메뉴 건너뛰기




Volumn 11, Issue 4, 1998, Pages 942-945

Reproducibility of spirometrically controlled CT lung densitometry in a clinical setting

Author keywords

Computed tomography; Densitometry; Lung; Techniques

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DENSITOMETRY; FEMALE; HISTOGRAM; HOSPITALIZATION; HUMAN; LUNG DISEASE; LUNG FUNCTION; LUNG VOLUME; MALE; PRIORITY JOURNAL; REPRODUCIBILITY; SPIROMETRY; TECHNIQUE; TISSUE SECTION; VITAL CAPACITY;

EID: 0031777418     PISSN: 09031936     EISSN: None     Source Type: Journal    
DOI: 10.1183/09031936.98.11040942     Document Type: Article
Times cited : (47)

References (21)
  • 1
    • 0027066960 scopus 로고
    • Detection and quantification of pulmonary emphysema by computed tomography: A window of opportunity
    • Morgan MDL. Detection and quantification of pulmonary emphysema by computed tomography: a window of opportunity. Thorax 1992; 47: 1001-1004.
    • (1992) Thorax , vol.47 , pp. 1001-1004
    • Morgan, M.D.L.1
  • 2
    • 0029021066 scopus 로고
    • Can computed tomography quantify pulmonary emphysema?
    • Gevenois PA, Yernault JC. Can computed tomography quantify pulmonary emphysema? Eur Respir J 1995; 5: 843-848.
    • (1995) Eur Respir J , vol.5 , pp. 843-848
    • Gevenois, P.A.1    Yernault, J.C.2
  • 4
    • 0029891484 scopus 로고    scopus 로고
    • Pulmonary emphysema: Quantitative CT during expiration
    • Gevenois PA, De Vuyst P, Sy M, et al. Pulmonary emphysema: quantitative CT during expiration. Radiology 1996; 199: 825-829.
    • (1996) Radiology , vol.199 , pp. 825-829
    • Gevenois, P.A.1    De Vuyst, P.2    Sy, M.3
  • 5
    • 0025964353 scopus 로고
    • Lung CT density correlates with measurements of airflow limitation and the diffusing capacity
    • Gould GA, Redpath AT, Ryan M, et al. Lung CT density correlates with measurements of airflow limitation and the diffusing capacity. Eur Respir J 1991; 4: 141-146.
    • (1991) Eur Respir J , vol.4 , pp. 141-146
    • Gould, G.A.1    Redpath, A.T.2    Ryan, M.3
  • 6
    • 0030916523 scopus 로고    scopus 로고
    • Patients with emphysema: Quantitative CT analysis before and after lung volume reduction surgery
    • Bae KT, Slone RM, Gierada DS, Yusen RD, Cooper JD. Patients with emphysema: quantitative CT analysis before and after lung volume reduction surgery. Radiology 1997; 203: 705-714.
    • (1997) Radiology , vol.203 , pp. 705-714
    • Bae, K.T.1    Slone, R.M.2    Gierada, D.S.3    Yusen, R.D.4    Cooper, J.D.5
  • 7
    • 0029826276 scopus 로고    scopus 로고
    • Changes in lung volume and volume of emphysema after unilateral lung reduction surgery: Analysis with CT lung densitometry
    • Holbert JM, Brown ML, Sciurba FC, et al. Changes in lung volume and volume of emphysema after unilateral lung reduction surgery: analysis with CT lung densitometry. Radiology 1996; 201: 793-797.
    • (1996) Radiology , vol.201 , pp. 793-797
    • Holbert, J.M.1    Brown, M.L.2    Sciurba, F.C.3
  • 10
    • 0029801023 scopus 로고    scopus 로고
    • Density resolution in quantitative computed tomography of foam and lung
    • Kemerink GJ, Kruize HH, Lamers RJS. Density resolution in quantitative computed tomography of foam and lung. Med Phys 1996; 23: 1697-1708.
    • (1996) Med Phys , vol.23 , pp. 1697-1708
    • Kemerink, G.J.1    Kruize, H.H.2    Lamers, R.J.S.3
  • 11
    • 0031473144 scopus 로고    scopus 로고
    • CT lung densitometry: Dependence of CT number histograms on sample volume and consequences for scan protocol comparability
    • Kemerink GJ, Kruize HH, Lamers RJS, van Engelshoven JMA. CT lung densitometry: dependence of CT number histograms on sample volume and consequences for scan protocol comparability. J Comput Assist Tomogr 1997; 21: 948-954.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 948-954
    • Kemerink, G.J.1    Kruize, H.H.2    Lamers, R.J.S.3    Van Engelshoven, J.M.A.4
  • 12
    • 0030821685 scopus 로고    scopus 로고
    • The CTs sample volume as an approximate, instrumental measure for density resolution in densitometry of the lungs
