, J.M.1    Pelizzari, C.A.2    Chen, G.T.Y.3
  • 19
    • 0030456927 scopus 로고    scopus 로고
    • Alignment of multi-segmented anatomical features from radiation therapy images by using least square fitting
    • J. Cai, S. Zhou, J. Hopkinson, V. A. Saxena, and J. Chu, "Alignment of multi-segmented anatomical features from radiation therapy images by using least square fitting," Med. Phys. 23, 2069-2075 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 2069-2075
    • Cai, J.1    Zhou, S.2    Hopkinson, J.3    Saxena, V.A.4    Chu, J.5
  • 20
    • 0001008029 scopus 로고
    • An efficient method for finding the minimum of a function of several variables without calculating derivatives
    • M. J. D. Powell, "An efficient method for finding the minimum of a function of several variables without calculating derivatives," Comput J. 7, 155-163 (1964).
    • (1964) Comput J. , vol.7 , pp. 155-163
    • Powell, M.J.D.1
  • 24
    • 0024104158 scopus 로고
    • Hierarchical chamfer matching: A parametric edge matching algorithm
    • G. Borgefors, "Hierarchical chamfer matching: A parametric edge matching algorithm," IEEE Trans. Pattern Analysis Machine Intelligence, PAMI-10, 849-865 (1988)
    • (1988) IEEE Trans. Pattern Analysis Machine Intelligence , vol.PAMI-10 , pp. 849-865
    • Borgefors, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.