메뉴 건너뛰기




Volumn 9, Issue 4, 1998, Pages 80-84

Traditional versus thermal techniques of arthroscopic stabilization

Author keywords

[No Author keywords available]

Indexed keywords

ABSORBABLE SUTURE;

EID: 0031791561     PISSN: 10419918     EISSN: None     Source Type: Journal    
DOI: 10.1097/00001433-199808000-00014     Document Type: Review
Times cited : (6)

References (37)
  • 1
    • 0027472587 scopus 로고
    • Arthroscopic shoulder capsulorrhaphy using metal staples
    • Detrisac DA, Johnson LL: Arthroscopic shoulder capsulorrhaphy using metal staples. Orthop Clin North Am 1993, 24:71-88.
    • (1993) Orthop Clin North Am , vol.24 , pp. 71-88
    • Detrisac, D.A.1    Johnson, L.L.2
  • 2
    • 0023180571 scopus 로고
    • Arthroscopic Bankart suture repair: Technique and early results
    • Morgan CD, Bodenstab AB: Arthroscopic Bankart suture repair: technique and early results. Arthroscopy 1987, 3:111-122.
    • (1987) Arthroscopy , vol.3 , pp. 111-122
    • Morgan, C.D.1    Bodenstab, A.B.2
  • 3
    • 0000431306 scopus 로고
    • Arthroscopic transglenoid suture repair
    • Morgan CD: Arthroscopic transglenoid suture repair. Oper Tech Orthop 1991, 1:171-179.
    • (1991) Oper Tech Orthop , vol.1 , pp. 171-179
    • Morgan, C.D.1
  • 4
    • 0023908047 scopus 로고
    • Arthroscopic reconstruction for anterior shoulder instability
    • Caspari RB: Arthroscopic reconstruction for anterior shoulder instability. Tech Orthop 1988, 3:59-66.
    • (1988) Tech Orthop , vol.3 , pp. 59-66
    • Caspari, R.B.1
  • 5
    • 0000339176 scopus 로고
    • Arthroscopic Bankart repair using a cannulated, absorbable, fixation device
    • Warner JP, Warren RF: Arthroscopic Bankart repair using a cannulated, absorbable, fixation device. Oper Tech Orthop Surg 1991, 1:192-198.
    • (1991) Oper Tech Orthop Surg , vol.1 , pp. 192-198
    • Warner, J.P.1    Warren, R.F.2
  • 6
    • 0030455834 scopus 로고    scopus 로고
    • An arthroscopic technique for anterior stabilization of the shoulder with a bioabsorbable tack
    • Speer KP, Warren RF, Pagnani M, Warner JJP: An arthroscopic technique for anterior stabilization of the shoulder with a bioabsorbable tack. J Bone Joint Surg Am 1996, 78:1801-1807.
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 1801-1807
    • Speer, K.P.1    Warren, R.F.2    Pagnani, M.3    Warner, J.J.P.4
  • 7
    • 13144277795 scopus 로고
    • Arthroscopic Bankart repair using suture anchors
    • Wolf EM, Wilk RM, Richmond JC: Arthroscopic Bankart repair using suture anchors. Oper Tech Orthop 1991, 1:184-191.
    • (1991) Oper Tech Orthop , vol.1 , pp. 184-191
    • Wolf, E.M.1    Wilk, R.M.2    Richmond, J.C.3
  • 8
    • 0030664284 scopus 로고    scopus 로고
    • Two- To five-year followup of arthroscopic Bankart reconstruction using a suture anchor technique
    • Koss S, Richmond JC, Woodward JS, Jr: Two-to five-year followup of arthroscopic Bankart reconstruction using a suture anchor technique. Am J Sports Med 1997, 25:809-812. Twenty-seven patients were retrospectively reviewed and 30% failed arthroscopic stabilization. The authors have dramatically narrowed their indications for this procedure.
    • (1997) Am J Sports Med , vol.25 , pp. 809-812
    • Koss, S.1    Richmond, J.C.2    Woodward Jr., J.S.3
  • 9
    • 0031055904 scopus 로고    scopus 로고
    • Arthroscopic Bankart repair in a high demand patient population
    • Bacilla P, Field LD, Savoie FH III: Arthroscopic Bankart repair in a high demand patient population. Arthroscopy 1997, 13:51-60. This is the best report to date following arthroscopic suture anchor repair. Ninety-three percent of patients had excellent results and 90% were able to return to their sport. Caution is necessary, however, due to the short-term follow-up of only 30 months (range, 18-36 months).
    • (1997) Arthroscopy , vol.13 , pp. 51-60
    • Bacilla, P.1    Field, L.D.2    Savoie III, F.H.3
  • 10
    • 0028033399 scopus 로고
    • Use of the suture anchor in Bankart reconstruction: A follow-up report
    • Levine WN, Donaldson WR, Richmond JC: Use of the suture anchor in Bankart reconstruction: a follow-up report. Am J Sports Med 1994, 22:723-726.
