메뉴 건너뛰기




Volumn 82, Issue 11, 1998, Pages 1294-1300

Automatic full field analysis of perfusion images gained by scanning laser Doppler flowmetry

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BLOOD FLOW VELOCITY; CAPILLARY FLOW; HUMAN; IMAGE ANALYSIS; LASER DOPPLER FLOWMETRY; NORMAL HUMAN; OBSERVER VARIATION; OPTIC NERVE; PRIORITY JOURNAL; RELIABILITY; REPRODUCIBILITY; RETINA BLOOD FLOW; RETINA BLOOD VESSEL; RETINA CAPILLARY;

EID: 0031786440     PISSN: 00071161     EISSN: None     Source Type: Journal    
DOI: 10.1136/bjo.82.11.1294     Document Type: Article
Times cited : (140)

References (10)
  • 1
    • 85038546502 scopus 로고    scopus 로고
    • Verfahren und Gerät zur Messung der Fließgeschwindigkeit, insbesondere des Blutes. 1.6.94, European Patent No 94108430.3
    • Michelson G, Zinser G, Schmauß B. Verfahren und Gerät zur Messung der Fließgeschwindigkeit, insbesondere des Blutes. 1.6.94, European Patent No 94108430.3.
    • Michelson, G.1    Zinser, G.2    Schmauß, B.3
  • 2
    • 0029102801 scopus 로고
    • Zweidimensionale Kartierung der retinalen und papillären Mikrozirkulation mittels Scanning Laser Doppler Flowmetrie
    • Michelson G, Groh M, Langhans M, et al. Zweidimensionale Kartierung der retinalen und papillären Mikrozirkulation mittels Scanning Laser Doppler Flowmetrie. Klin Monatsbl Augenheilkd 1995;201:180-90.
    • (1995) Klin Monatsbl Augenheilkd , vol.201 , pp. 180-190
    • Michelson, G.1    Groh, M.2    Langhans, M.3
  • 3
    • 0029591154 scopus 로고
    • Two-dimensional mapping of the juxtapapillary perfusion by scanning laser Doppler flowmetry
    • Michelson G, Schmauß B. Two-dimensional mapping of the juxtapapillary perfusion by scanning laser Doppler flowmetry. Br J Ophthalmol 1995;79:1126-32.
    • (1995) Br J Ophthalmol , vol.79 , pp. 1126-1132
    • Michelson, G.1    Schmauß, B.2
  • 4
    • 0029892017 scopus 로고    scopus 로고
    • Principle, validity, and reliability of scanning laser Doppler flowmetry
    • Michelson G, Schmauss B, Langhans MJ, et al. Principle, validity, and reliability of scanning laser Doppler flowmetry. J Glaucoma 1996;5:99-105.
    • (1996) J Glaucoma , vol.5 , pp. 99-105
    • Michelson, G.1    Schmauss, B.2    Langhans, M.J.3
  • 5
    • 0001880061 scopus 로고
    • Principles of laser-Doppler flowmetry
    • Sheperd AP, Öberg PA, eds. Boston: Kluwer
    • Bonner RF, Nossal R. Principles of laser-Doppler flowmetry. In: Sheperd AP, Öberg PA, eds. Laser Doppler blood flowmetry. Vol 107. Boston: Kluwer, 1990:17-45.
    • (1990) Laser Doppler Blood Flowmetry , vol.107 , pp. 17-45
    • Bonner, R.F.1    Nossal, R.2
  • 8
    • 0003124916 scopus 로고    scopus 로고
    • Confocal scanning laser Doppler flowmetry of the retina and optic nerve head
    • Anderson DR, Drance SM, eds. Amsterdam: Kugler
    • Chauhan B. Confocal scanning laser Doppler flowmetry of the retina and optic nerve head. In: Anderson DR, Drance SM, eds. Encounters in glaucoma research 3. How to ascertain progression and outcome. Amsterdam: Kugler, 1996:263-76.
    • (1996) Encounters in Glaucoma Research 3. How to Ascertain Progression and Outcome , pp. 263-276
    • Chauhan, B.1
  • 9
    • 0030733194 scopus 로고    scopus 로고
    • Confocal scanning laser Doppler flowmetry: Experiments in a model flow system
    • Chauhan B, Smith FM. Confocal scanning laser Doppler flowmetry: experiments in a model flow system. J Glaucoma 1997;6:237-45.
    • (1997) J Glaucoma , vol.6 , pp. 237-245
    • Chauhan, B.1    Smith, F.M.2
  • 10
    • 0026800745 scopus 로고
    • Laser Doppler flowmetry in the optic nerve
    • Riva CE, Harino S, Petrig BL, et al. Laser Doppler flowmetry in the optic nerve. Exp Eye Res 1992;55:499-504.
    • (1992) Exp Eye Res , vol.55 , pp. 499-504
    • Riva, C.E.1    Harino, S.2    Petrig, B.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.