Conversion of cardiac and liver transplant recipients from HPLC and FPIA (polyclonal) to an FPIA (monoclonal) technique for measurement of blood cyclosporin A

Author keywords

Fluorescence polarization immunoassay; Immunosuppressive drugs; Intermethod comparison; Therapeutic drug monitoring; Transplantation

Indexed keywords

CYCLOSPORIN A; MONOCLONAL ANTIBODY; POLYCLONAL ANTIBODY;

EID: 0031796298     PISSN: 08878013     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1098-2825(1998)12:6<337::AID-JCLA2>3.0.CO;2-D     Document Type: Article
Times cited : (4)

References (16)
  • 1
    • 0023232859 scopus 로고
    • Critical issues in cyclosporine monitoring: Report of the task force on cyclosporine monitoring
    • Shaw LM, Bowers L, Demers L, et al.: Critical issues in cyclosporine monitoring: Report of the task force on cyclosporine monitoring [Special Report]. Clin Chem 33:1269-1288, 1987
    • (1987) Clin Chem , vol.33 , pp. 1269-1288
    • Shaw, L.M.1    Bowers, L.2    Demers, L.3
  • 2
    • 0023508097 scopus 로고
    • Cyclosporine: Structure, pharmacokinetics, and therapeutic drug monitoring
    • Vine W, Bowers LD: Cyclosporine: Structure, pharmacokinetics, and therapeutic drug monitoring. Crit Rev Clin Lab Sci 25:275-311, 1987.
    • (1987) Crit Rev Clin Lab Sci , vol.25 , pp. 275-311
    • Vine, W.1    Bowers, L.D.2
  • 4
    • 0027156733 scopus 로고
    • Morphology of ischemic acute renal failure, normal function and cyclosporine toxicity in cyclosporine-treated renal allograft recipients
    • Solez K, Rocusen LC, Marcussen N, et al.: Morphology of ischemic acute renal failure, normal function and cyclosporine toxicity in cyclosporine-treated renal allograft recipients. Kidney Int 43:1058-1067, 1993
    • (1993) Kidney Int , vol.43 , pp. 1058-1067
    • Solez, K.1    Rocusen, L.C.2    Marcussen, N.3
  • 5
    • 0028863807 scopus 로고
    • Alternative CsA metabolic pathways and toxicity
    • Christians U, Sewing KF: Alternative CsA metabolic pathways and toxicity. Clin Biochem 28:547-59, 1995.
    • (1995) Clin Biochem , vol.28 , pp. 547-559
    • Christians, U.1    Sewing, K.F.2
  • 6
    • 0025997099 scopus 로고
    • Cyclosporine metabolite pattern in blood and urine of liver graft recipient: Association of cyclosporine metabolites with nephrotoxicity
    • Christians U, Kolhaw R, Budniak J, et al.: Cyclosporine metabolite pattern in blood and urine of liver graft recipient: Association of cyclosporine metabolites with nephrotoxicity. Eur J Clin Pharmacol 41:285-290, 1991.
    • (1991) Eur J Clin Pharmacol , vol.41 , pp. 285-290
    • Christians, U.1    Kolhaw, R.2    Budniak, J.3
  • 7
    • 0028824489 scopus 로고
    • Lake Louise Conference on CsA monitoring in organ transplantation: Report of the consensus panel
    • Oellerich M, Armstrong VM, Kahan B, et al.: Lake Louise Conference on CsA monitoring in organ transplantation: Report of the consensus panel. Ther Drug Monit 17:642-654, 1995.
    • (1995) Ther Drug Monit , vol.17 , pp. 642-654
    • Oellerich, M.1    Armstrong, V.M.2    Kahan, B.3
  • 8
    • 0026447540 scopus 로고
    • Measurement of cyclosporine by liquid chromatography and three immunoassays in blood from liver, cardiac, and renal transplant recipients
    • McBride JH, Kim SS, Rodgerson DO, Reyes AF, Ota MK: Measurement of cyclosporine by liquid chromatography and three immunoassays in blood from liver, cardiac, and renal transplant recipients. Clin Chem 38:2300-2306, 1992.
