메뉴 건너뛰기




Volumn 78, Issue 11, 1998, Pages 1166-1174

Reliability of phase-velocity measurements of tibial bone

Author keywords

Bending stiffness; Bone; Flexural waves; Measurement; Reliability; Spinal cord injury

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; DEVICE; FEMALE; HUMAN; MALE; MEASUREMENT; RELIABILITY; REPRODUCIBILITY; RIGIDITY; SPINAL CORD INJURY; TIBIA;

EID: 0031792074     PISSN: 00319023     EISSN: None     Source Type: Journal    
DOI: 10.1093/ptj/78.11.1166     Document Type: Article
Times cited : (22)

References (21)
  • 1
    • 0029942211 scopus 로고    scopus 로고
    • Practical guide for the use of bone mineral measurements in the assessment of treatment of osteoporosis: A position paper of the European Foundation for Osteoporosis and Bone Disease
    • Kanis JA, Devogelaer JP, Gennari C. Practical guide for the use of bone mineral measurements in the assessment of treatment of osteoporosis: a position paper of the European Foundation for Osteoporosis and Bone Disease. Osteoporos Int. 1996;6:256-261.
    • (1996) Osteoporos Int , vol.6 , pp. 256-261
    • Kanis, J.A.1    Devogelaer, J.P.2    Gennari, C.3
  • 2
    • 0027222768 scopus 로고
    • Consensus Development Conference report: Diagnosis, prophylaxis, and treatment of osteoporosis
    • Consensus Development Conference report: diagnosis, prophylaxis, and treatment of osteoporosis. Am J Med. 1993;94:646-650.
    • (1993) Am J Med , vol.94 , pp. 646-650
  • 5
    • 0028503542 scopus 로고
    • Entwicklung und anpassung der biegesteifigkeit des extremitätenskelettes durch training am beispiel der tibia
    • Stüssi E, Bischof HJ, Lucchinetti E, et al. Entwicklung und anpassung der biegesteifigkeit des extremitätenskelettes durch training am beispiel der tibia. Sportverletz Sportschaden. 1994;8:103-110.
    • (1994) Sportverletz Sportschaden , vol.8 , pp. 103-110
    • Stüssi, E.1    Bischof, H.J.2    Lucchinetti, E.3
  • 6
    • 0343447016 scopus 로고    scopus 로고
    • The flight of a bone stiffness measurement device on EUROMIR 95 and future applications
    • Stüssi E, Lawson R. The flight of a bone stiffness measurement device on EUROMIR 95 and future applications. Microgravity News. 1996;9(1);1-4.
    • (1996) Microgravity News , vol.9 , Issue.1 , pp. 1-4
    • Stüssi, E.1    Lawson, R.2
  • 7
    • 85038548633 scopus 로고    scopus 로고
    • Adaptation of tibia stiffness to low-gravity conditions (preliminary EUROMIR 95 report)
    • June 16-20, Trondheim, Norway
    • Stüssi E, Herzog R, Lawson R. Adaptation of tibia stiffness to low-gravity conditions (preliminary EUROMIR 95 report). Presented as an abstract at: Sixth European Symposium on Life Sciences Research in Space; June 16-20, 1996; Trondheim, Norway.
    • (1996) Sixth European Symposium on Life Sciences Research in Space
    • Stüssi, E.1    Herzog, R.2    Lawson, R.3
  • 8
    • 0001908650 scopus 로고
    • Measurement and clinical practice
    • Rothstein JM, ed. New York, NY: Churchill Livingstone Inc
    • Rothstein JM. Measurement and clinical practice. In: Rothstein JM, ed. Measurement in Physical Therapy. New York, NY: Churchill Livingstone Inc; 1985:1-46.
    • (1985) Measurement in Physical Therapy , pp. 1-46
    • Rothstein, J.M.1
  • 9
    • 0024651576 scopus 로고
    • Reliability: Consistency or differentiating among subjects?
    • Letter to the editor
    • Stratford PW. Reliability: consistency or differentiating among subjects? Phys Ther. 1989;69:299-300. Letter to the editor.
    • (1989) Phys Ther , vol.69 , pp. 299-300
    • Stratford, P.W.1
  • 10
    • 0027155544 scopus 로고
    • The application of generalizability theory to reliability assessment: An illustration using isometric force measurements
    • Roebroeck ME, Harlaar J, Lankhorst GJ. The application of generalizability theory to reliability assessment: an illustration using isometric force measurements. Phys Ther. 1993;73:386-395.
    • (1993) Phys Ther , vol.73 , pp. 386-395
    • Roebroeck, M.E.1    Harlaar, J.2    Lankhorst, G.J.3
  • 15
    • 0024043387 scopus 로고
    • Assessment of bone mineral content by in vivo measurement of flexural wave velocities
    • Stüssi E, Fäh D. Assessment of bone mineral content by in vivo measurement of flexural wave velocities. Med Biol Eng Comput. 1988; 26:349-354.
    • (1988) Med Biol Eng Comput , vol.26 , pp. 349-354
    • Stüssi, E.1    Fäh, D.2
  • 16
    • 0024238754 scopus 로고
    • Phase velocity measurement of flexural waves in human tibia
    • Fäh D, Stüssi E. Phase velocity measurement of flexural waves in human tibia. J Biomech. 1988;21:975-983.
    • (1988) J Biomech , vol.21 , pp. 975-983
    • Fäh, D.1    Stüssi, E.2
  • 18
    • 84987300572 scopus 로고
    • Considerations in the choice of interobserver reliability estimates
    • Hartmann DP. Considerations in the choice of interobserver reliability estimates. J Appl Behav Anal. 1977;10:103-116.
    • (1977) J Appl Behav Anal , vol.10 , pp. 103-116
    • Hartmann, D.P.1
  • 21
    • 0027220052 scopus 로고
    • Clinical determination of bone quality: Is ultrasound an answer?
    • Brandenburger GH. Clinical determination of bone quality: Is ultrasound an answer? Calcif Tissue Int. 1993;53(suppl 1):S151-S156.
    • (1993) Calcif Tissue Int , vol.53 , Issue.1 SUPPL.
    • Brandenburger, G.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.