메뉴 건너뛰기




Volumn 29, Issue 6, 1998, Pages 1133-1138

A comparison of four methods for distinguishing doppler signals from gaseous and particulate emboli

Author keywords

Embolism; Receiver operator characteristics; Ultrasonography, Doppler

Indexed keywords

AIR EMBOLISM; ARTICLE; COLOR ULTRASOUND FLOWMETRY; EMBOLISM; FOURIER TRANSFORMATION; PARTICULATE MATTER; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; TRANSCRANIAL DOPPLER ULTRASOUND;

EID: 0031780171     PISSN: 00392499     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.STR.29.6.1133     Document Type: Article
Times cited : (42)

References (13)
  • 1
    • 0028049036 scopus 로고
    • Clinical relevance of intraoperative embolization detected by transcranial Doppler ultrasonography during carotid endarterectomy: A prospective study of 100 patients
    • Gaunt ME, Martin PJ, Smith JL, Rimmer T, Cherryman G, Ratliff DA, Bell PR, Naylor AR. Clinical relevance of intraoperative embolization detected by transcranial Doppler ultrasonography during carotid endarterectomy: a prospective study of 100 patients. Br J Surg. 1994;81: 1435-1439.
    • (1994) Br J Surg , vol.81 , pp. 1435-1439
    • Gaunt, M.E.1    Martin, P.J.2    Smith, J.L.3    Rimmer, T.4    Cherryman, G.5    Ratliff, D.A.6    Bell, P.R.7    Naylor, A.R.8
  • 3
    • 0000259979 scopus 로고
    • The intensity of the Doppler signal caused by arterial emboli depends on embolus type and size
    • Russell D, Brucher RR, Madden KP, Clark WM, Sandset PM, Zivin JA. The intensity of the Doppler signal caused by arterial emboli depends on embolus type and size. Stroke. 1992;23:158.
    • (1992) Stroke , vol.23 , pp. 158
    • Russell, D.1    Brucher, R.R.2    Madden, K.P.3    Clark, W.M.4    Sandset, P.M.5    Zivin, J.A.6
  • 5
    • 0027434362 scopus 로고
    • Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in vitro model
    • Markus HS, Brown MM. Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in vitro model. Stroke. 1993;24:1-5.
    • (1993) Stroke , vol.24 , pp. 1-5
    • Markus, H.S.1    Brown, M.M.2
  • 6
    • 0028218713 scopus 로고
    • Detection of circulating cerebral emboli using Doppler ultrasound in a sheep model
    • Markus H, Loh A, Brown MM. Detection of circulating cerebral emboli using Doppler ultrasound in a sheep model. J Neurol Sci. 1994;122:117-124.
    • (1994) J Neurol Sci , vol.122 , pp. 117-124
    • Markus, H.1    Loh, A.2    Brown, M.M.3
  • 7
    • 0027520512 scopus 로고
    • Quantification of ultrasound emboli signals in patients with cardiac and carotid disease
    • Grosset DG, Georgiadis D, Kelman AW, Lees KR. Quantification of ultrasound emboli signals in patients with cardiac and carotid disease. Stroke. 1993;24:1922-1924.
    • (1993) Stroke , vol.24 , pp. 1922-1924
    • Grosset, D.G.1    Georgiadis, D.2    Kelman, A.W.3    Lees, K.R.4
  • 8
    • 0027933759 scopus 로고
    • Differentiation between gaseous and formed embolic materials in vivo: Application in prosthetic heart valve patients
    • Georgiadis D, Mackay TG, Kelman AW, Grosset DG, Wheatley DJ, Lees KR. Differentiation between gaseous and formed embolic materials in vivo: application in prosthetic heart valve patients. Stroke. 1994;25: 1559-1563.
    • (1994) Stroke , vol.25 , pp. 1559-1563
    • Georgiadis, D.1    Mackay, T.G.2    Kelman, A.W.3    Grosset, D.G.4    Wheatley, D.J.5    Lees, K.R.6
  • 9
    • 0028203282 scopus 로고
    • The effect of velocity on the appearance of embolic signals studied in transcranial Doppler models
    • Droste DW, Markus HS, Nassiri D, Brown MM. The effect of velocity on the appearance of embolic signals studied in transcranial Doppler models. Stroke. 1994;25:986-991.
    • (1994) Stroke , vol.25 , pp. 986-991
    • Droste, D.W.1    Markus, H.S.2    Nassiri, D.3    Brown, M.M.4
  • 10
    • 0028125815 scopus 로고
    • Detection and volume estimation of embolic air in the middle cerebral artery using transcranial Doppler sonography
    • Bunegin L, Wahl D, Albin MS. Detection and volume estimation of embolic air in the middle cerebral artery using transcranial Doppler sonography. Stroke. 1994;25:593-600.
    • (1994) Stroke , vol.25 , pp. 593-600
    • Bunegin, L.1    Wahl, D.2    Albin, M.S.3
  • 12
    • 0029453511 scopus 로고
    • Exploration of the embolus to blood power ratio model (EBR) for characterizing microemboli detected in the middle cerebral artery
    • November 7-10, Seattle, Wash.
    • Moehring MA, Spencer MP, Davis DL, Demuth RP. Exploration of the embolus to blood power ratio model (EBR) for characterizing microemboli detected in the middle cerebral artery. In: Program and abstracts of the IEEE Ultrasonics Symposium; November 7-10, 1995; Seattle, Wash.
    • (1995) Program and Abstracts of the IEEE Ultrasonics Symposium
    • Moehring, M.A.1    Spencer, M.P.2    Davis, D.L.3    Demuth, R.P.4
  • 13
    • 0028218713 scopus 로고
    • Detection of circulating cerebral emboli using Doppler ultrasound in a sheep model
    • Markus H, Loh A, Brown MM. Detection of circulating cerebral emboli using Doppler ultrasound in a sheep model. J Neurol Sci. 1994;122: 117-124.
    • (1994) J Neurol Sci , vol.122 , pp. 117-124
    • Markus, H.1    Loh, A.2    Brown, M.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.