메뉴 건너뛰기




Volumn 13, Issue 5, 1998, Pages 533-540

Central venous pressure, pulmonary capillary wedge pressure and intrathoracic blood volumes as preload indicators in cardiac surgery patients

Author keywords

Cardiac filling pressures; Cardiac output measurement; Cardiac preload; Intrathoracic blood volume; Thermal dye dilution

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD VOLUME; CENTRAL VENOUS PRESSURE; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; FEMALE; HEART INDEX; HEART PRELOAD; HEART STROKE VOLUME; HUMAN; ISCHEMIC HEART DISEASE; LUNG CAPILLARY PRESSURE; MALE; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; THERMODILUTION;

EID: 0031779157     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1010-7940(98)00063-3     Document Type: Article
Times cited : (172)

References (26)
  • 1
    • 0026438408 scopus 로고
    • What value does the recording of intrathoracic blood volume have in clinical practice?
    • Hedenstierna G. What value does the recording of intrathoracic blood volume have in clinical practice?. Int Care Med 1992;18:137-138.
    • (1992) Int Care Med , vol.18 , pp. 137-138
    • Hedenstierna, G.1
  • 2
    • 0021347395 scopus 로고
    • Reliability of clinical monitoring to assess blood volume in critically ill patients
    • Shippy CR, Appel RL, Shoemaker WC. Reliability of clinical monitoring to assess blood volume in critically ill patients. Crit Care Med 1984;12:107-112.
    • (1984) Crit Care Med , vol.12 , pp. 107-112
    • Shippy, C.R.1    Appel, R.L.2    Shoemaker, W.C.3
  • 3
    • 0020527769 scopus 로고
    • Effect of positive end-expiratory pressure on pulmonary capillary wedge pressure
    • Gershan JA. Effect of positive end-expiratory pressure on pulmonary capillary wedge pressure. Heart Lung 1983;12:143-148.
    • (1983) Heart Lung , vol.12 , pp. 143-148
    • Gershan, J.A.1
  • 4
    • 0017661046 scopus 로고
    • The effect of vascular volume on positive end-expiratory pressure induced cardiac output depression and wedge-left atrial pressure discrepancy
    • Zarins CK, Virgilio RW, Smith DE, Peters RM. The effect of vascular volume on positive end-expiratory pressure induced cardiac output depression and wedge-left atrial pressure discrepancy. J Surg Res 1977;23:348-360.
    • (1977) J Surg Res , vol.23 , pp. 348-360
    • Zarins, C.K.1    Virgilio, R.W.2    Smith, D.E.3    Peters, R.M.4
  • 5
    • 0016401628 scopus 로고
    • Pulmonary complications of the flow directed balloon tipped catheter
    • Foote GA, Shabel SI, Hodges M. Pulmonary complications of the flow directed balloon tipped catheter. N Engl J Med 1974;290:927-931.
    • (1974) N Engl J Med , vol.290 , pp. 927-931
    • Foote, G.A.1    Shabel, S.I.2    Hodges, M.3
  • 6
    • 0005566366 scopus 로고
    • A community-wide assessment of the use of pulmonary artery catheters in patients with acute myocardial infarction
    • Gore JM, Goldberg R, Spodick D, Alpert J, Dalen JE. A community-wide assessment of the use of pulmonary artery catheters in patients with acute myocardial infarction. Chest 1987;98:1331-1335.
    • (1987) Chest , vol.98 , pp. 1331-1335
    • Gore, J.M.1    Goldberg, R.2    Spodick, D.3    Alpert, J.4    Dalen, J.E.5
  • 8
    • 0031017937 scopus 로고    scopus 로고
    • Pulmonary artery flotation catheters
    • Chernow B. Pulmonary artery flotation catheters. Chest 1997; 111:261-262.
    • (1997) Chest , vol.111 , pp. 261-262
    • Chernow, B.1
  • 9
    • 0029783123 scopus 로고    scopus 로고
    • Is it time to pull the pulmonary artery catheter?
    • Dalen JE, Bone RC. Is it time to pull the pulmonary artery catheter?. J Am Med Assoc 1996;276:916-918.
    • (1996) J Am Med Assoc , vol.276 , pp. 916-918
    • Dalen, J.E.1    Bone, R.C.2
  • 10
    • 0007330196 scopus 로고    scopus 로고
    • The pulmonary artery catheter: Too soon for its swan song?
    • Dobb G. The pulmonary artery catheter: too soon for its swan song?. Int Care World 1996;13:139-140.
    • (1996) Int Care World , vol.13 , pp. 139-140
    • Dobb, G.1
  • 11
    • 0029795650 scopus 로고    scopus 로고
    • Swan song for the swan-ganz catheter?
    • Soni N. Swan song for the swan-ganz catheter?. Br Med J 1996; 313:763-764.
    • (1996) Br Med J , vol.313 , pp. 763-764
    • Soni, N.1
  • 12
    • 13144272381 scopus 로고
    • Intravascular volume status indicators: Effective central venous pressure, effective pulmonary wedge pressure or intrathor-zacic blood volume - Which one is better?
    • Gödje O, Wellensiek N, Zeravik J, Blümel G, Zimmerman G, Pfeiffer UJ. Intravascular volume status indicators: effective central venous pressure, effective pulmonary wedge pressure or intrathor-[zacic blood volume - which one is better? Eur Surg Res 1989;21; 88.