    • (1994) Am J Sports Med , vol.22 , pp. 723-726
    • Levine, W.N.1    Donaldson, W.R.2    Richmond, J.C.3
  • 11
    • 0030697274 scopus 로고    scopus 로고
    • Assessment of failed arthroscopic anterior labral repairs: Findings at open surgery
    • Mologne TS, McBride MT, Lapoint JM: Assessment of failed arthroscopic anterior labral repairs: findings at open surgery. Am J Sports Med 1997, 25:813-817.
    • (1997) Am J Sports Med , vol.25 , pp. 813-817
    • Mologne, T.S.1    McBride, M.T.2    Lapoint, J.M.3
  • 12
    • 0030886646 scopus 로고    scopus 로고
    • Arthroscopic transglenoid suture capsulolabral repair: Five-year followup
    • Manta JP, Organ S, Nirschl RP, Pettrone FA: Arthroscopic transglenoid suture capsulolabral repair: five-year followup. Am J Sports Med 1997, 25:614-618. Only 40% of patients had stability at a minimum follow-up of 5 years in this group of patients that had had 90% stability in their preliminary results.
    • (1997) Am J Sports Med , vol.25 , pp. 614-618
    • Manta, J.P.1    Organ, S.2    Nirschl, R.P.3    Pettrone, F.A.4
  • 14
    • 0030934378 scopus 로고    scopus 로고
    • Results of arthroscopic versus open Bankart suture repair
    • Geiger DF, Hurley JA, Tovey JA, Rao JP: Results of arthroscopic versus open Bankart suture repair. Clin Orthop 1997, 337:111-117. One of the few published direct comparison reports showing a clear advantage of the open procedure.
    • (1997) Clin Orthop , vol.337 , pp. 111-117
    • Geiger, D.F.1    Hurley, J.A.2    Tovey, J.A.3    Rao, J.P.4
  • 15
    • 0027185106 scopus 로고
    • Arthroscopic versus open Bankart procedures: A comparison of early morbidity and complications
    • Green MR, Christensen KP: Arthroscopic versus open Bankart procedures: a comparison of early morbidity and complications. Arthroscopy 1993, 9:371-374.
    • (1993) Arthroscopy , vol.9 , pp. 371-374
    • Green, M.R.1    Christensen, K.P.2
  • 16
    • 0029879385 scopus 로고    scopus 로고
    • Arthroscopic versus open reconstruction of the shoulder in patients with isolated Bankart lesions
    • Guanche CA, Quick DC, Sodergren KM, Buss DD: Arthroscopic versus open reconstruction of the shoulder in patients with isolated Bankart lesions. Am J Sports Med 1996, 24:144-148.
    • (1996) Am J Sports Med , vol.24 , pp. 144-148
    • Guanche, C.A.1    Quick, D.C.2    Sodergren, K.M.3    Buss, D.D.4
  • 17
    • 0031181683 scopus 로고    scopus 로고
    • Arthroscopic repair of glenolabral injuries with an absorbable fixation device
    • Segmuller HE, Hayes MG, Saies AD: Arthroscopic repair of glenolabral injuries with an absorbable fixation device. J Shoulder Elbow Surg 1997, 6:383-392.
    • (1997) J Shoulder Elbow Surg , vol.6 , pp. 383-392
    • Segmuller, H.E.1    Hayes, M.G.2    Saies, A.D.3
  • 18
    • 0028050379 scopus 로고
    • Arthroscopic Bankart repair versus nonoperative treatment for acute, initial anterior shoulder dislocations
    • Arciero RA, Wheeler JH, Ryan JB, McBride JT: Arthroscopic Bankart repair versus nonoperative treatment for acute, initial anterior shoulder dislocations. Am J Sports Med 1994, 22:589-594.
    • (1994) Am J Sports Med , vol.22 , pp. 589-594
    • Arciero, R.A.1    Wheeler, J.H.2    Ryan, J.B.3    McBride, J.T.4
  • 19
    • 0029156941 scopus 로고
    • Arthroscopic bioabsorbable tack stabilization of initial anterior shoulder dislocations: A preliminary report
    • Arciero RA, Taylor DC, Snyder RJ, Uhorchak JM: Arthroscopic bioabsorbable tack stabilization of initial anterior shoulder dislocations: a preliminary report. Arthroscopy 1995, 11:410-417.
    • (1995) Arthroscopy , vol.11 , pp. 410-417
    • Arciero, R.A.1    Taylor, D.C.2    Snyder, R.J.3    Uhorchak, J.M.4
  • 20
    • 0030819546 scopus 로고    scopus 로고
    • Arthroscopic transglenoid multiple suture repair: 2 to 8 year results in 150 shoulders
