Volumn 17, Issue 6, 1998, Pages 85-87

Counterpressure: The concept that made the indirect measurement of blood pressure possible

Author keywords

[No Author keywords available]

Indexed keywords

AUSCULTATION; BLOOD PRESSURE MEASUREMENT; COUNTERPULSATION; HUMAN; OSCILLOMETRY; PNEUMATIC TOOL; REVIEW;

EID: 0031783699     PISSN: 07395175     EISSN: None     Source Type: Journal    
DOI: 10.1109/51.731326     Document Type: Review
Times cited : (3)

References (13)
  • 1
    • 0024119064 scopus 로고
    • Comparison of the auscultatory and oscillometric mean blood pressures in man
    • Davis G and Geddes LA: Comparison of the auscultatory and oscillometric mean blood pressures in man. Journ. Clin. Eng., 13(6):443-446, 1989.
    • (1989) Journ. Clin. Eng. , vol.13 , Issue.6 , pp. 443-446
    • Davis, G.1    Geddes, L.A.2
  • 2
    • 0025076764 scopus 로고
    • Ausculatory mean blood pressure
    • June 15-18, Washington, D.C.
    • Davis GG and Geddes LA: Ausculatory mean blood pressure. Proc. 23rd AAMI Conf. 1988 June 15-18, Washington, D.C., also Journ. Clin. Mon., 6(4):261-265, 1990.
    • (1988) Proc. 23rd AAMI Conf.
    • Davis, G.G.1    Geddes, L.A.2
  • 3
    • 0025076764 scopus 로고
    • Davis GG and Geddes LA: Ausculatory mean blood pressure. Proc. 23rd AAMI Conf. 1988 June 15-18, Washington, D.C., also Journ. Clin. Mon., 6(4):261-265, 1990.
    • (1990) Journ. Clin. Mon. , vol.6 , Issue.4 , pp. 261-265
  • 4
    • 0013959101 scopus 로고
    • Introduction of the auscultatory method of measuring blood pressure - Including a translation of Korotkoff's original paper
    • Geddes L.A., Hoff HE, and Badger AS: Introduction of the auscultatory method of measuring blood pressure - including a translation of Korotkoff's original paper. Cardiovascular Research Center Bull. 5(2):57-74, 1966.
    • (1966) Cardiovascular Research Center Bull. , vol.5 , Issue.2 , pp. 57-74
    • Geddes, L.A.1    Hoff, H.E.2    Badger, A.S.3
  • 6
    • 0042080747 scopus 로고
    • A simple and accurate form of sphygmometer or arterial pressure gauge contrived for clinical use
    • Hill L and Barnard H: A simple and accurate form of sphygmometer or arterial pressure gauge contrived for clinical use. Brit. M.J. 2:904, 1897.
    • (1897) Brit. M.J. , vol.2 , pp. 904
    • Hill, L.1    Barnard, H.2
  • 8
    • 0001125049 scopus 로고
    • Beiträge zur Kenntniss des Einflusses der Respirations bewegungen auf den Blutlauf im Aortensysteme
    • Ludwig C: Beiträge zur Kenntniss des Einflusses der Respirations bewegungen auf den Blutlauf im Aortensysteme, Müller's Arch Anat., 240-302, 1897.
    • (1897) Müller's Arch Anat. , pp. 240-302
    • Ludwig, C.1
  • 10
    • 0014535088 scopus 로고
    • The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure. Part 1
    • Posey JA., Geddes LA., Williams H, and Moore AG: The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure. Part 1. Cardiovasc. Res. Ctr. Bull. 8, (1):15-25, 1969.
    • (1969) Cardiovasc. Res. Ctr. Bull. , vol.8 , Issue.1 , pp. 15-25
    • Posey, J.A.1    Geddes, L.A.2    Williams, H.3    Moore, A.G.4
  • 11
    • 0018376613 scopus 로고
    • Noninvasive automatic determination of mean arterial pressure
    • Ramsey M: Noninvasive automatic determination of mean arterial pressure. Med. Biol. Eng. Comput. 17, 11-18, 1979.
    • (1979) Med. Biol. Eng. Comput. , vol.17 , pp. 11-18
    • Ramsey, M.1
  • 12
    • 0001517263 scopus 로고
    • Un nuovo sfigmomanometro
    • Riva Rocci S: Un nuovo sfigmomanometro. Gaz. Med. Torino. 47: 981-996, 1906.
    • (1906) Gaz. Med. Torino. , vol.47 , pp. 981-996
    • Riva Rocci, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.