    • (1989) Eur Surg Res , vol.21 , pp. 88
    • Gödje, O.1    Wellensiek, N.2    Zeravik, J.3    Blümel, G.4    Zimmerman, G.5    Pfeiffer, U.J.6
  • 13
    • 0030475788 scopus 로고    scopus 로고
    • Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end-diastolic volume as indicators of cardiac preload
    • Lichtwarck-Aschoff M, Beale R, Pfeiffer UJ. Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end-diastolic volume as indicators of cardiac preload. J Crit Care 1996;11:180-188.
    • (1996) J Crit Care , vol.11 , pp. 180-188
    • Lichtwarck-Aschoff, M.1    Beale, R.2    Pfeiffer, U.J.3
  • 14
    • 0026689496 scopus 로고
    • Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation
    • Lichtwark-Aschoff M, Zeravik J, Pfeiffer UJ. Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation. Int Care Med 1992;18:142-147.
    • (1992) Int Care Med , vol.18 , pp. 142-147
    • Lichtwark-Aschoff, M.1    Zeravik, J.2    Pfeiffer, U.J.3
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;8:307-310.
    • (1986) Lancet , vol.8 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 0015136519 scopus 로고
    • Conservation of thermal indicator in lung circulation
    • Arfors KE, Malmberg P, Pvek K. Conservation of thermal indicator in lung circulation. Cardiovasc Res 1971;5:530-535.
    • (1971) Cardiovasc Res , vol.5 , pp. 530-535
    • Arfors, K.E.1    Malmberg, P.2    Pvek, K.3
  • 20
    • 0022550639 scopus 로고
    • Relationship between cardiac output and transit times for dye and thermal indicators in central circulation
    • Carlile PV, Becket RC, Grey BA. Relationship between cardiac output and transit times for dye and thermal indicators in central circulation. J Appl Physiol 1986;60:1363-1369.
    • (1986) J Appl Physiol , vol.60 , pp. 1363-1369
    • Carlile, P.V.1    Becket, R.C.2    Grey, B.A.3
  • 21
    • 0022236761 scopus 로고
    • The slowing of sinus rhythm during thermodilution cardiac output determination and the effect of altering injectate temperature
    • Harris R, Miller C, Beatty C, Rosenfeld G, Rogers M. The slowing of sinus rhythm during thermodilution cardiac output determination and the effect of altering injectate temperature. Anaesthesiology 1985; 63:540-541.
    • (1985) Anaesthesiology , vol.63 , pp. 540-541
    • Harris, R.1    Miller, C.2    Beatty, C.3    Rosenfeld, G.4    Rogers, M.5
  • 22
    • 0029916814 scopus 로고    scopus 로고
    • A comparison of pulmonary and femoral artery thermodilution cardiac indices in paediatric intensive care patients
    • McLuckie A, Marsh M, Andersen D, Murdoch M. A comparison of pulmonary and femoral artery thermodilution cardiac indices in paediatric intensive care patients. Acta Paediatr 1996;85:336-338.
    • (1996) Acta Paediatr , vol.85 , pp. 336-338
    • McLuckie, A.1    Marsh, M.2    Andersen, D.3    Murdoch, M.4
  • 23
    • 85047676508 scopus 로고
    • Acute pulmonary microembolism induces different changes of preload and contraction pattern in the canine right ventricle
    • Zwissler B, Forst H, Messmer K. Acute pulmonary microembolism induces different changes of preload and contraction pattern in the canine right ventricle. Cardiovasc Res 1990;24:285-295.
    • (1990) Cardiovasc Res , vol.24 , pp. 285-295
    • Zwissler, B.1    Forst, H.2    Messmer, K.3
  • 25
    • 0342462883 scopus 로고    scopus 로고
    • Are arterial thermal dye dilution measurements comparable to pulmonary arterial thermal dilution concerning accuracy and reproducibility?
    • Gödje O, Peyerl M, Fischlein T, Pfeiffer U, Reichart B. Are arterial thermal dye dilution measurements comparable to pulmonary arterial thermal dilution concerning accuracy and reproducibility?. Crit care Med 1997;25 (Suppl. 1):50.
    • (1997) Crit Care Med , vol.25 , Issue.1 SUPPL. , pp. 50
    • Gödje, O.1    Peyerl, M.2    Fischlein, T.3    Pfeiffer, U.4    Reichart, B.5
  • 26
    • 0030860506 scopus 로고    scopus 로고
    • Stationsbezogenes Labor-Monitoring auf der Intensivstation - Blutgas-, Elektrolyt-, glucose-, Hämoglobin- und Lactat-Bestimmungen mit dem Ciba-Corning 865 Analyse-System
    • Gödje O, Fuchs A, Dewald O, Fischlein T, Reichart B. Stationsbezogenes Labor-Monitoring auf der Intensivstation - Blutgas-, Elektrolyt-, glucose-, Hämoglobin- und Lactat-Bestimmungen mit dem Ciba-Corning 865 Analyse-System. Anäesthesiol Intensivmed Notfallmed Schmerzther 1997;32:549-556.
    • (1997) Anäesthesiol Intensivmed Notfallmed Schmerzther , vol.32 , pp. 549-556
    • Gödje, O.1    Fuchs, A.2    Dewald, O.3    Fischlein, T.4    Reichart, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.