    • Torchia ME, Caspari RB, Asselmeier MA, Beach WR, Gayari M: Arthroscopic transglenoid multiple suture repair: 2 to 8 year results in 150 shoulders. Arthroscopy 1997, 13:609-619. This is the longest follow-up of this technique reported by one of the pioneers. Unfortunately, only 31 patients were available for physical examination. The results were inferior in younger age groups (< age 16) and with longer follow-up (>2 years). This emphasizes the need for long term follow-up of these types of procedures.
    • (1997) Arthroscopy , vol.13 , pp. 609-619
    • Torchia, M.E.1    Caspari, R.B.2    Asselmeier, M.A.3    Beach, W.R.4    Gayari, M.5
  • 21
    • 0030953993 scopus 로고    scopus 로고
    • Arthroscopic reconstruction of traumatic anterior instability of the shoulder: The Caspari technique
    • Savoie FH III, Miller CD, Field LD: Arthroscopic reconstruction of traumatic anterior instability of the shoulder: the Caspari technique. Arthroscopy 1997, 13:201-209. This is the best report to date on the arthroscopic transglenoid suture technique. The authors reviewed the unacceptably high recurrence rate in the literature and identified contributing factors in many of the studies, including insufficient release of labral-ligamentous tissue, too few sutures, and young age of patients.
    • (1997) Arthroscopy , vol.13 , pp. 201-209
    • Savoie III, F.H.1    Miller, C.D.2    Field, L.D.3
  • 22
    • 0031960502 scopus 로고    scopus 로고
    • Arthroscopic Bankart suture repair for traumatic anterior shoulder instability: Analysis of the causes of recurrence
    • Hayashida K, Minoru Y, Nakagawa S, Okamura K, Fukushima S: Arthroscopic Bankart suture repair for traumatic anterior shoulder instability: analysis of the causes of recurrence. Arthroscopy 1998, 14:295-301.
    • (1998) Arthroscopy , vol.14 , pp. 295-301
    • Hayashida, K.1    Minoru, Y.2    Nakagawa, S.3    Okamura, K.4    Fukushima, S.5
  • 23
    • 0031969217 scopus 로고    scopus 로고
    • Arthroscopic stabilization of the shoulder for acute primary dislocations using a transglenoid suture technique
    • Salmon JM, Bell SN: Arthroscopic stabilization of the shoulder for acute primary dislocations using a transglenoid suture technique. Arthroscopy 1998, 14:143-147.
    • (1998) Arthroscopy , vol.14 , pp. 143-147
    • Salmon, J.M.1    Bell, S.N.2
  • 24
    • 0030795128 scopus 로고    scopus 로고
    • The arthroscopic treatment of posterior shoulder instability: Two-year results of a multiple suture technique
    • McIntyre LF, Caspari RB, Savoie FH III: The arthroscopic treatment of posterior shoulder instability: two-year results of a multiple suture technique. Arthroscopy 1997, 13:426-432,
    • (1997) Arthroscopy , vol.13 , pp. 426-432
    • McIntyre, L.F.1    Caspari, R.B.2    Savoie III, F.H.3
  • 25
    • 0031965911 scopus 로고    scopus 로고
    • Arthroscopic capsular plication for posterior shoulder instability
    • Wolf EM, Eakin CL: Arthroscopic capsular plication for posterior shoulder instability. Arthroscopy 1998, 14:153-163.
    • (1998) Arthroscopy , vol.14 , pp. 153-163
    • Wolf, E.M.1    Eakin, C.L.2
  • 26
    • 0030861307 scopus 로고    scopus 로고
    • The arthroscopic treatment of multidirectional shoulder instability: Two-year results of a multiple suture technique
    • McIntyre LF, Caspari RB, Savoie FH III, The arthroscopic treatment of multidirectional shoulder instability: two-year results of a multiple suture technique, Arthroscopy 1997, 13:418-425.
    • (1997) Arthroscopy , vol.13 , pp. 418-425
    • McIntyre, L.F.1    Caspari, R.B.2    Savoie III, F.H.3
  • 27
    • 0030886317 scopus 로고    scopus 로고
    • The thermal properties of bovine joint capsule: The basic science of laser- and radiofrequency-induced capsular shrinkage
    • Naseef GS III, Foster TE, Trauner K, Solhpour S, Anderson RR, Zarins B: the thermal properties of bovine joint capsule: the basic science of laser- and radiofrequency-induced capsular shrinkage. Am J Sports Med 1997, 25:670-674. The authors show that thermal energy of 65°C causes significant shrinkage of bovine joint capsule.
    • (1997) Am J Sports Med , vol.25 , pp. 670-674
    • Naseef III, G.S.1    Foster, T.E.2    Trauner, K.3    Solhpour, S.4    Anderson, R.R.5    Zarins, B.6
  • 28
