메뉴 건너뛰기




Volumn 7, Issue 3, 1998, Pages 250-254

Aortic valve replacement with stentless porcine aortic valves: A ten- year experience

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA VALVE REGURGITATION; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; ARTICLE; BACTERIAL ENDOCARDITIS; CLINICAL ARTICLE; CONTROLLED STUDY; DOPPLER ECHOCARDIOGRAPHY; FEMALE; FOLLOW UP; HEART LEFT VENTRICLE HYPERTROPHY; HEMODYNAMICS; HUMAN; MALE; PRIORITY JOURNAL; STENT; STROKE; SURGICAL MORTALITY; SURVIVAL RATE; SWINE; TRANSIENT ISCHEMIC ATTACK; TREATMENT OUTCOME;

EID: 0031803044     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (84)

References (15)
  • 2
    • 0014777211 scopus 로고
    • Heterograft valves: An analysis of clinical results of valve replacement
    • O'Brien MF, Neilson GH, Galea EG, et al. Heterograft valves: An analysis of clinical results of valve replacement. Circulation 1970;16(suppl.II):II-16-II19
    • (1970) Circulation , vol.16 , Issue.2 SUPPL.
    • O'Brien, M.F.1    Neilson, G.H.2    Galea, E.G.3
  • 3
    • 0024237524 scopus 로고
    • Aortic valve replacement with stentless porcine bioprostheses
    • David TE, Ropchan GC, Butany JW. Aortic valve replacement with stentless porcine bioprostheses. J Cardiac Surg 1988;3:501-505
    • (1988) J Cardiac Surg , vol.3 , pp. 501-505
    • David, T.E.1    Ropchan, G.C.2    Butany, J.W.3
  • 4
    • 0025191277 scopus 로고
    • Aortic valve replacement with stentless porcine bioprosthesis
    • David TE, Pollick C, Bos J. Aortic valve replacement with stentless porcine bioprosthesis. J Thorac Cardiovasc Surg 1990;99:113-118
    • (1990) J Thorac Cardiovasc Surg , vol.99 , pp. 113-118
    • David, T.E.1    Pollick, C.2    Bos, J.3
  • 8
    • 0027942269 scopus 로고
    • Hemodynamic assessment of the stentless Toronto SPV bioprosthesis by echocardiography
    • Walther T, Falk V, Austshback R, et al. Hemodynamic assessment of the stentless Toronto SPV bioprosthesis by echocardiography. J Heart Valve Dis 1994;3:657-665
    • (1994) J Heart Valve Dis , vol.3 , pp. 657-665
    • Walther, T.1    Falk, V.2    Austshback, R.3
  • 9
    • 0029093740 scopus 로고
    • Perioperative assessment of aortic homograft, Toronto stentless valve, and stented bioprosthesis in the aortic position
    • Jin XY, Gibson DG, Yacoub M, Pepper JR. Perioperative assessment of aortic homograft, Toronto stentless valve, and stented bioprosthesis in the aortic position. Ann Thorac Surg 1995;60:S395-S401
    • (1995) Ann Thorac Surg , vol.60
    • Jin, X.Y.1    Gibson, D.G.2    Yacoub, M.3    Pepper, J.R.4
  • 10
    • 0029016342 scopus 로고
    • The Toronto SPV bioprosthesis: One-year results in 100 patients
    • Mohr FW, Walther T, Baryales M, et al. The Toronto SPV bioprosthesis: One-year results in 100 patients. Ann Thorac Surg 1995;60:171-175
    • (1995) Ann Thorac Surg , vol.60 , pp. 171-175
    • Mohr, F.W.1    Walther, T.2    Baryales, M.3
  • 13
    • 0026476513 scopus 로고
    • Clinical and hemodynamic assessment of the Hancock II bioprosthesis
    • David TE, Armstrong S, Sun Z. Clinical and hemodynamic assessment of the Hancock II bioprosthesis. Ann Thorac Surg 1992;54:661-668
    • (1992) Ann Thorac Surg , vol.54 , pp. 661-668
    • David, T.E.1    Armstrong, S.2    Sun, Z.3
  • 14
    • 0029154846 scopus 로고
    • The Carpentier-Edwards pericardial aortic valve. Ten-year results
    • Cosgrove DM, Lytle BW, Taylor PC, et al. The Carpentier-Edwards pericardial aortic valve. Ten-year results. J Thorac Cardiovasc Surg 1995;110:651-662
    • (1995) J Thorac Cardiovasc Surg , vol.110 , pp. 651-662
    • Cosgrove, D.M.1    Lytle, B.W.2    Taylor, P.C.3
  • 15
    • 0029189741 scopus 로고
    • An anatomic and physiologic approach to acquired heart disease
    • David TE. An anatomic and physiologic approach to acquired heart disease. Eur J Cardiothorac Surg 1995;9:175-180
    • (1995) Eur J Cardiothorac Surg , vol.9 , pp. 175-180
    • David, T.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.