메뉴 건너뛰기




Volumn 24, Issue 5, 1998, Pages 487-493

Determination of functional residual capacity (FRC) by multibreath nitrogen washout in a lung model and in mechanically ventilated patients. Accuracy depends on continuous dynamic compensation for changes of gas sampling delay time

Author keywords

Acute lung injury; Aged; Chronic obstructive pulmonary disease; Critical care; Functional residual capacity; Lung volume measurement; Mechanical ventilation

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL VENTILATION; CHRONIC OBSTRUCTIVE LUNG DISEASE; CLINICAL ARTICLE; FUNCTIONAL RESIDUAL CAPACITY; GAS ANALYSIS; GAS FLOW; HUMAN; INTENSIVE CARE; LUNG MODEL; NITROGEN WASHOUT;

EID: 0031777354     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/s001340050601     Document Type: Article
Times cited : (38)

References (19)
  • 1
    • 0027482718 scopus 로고
    • The recording of FRC - Is it of importance and can it be made simple?
    • Hedenstierna G (1993) The recording of FRC - is it of importance and can it be made simple? Intensive Care Med 19:365-366
    • (1993) Intensive Care Med , vol.19 , pp. 365-366
    • Hedenstierna, G.1
  • 2
    • 0001631321 scopus 로고
    • Studies on intrapulmonary mixture of gases. Open circuit method for measuring residual air
    • Darling RC, Richards DW, Cournand A (1940) Studies on intrapulmonary mixture of gases. Open circuit method for measuring residual air. J Clin Invest 19: 609-618
    • (1940) J Clin Invest , vol.19 , pp. 609-618
    • Darling, R.C.1    Richards, D.W.2    Cournand, A.3
  • 5
    • 0025309025 scopus 로고
    • Design and validation of an indicator gas injector for multiple gas washout tests in mechanically ventilated patients
    • Huygen PE, Feenstra BW, Holland WP, Ince C, Stam H, Bruining HA (1990) Design and validation of an indicator gas injector for multiple gas washout tests in mechanically ventilated patients. Crit Care Med 18: 754-759
    • (1990) Crit Care Med , vol.18 , pp. 754-759
    • Huygen, P.E.1    Feenstra, B.W.2    Holland, W.P.3    Ince, C.4    Stam, H.5    Bruining, H.A.6
  • 6
    • 0026253899 scopus 로고
    • Correction of pneumotachograph signal for changes in viscosity during nitrogen washout
    • Kox WJ, Mills CJ, Hale T (1991) Correction of pneumotachograph signal for changes in viscosity during nitrogen washout. Clin Phys Physiol Meas 12: 359-365
    • (1991) Clin Phys Physiol Meas , vol.12 , pp. 359-365
    • Kox, W.J.1    Mills, C.J.2    Hale, T.3
  • 7
    • 0027490262 scopus 로고
    • A simple method to estimate functional residual capacity in mechanically ventilated patients
    • Fretschner R, Deusch H, Weitnauer A, Brunner JX (1993) A simple method to estimate functional residual capacity in mechanically ventilated patients. Intensive Care Med 19: 372-376
    • (1993) Intensive Care Med , vol.19 , pp. 372-376
    • Fretschner, R.1    Deusch, H.2    Weitnauer, A.3    Brunner, J.X.4
  • 8
    • 0021169573 scopus 로고
    • Pneumolachographs: Theory and clinical application
    • Sullivan WJ, Peters GM, Enright PL (1984) Pneumolachographs: Theory and clinical application. Respir Care 29: 736-749
    • (1984) Respir Care , vol.29 , pp. 736-749
    • Sullivan, W.J.1    Peters, G.M.2    Enright, P.L.3
  • 9
    • 0020800408 scopus 로고
    • Direct accurate gas flow measurement in the patient: Compensation for unavoidable error
    • Brunner JX, Langenstein H, Wolff G (1983) Direct accurate gas flow measurement in the patient: compensation for unavoidable error. Med Prog Technol 9: 233-238
    • (1983) Med Prog Technol , vol.9 , pp. 233-238
    • Brunner, J.X.1    Langenstein, H.2    Wolff, G.3
  • 11
    • 0029859539 scopus 로고    scopus 로고
    • The accuracy of pneumotachograph measurements during mechanical ventilation
    • Kreit JW, Sciurba FC (1996) The accuracy of pneumotachograph measurements during mechanical ventilation. Am J Respir Crit Care Med 154: 913-917
    • (1996) Am J Respir Crit Care Med , vol.154 , pp. 913-917
    • Kreit, J.W.1    Sciurba, F.C.2
  • 12
    • 0013228250 scopus 로고
    • Influence of body size on gaseous nitrogen elimination during high oxygen breathing
    • Cournand A, Yarmouth IG, Riley RL (1941) Influence of body size on gaseous nitrogen elimination during high oxygen breathing. Proc Soc Exp Biol 48: 280-284
    • (1941) Proc Soc Exp Biol , vol.48 , pp. 280-284
    • Cournand, A.1    Yarmouth, I.G.2    Riley, R.L.3
  • 14
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 15
    • 0002516206 scopus 로고
    • Standardized lung function testing: Report of working party "standardization of lung function tests"
    • Quanjer PH (1983) Standardized lung function testing: report of working party "standardization of lung function tests". Bull Eur Physiopathol Respir 19 (Suppl 5): 1-95
    • (1983) Bull Eur Physiopathol Respir , vol.19 , Issue.5 SUPPL. , pp. 1-95
    • Quanjer, P.H.1
  • 16
    • 0026656481 scopus 로고
    • Measurement of alveolar gas mixing in mechanically ventilated patients
    • Kox WJ, Mills CJ (1992) Measurement of alveolar gas mixing in mechanically ventilated patients. Crit Care Med 20: 924-927
    • (1992) Crit Care Med , vol.20 , pp. 924-927
    • Kox, W.J.1    Mills, C.J.2
  • 17
    • 0015437376 scopus 로고
    • 133xenon gas from the lungs: Comparison with nitrogen washout
    • 133xenon gas from the lungs: Comparison with nitrogen washout. Chest 62: 146-151
    • (1972) Chest , vol.62 , pp. 146-151
    • Guisan, M.1    Tisi, G.2    Ashburn, W.3    Moser, K.4
  • 18
    • 0020061288 scopus 로고
    • Alveolar gas mixing efficiency in the human lung
    • Cumming G, Guyatt R (1982) Alveolar gas mixing efficiency in the human lung. Clin Sci 62: 541-547
    • (1982) Clin Sci , vol.62 , pp. 541-547
    • Cumming, G.1    Guyatt, R.2
  • 19
    • 0021827111 scopus 로고
    • Measurement of functional residual capacity by sulfur hexafluoride washout
    • Jonmarker C, Jansson L, Jonson B, Larsson A, Werner O (1985) Measurement of functional residual capacity by sulfur hexafluoride washout. Anesthesiology 63: 89-95
    • (1985) Anesthesiology , vol.63 , pp. 89-95
    • Jonmarker, C.1    Jansson, L.2    Jonson, B.3    Larsson, A.4    Werner, O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.