    • 0030725931 scopus 로고    scopus 로고
    • Tissue shrinkage with the holmiumtyttrium aluminum garnet laser: A postoperative assessment of tissue length, stiffness, and structure
    • Schaefer SL, Ciarelli MJ, Arnoczky SP, Ross HE: Tissue shrinkage with the holmiumtyttrium aluminum garnet laser: a postoperative assessment of tissue length, stiffness, and structure. Am J Sports Med 1997, 25:841-848.
    • (1997) Am J Sports Med , vol.25 , pp. 841-848
    • Schaefer, S.L.1    Ciarelli, M.J.2    Arnoczky, S.P.3    Ross, H.E.4
  • 29
    • 0031136430 scopus 로고    scopus 로고
    • Holmium:YAG laser-assisted capsular shift in a canine model: Intraarticular pressure and histologic observations
    • Pullin JG, Collier MA, Johnson LL, DeBault LE, Walls RC: Holmium:YAG laser-assisted capsular shift in a canine model: intraarticular pressure and histologic observations. J Shoulder Elbow Surg 1997, 6:272-285.
    • (1997) J Shoulder Elbow Surg , vol.6 , pp. 272-285
    • Pullin, J.G.1    Collier, M.A.2    Johnson, L.L.3    DeBault, L.E.4    Walls, R.C.5
  • 30
    • 0031031196 scopus 로고    scopus 로고
    • The effect of thermal heating on the length and histologic properties of the glenohumeral joint capsule
    • Hayashi K, Thabit G III, Massa KL, Bogdanske JJ, Cooley AJ, Orwin JF, Markel MD: The effect of thermal heating on the length and histologic properties of the glenohumeral joint capsule. Am J Sports Med 1997, 25:107-112. Cadaveric model showing thermal energy of 65°C causes significant shrinkage.
    • (1997) Am J Sports Med , vol.25 , pp. 107-112
    • Hayashi, K.1    Thabit III, G.2    Massa, K.L.3    Bogdanske, J.J.4    Cooley, A.J.5    Orwin, J.F.6    Markel, M.D.7
  • 31
    • 0029834228 scopus 로고    scopus 로고
    • The effect of nonablative laser energy on joint capsular properties: An in vitro histologic and biochemical study using a rabbit model
    • Hayashi K, Thabit G III, Vailas AC, Bogdanske JJ, Cooley AJ, Markel MD: The effect of nonablative laser energy on joint capsular properties: an in vitro histologic and biochemical study using a rabbit model. Am J Sports Med 1996, 24:640-646.
    • (1996) Am J Sports Med , vol.24 , pp. 640-646
    • Hayashi, K.1    Thabit III, G.2    Vailas, A.C.3    Bogdanske, J.J.4    Cooley, A.J.5    Markel, M.D.6
  • 32
    • 0012198775 scopus 로고
    • Treatment of unidirectional and multidirectional glenohumeral instability by an arthroscopic holmium:YAG laser-assisted capsular shift procedure: A pilot study
    • Neuchatel
    • Thabit G: Treatment of unidirectional and multidirectional glenohumeral instability by an arthroscopic holmium:YAG laser-assisted capsular shift procedure: a pilot study. In Laser Application in Arthroscopy. Neuchatel: 1994.
    • (1994) Laser Application in Arthroscopy
    • Thabit, G.1
  • 33
    • 15144350776 scopus 로고    scopus 로고
    • Temperature-specific device lets surgeons dial a degree
    • SLACK, Inc.
    • Beadling L: Temperature-specific device lets surgeons dial a degree. Orthopedics Today 1997, SLACK, Inc.
    • (1997) Orthopedics Today
    • Beadling, L.1
  • 35
    • 85038553860 scopus 로고    scopus 로고
    • Shrink don't slice: Joint repair without surgery
    • June 24
    • Rae-Dupree J: Shrink don't slice: joint repair without surgery. San Jose Mercury News, June 24, 1997.
    • (1997) San Jose Mercury News
    • Rae-Dupree, J.1
  • 36
    • 15144340128 scopus 로고    scopus 로고
    • Soft shoulder: Its amazing range of motion is a marvel of biomechanics. That's the problem
    • November
    • Thornton J: Soft shoulder: its amazing range of motion is a marvel of biomechanics. That's the problem. Men's Journal, November 1997.
    • (1997) Men's Journal
    • Thornton, J.1
  • 37
    • 85038554025 scopus 로고    scopus 로고
    • Pro athletes' cutting edge: Surgery saves careers, and we all benefit
    • January 26
    • Brink S: Pro athletes' cutting edge: surgery saves careers, and we all benefit. U.S. News & World Report January 26, 1998, 69-70.
    • (1998) U.S. News & World Report , pp. 69-70
    • Brink, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.