    • Kemerink GJ, Kruize HH, Lamers RJS. The CTs sample volume as an approximate, instrumental measure for density resolution in densitometry of the lungs. Med Phys 1997; 24: 1615-1620.
    • (1997) Med Phys , vol.24 , pp. 1615-1620
    • Kemerink, G.J.1    Kruize, H.H.2    Lamers, R.J.S.3
  • 13
    • 0028856696 scopus 로고
    • Reproducibility of quantitative, spirometrically-controlled CT
    • Kohz P, Stäbler A, Beinert T, et al. Reproducibility of quantitative, spirometrically-controlled CT. Radiology 1995; 197: 539-542.
    • (1995) Radiology , vol.197 , pp. 539-542
    • Kohz, P.1    Stäbler, A.2    Beinert, T.3
  • 14
    • 0023695782 scopus 로고
    • "Density mask": An objective method to quantitate emphysema using computed tomography
    • Müller NL, Staples CA, Miller RR, Abboud RT. "Density mask": an objective method to quantitate emphysema using computed tomography. Chest 1988; 94: 782-787.
    • (1988) Chest , vol.94 , pp. 782-787
    • Müller, N.L.1    Staples, C.A.2    Miller, R.R.3    Abboud, R.T.4
  • 15
    • 0023840638 scopus 로고
    • CT measurements of lung density in life can quantitate distal airspace enlargement: An essential defining feature of human emphysema
    • Gould GA, MacNee W, McLean A, et al. CT measurements of lung density in life can quantitate distal airspace enlargement: an essential defining feature of human emphysema. Am Rev Respir Dis 1988; 137: 380-392.
    • (1988) Am Rev Respir Dis , vol.137 , pp. 380-392
    • Gould, G.A.1    MacNee, W.2    McLean, A.3
  • 16
    • 0025349284 scopus 로고
    • Measurement of pulmonary parenchymal attenuation: Use of spirometric gating with quantitative CT
    • Kalender WA, Rienmüller R, Seissler W, Behr J, Welke M, Fichte H. Measurement of pulmonary parenchymal attenuation: use of spirometric gating with quantitative CT. Radiology 1990; 175: 265-268.
    • (1990) Radiology , vol.175 , pp. 265-268
    • Kalender, W.A.1    Rienmüller, R.2    Seissler, W.3    Behr, J.4    Welke, M.5    Fichte, H.6
  • 17
    • 0029737657 scopus 로고    scopus 로고
    • On the generation of short-axis and radial long-axis slices in thallium-201 myocardial perfusion single-photon emission tomography
    • van Hastenberg RPJM, Kemerink GJ, Hasman A. On the generation of short-axis and radial long-axis slices in thallium-201 myocardial perfusion single-photon emission tomography. Eur J Nucl Med 1996; 23: 924-931.
    • (1996) Eur J Nucl Med , vol.23 , pp. 924-931
    • Van Hastenberg, R.P.J.M.1    Kemerink, G.J.2    Hasman, A.3
  • 18
    • 0027386821 scopus 로고
    • Dynamic pulmonary CT: Findings in healthy adult men
    • Webb RW, Stern EJ, Kanth N, Gamsu G. Dynamic pulmonary CT: findings in healthy adult men. Radiology 1993; 186: 117-124.
    • (1993) Radiology , vol.186 , pp. 117-124
    • Webb, R.W.1    Stern, E.J.2    Kanth, N.3    Gamsu, G.4
  • 19
    • 0018571939 scopus 로고
    • Pulmonary tissue attenuation with computed tomography: Comparison of inspiratory and expiratory scans
    • Robinson P, Kreel L. Pulmonary tissue attenuation with computed tomography: comparison of inspiratory and expiratory scans. J Comput Assist Tomogr 1979; 3: 740-748.
    • (1979) J Comput Assist Tomogr , vol.3 , pp. 740-748
    • Robinson, P.1    Kreel, L.2
  • 20
    • 0028095028 scopus 로고
    • Chronic obstructive pulmonary disease: Evaluation with spirometrically controlled CT lung densitometry
    • Lamers RJS, Thelissen GR, Kessels AG, Vlouters EF, van Engelshoven JM. Chronic obstructive pulmonary disease: evaluation with spirometrically controlled CT lung densitometry. Radiology 1994; 1993: 109-113.
    • (1994) Radiology , vol.1993 , pp. 109-113
    • Lamers, R.J.S.1    Thelissen, G.R.2    Kessels, A.G.3    Vlouters, E.F.4    Van Engelshoven, J.M.5
  • 21
    • 0026038935 scopus 로고
    • Lung function testing: Selection of reference values and interpretative strategies
    • American Thoracic Society. Lung function testing: selection of reference values and interpretative strategies. Am Rev Respir Dis 1991; 144: 1202-1218.
    • (1991) Am Rev Respir Dis , vol.144 , pp. 1202-1218


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.