    • (1992) Clin Chem , vol.38 , pp. 2300-2306
    • McBride, J.H.1    Kim, S.S.2    Rodgerson, D.O.3    Reyes, A.F.4    Ota, M.K.5
  • 9
    • 0023488849 scopus 로고
    • Automated solid-phase extraction and liquid chromatography for assay of cyclosporine in whole blood
    • Kabra PM, Wall JH, Dimson P: Automated solid-phase extraction and liquid chromatography for assay of cyclosporine in whole blood. Clin Chem 33:2272-2274, 1987.
    • (1987) Clin Chem , vol.33 , pp. 2272-2274
    • Kabra, P.M.1    Wall, J.H.2    Dimson, P.3
  • 10
    • 0013525020 scopus 로고
    • Evaluation of the new cyclosporine monoclonal antibody fluorescent polarization immunoassay in cardiac and renal transplants
    • Schroeder T, Vine W, Ruckrigl D, Pesce A, Bhat G, First R: Evaluation of the new cyclosporine monoclonal antibody fluorescent polarization immunoassay in cardiac and renal transplants [Abstract]. Clin Chem 37:990, 1991.
    • (1991) Clin Chem , vol.37 , pp. 990
    • Schroeder, T.1    Vine, W.2    Ruckrigl, D.3    Pesce, A.4    Bhat, G.5    First, R.6
  • 11
    • 0029817346 scopus 로고    scopus 로고
    • Toxic effects of immunosuppressive drugs: Mechanisms and strategies for controlling them
    • Shaw LM, Kaplan B, Kaufman D: Toxic effects of immunosuppressive drugs: Mechanisms and strategies for controlling them. Clin Chem 42:1316-1321, 1996
    • (1996) Clin Chem , vol.42 , pp. 1316-1321
    • Shaw, L.M.1    Kaplan, B.2    Kaufman, D.3
  • 12
    • 0025308872 scopus 로고
    • A monoclonal antibody fluorescent polarization immunoassay for cyclosporine
    • Wang P, Meucci V, Simpson E, et al.: A monoclonal antibody fluorescent polarization immunoassay for cyclosporine. Transplant Proc 22:1186-1188, 1990.
    • (1990) Transplant Proc , vol.22 , pp. 1186-1188
    • Wang, P.1    Meucci, V.2    Simpson, E.3
  • 13
    • 0019412879 scopus 로고
    • Fluorescence polarization immunoassay III: An automated system for therapeutic drug determinations
    • Jolley ME, Stroupe SD, Schwenzer KS, et al.: Fluorescence polarization immunoassay III: an automated system for therapeutic drug determinations. Clin Chem 27:1575-1579, 1981.
    • (1981) Clin Chem , vol.27 , pp. 1575-1579
    • Jolley, M.E.1    Stroupe, S.D.2    Schwenzer, K.S.3
  • 14
    • 0024365391 scopus 로고
    • Measurement of cyclosporine in plasma from patients with various transplants: HPLC and radioimmunoassay with a specific monoclonal antibody compared
    • McBride JH, Rodgerson DO, Park SS, Reyes AF: Measurement of cyclosporine in plasma from patients with various transplants: HPLC and radioimmunoassay with a specific monoclonal antibody compared. Clin Chem 35:1726-1730, 1989.
    • (1989) Clin Chem , vol.35 , pp. 1726-1730
    • McBride, J.H.1    Rodgerson, D.O.2    Park, S.S.3    Reyes, A.F.4
  • 15
    • 0024476756 scopus 로고
    • Calibration of 1251 immunoassay measuring cyclosporin A
    • Krepil J, McPhillips M: Calibration of 1251 immunoassay measuring cyclosporin A Clin Chem 35:181-182, 1989.
    • (1989) Clin Chem , vol.35 , pp. 181-182
    • Krepil, J.1    McPhillips, M.2
  • 16
    • 0028812790 scopus 로고
    • Analytic requirements for immunosuppressive drugs in clinical trials
    • Shaw LM, Annesley TM, Kaplan B, Brayman K: Analytic requirements for immunosuppressive drugs in clinical trials. Ther Drug Monit 17:577-583, 1995.
    • (1995) Ther Drug Monit , vol.17 , pp. 577-583
    • Shaw, L.M.1    Annesley, T.M.2    Kaplan, B.3    Brayman, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.