메뉴 건너뛰기




Volumn 14, Issue 3, 1998, Pages 151-158

Changes in astigmatism after ptosis surgery measured by corneal topography

Author keywords

Astigmatism; Corneal topography; EyeSys topographic analyzer; Ptosis

Indexed keywords

ARTICLE; ASTIGMATISM; COMPUTER ANALYSIS; CORNEA; EYE SURGERY; EYELID; HUMAN; HUMAN TISSUE; PLASTIC SURGERY; PRIORITY JOURNAL; PTOSIS; SCLERA BUCKLING PROCEDURE; STRABISMUS SURGERY; TOPOGRAPHY;

EID: 0031777853     PISSN: 07409303     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002341-199805000-00001     Document Type: Article
Times cited : (61)

References (21)
  • 1
    • 0018864781 scopus 로고
    • Congenital blepharoptosis, anisometropia and amblyopia
    • Merriam WW, Ellis FA, Helveston EM. Congenital blepharoptosis, anisometropia and amblyopia. Am J Ophthalmol 1980;89:401-7.
    • (1980) Am J Ophthalmol , vol.89 , pp. 401-407
    • Merriam, W.W.1    Ellis, F.A.2    Helveston, E.M.3
  • 5
    • 0026694885 scopus 로고
    • The effect of trabeculectomy on corneal topography
    • Rosen WJ, Mannis MJ, Brandt JD. The effect of trabeculectomy on corneal topography. Ophthalmic Surg 1992; 23:395-8.
    • (1992) Ophthalmic Surg , vol.23 , pp. 395-398
    • Rosen, W.J.1    Mannis, M.J.2    Brandt, J.D.3
  • 6
    • 0029072184 scopus 로고
    • The effect of trabeculectomy on refraction, keratometry and corneal topography
    • Claridge KG, Galbraith JK, Karmel V, Bates AK. The effect of trabeculectomy on refraction, keratometry and corneal topography. Eye 1995;9:292-8.
    • (1995) Eye , vol.9 , pp. 292-298
    • Claridge, K.G.1    Galbraith, J.K.2    Karmel, V.3    Bates, A.K.4
  • 8
    • 0026543298 scopus 로고
    • Corneal topographic changes following strabismus surgery in Graves' disease
    • Kwitko S, Feldon S, McDonnell PJ. Corneal topographic changes following strabismus surgery in Graves' disease. Cornea 1992;11:36-40.
    • (1992) Cornea , vol.11 , pp. 36-40
    • Kwitko, S.1    Feldon, S.2    McDonnell, P.J.3
  • 9
    • 0019120380 scopus 로고
    • The changes in refractive status following routine strabismus surgery
    • Thompson WE, Reinecke RD. The changes in refractive status following routine strabismus surgery. J Pediatr Ophthalmol Strabismus 1980;17:372-4.
    • (1980) J Pediatr Ophthalmol Strabismus , vol.17 , pp. 372-374
    • Thompson, W.E.1    Reinecke, R.D.2
  • 10
    • 0344199463 scopus 로고
    • Changes in refraction following operation for strabismus
    • Marshall D. Changes in refraction following operation for strabismus. Arch Ophthalmol 1936;15:1020-31.
    • (1936) Arch Ophthalmol , vol.15 , pp. 1020-1031
    • Marshall, D.1
  • 11
    • 0018855182 scopus 로고
    • The relationship between soft tissue anomalies around the orbit and globe and astigmatic refractive errors: A preliminary report
    • Cuttone JM, Durso F, Miller M, Evans LS. The relationship between soft tissue anomalies around the orbit and globe and astigmatic refractive errors: a preliminary report. J Pediatr Ophthalmol Strabismus 1980;17:29-36.
    • (1980) J Pediatr Ophthalmol Strabismus , vol.17 , pp. 29-36
    • Cuttone, J.M.1    Durso, F.2    Miller, M.3    Evans, L.S.4
  • 14
    • 0000910994 scopus 로고
    • Notes on three cases of acquired astigmatism associated with Meibomian cysts
    • Ormond AW. Notes on three cases of acquired astigmatism associated with Meibomian cysts. Br J Ophthalmol 1921;5:117.
    • (1921) Br J Ophthalmol , vol.5 , pp. 117
    • Ormond, A.W.1
  • 15
    • 0017328027 scopus 로고
    • Refractive errors associated with hemangiomas of the eyelids and orbit in infancy
    • Robb RM. Refractive errors associated with hemangiomas of the eyelids and orbit in infancy. Am J Ophthalmol 1977; 83:52-8.
    • (1977) Am J Ophthalmol , vol.83 , pp. 52-58
    • Robb, R.M.1
  • 16
    • 0020375895 scopus 로고
    • Congenital Ptosis; Results of treatment using lyophilized fascia lata for frontalis suspensions
    • Broughton WL, Matthews JG, Harris D. Congenital Ptosis; Results of treatment using lyophilized fascia lata for frontalis suspensions. Ophthalmology 1982;89:1261-6.
    • (1982) Ophthalmology , vol.89 , pp. 1261-1266
    • Broughton, W.L.1    Matthews, J.G.2    Harris, D.3
  • 17
    • 0001041654 scopus 로고
    • Alignment errors and working distance directly influence the accuracy of corneal topography measurements
    • ARVO abstract 1509-66
    • Nieves JE, Applegate RA. Alignment errors and working distance directly influence the accuracy of corneal topography measurements. ARVO abstract 1509-66. Invest Ophthalmol Vis Sci 1992;33:993.
    • (1992) Invest Ophthalmol Vis Sci , vol.33 , pp. 993
    • Nieves, J.E.1    Applegate, R.A.2
  • 19
    • 0026970445 scopus 로고
    • Comparison office accuracy and reproducibility of the keratometer and the EyeSys Comeal Analysis System Model I
    • Koch DD, Wakil JS, Samuelson SW, Haft EA. Comparison office accuracy and reproducibility of the keratometer and the EyeSys Comeal Analysis System Model I. J Cataract Refract Surg 1992;18:342-7.
    • (1992) J Cataract Refract Surg , vol.18 , pp. 342-347
    • Koch, D.D.1    Wakil, J.S.2    Samuelson, S.W.3    Haft, E.A.4
  • 20
    • 0026732712 scopus 로고
    • Practical aspects of a corneal topography system
    • McCarey BE, Zurawski CA, O'Shea DS. Practical aspects of a corneal topography system. CLAO J 1992;18:248-54.
    • (1992) CLAO J , vol.18 , pp. 248-254
    • McCarey, B.E.1    Zurawski, C.A.2    O'Shea, D.S.3
  • 21
    • 0026565702 scopus 로고
    • Accuracy and precision of the corneal analysis system and the topographic modeling system
    • Wilson SE, Verity SM, Conger DL. Accuracy and precision of the corneal analysis system and the topographic modeling system. Cornea 1992;11:28-35.
    • (1992) Cornea , vol.11 , pp. 28-35
    • Wilson, S.E.1    Verity, S.M.2    Conger, D.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.