메뉴 건너뛰기




Volumn 23, Issue 4, 1998, Pages 422-426

T2-weighted MR imaging for hepatic hemangiomas: Comparison of breath- hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil

Author keywords

Angioma, gastrointestinal tract; Liver neoplasms, MR; Liver, MR; Magnetic resonance (MR), comparative studies; Magnetic resonance (MR), technique

Indexed keywords

ADULT; ARTICLE; BREATH HOLDING; CLINICAL ARTICLE; DIAGNOSTIC VALUE; FEMALE; HUMAN; IMAGE ANALYSIS; INTERMETHOD COMPARISON; LIVER HEMANGIOMA; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 0031775932     PISSN: 09428925     EISSN: None     Source Type: Journal    
DOI: 10.1007/s002619900372     Document Type: Article
Times cited : (5)

References (19)
  • 1
    • 0028326868 scopus 로고
    • Cavernous hemangioma of the liver: Pathologic correlation with high-field MR imaging
    • Tung GA, Vaccaro JP, Cronan JJ, et al. Cavernous hemangioma of the liver: pathologic correlation with high-field MR imaging. AJR 1994;162:1113-1117
    • (1994) AJR , vol.162 , pp. 1113-1117
    • Tung, G.A.1    Vaccaro, J.P.2    Cronan, J.J.3
  • 2
    • 0027993463 scopus 로고
    • Hepatic hemangiomas: A multi-institutional study of appearance on T2-weighted and serial gadolinium-enhanced gradient-echo MR images
    • Semelka RC, Brown ED, Ascher SM, et al. Hepatic hemangiomas: a multi-institutional study of appearance on T2-weighted and serial gadolinium-enhanced gradient-echo MR images. Radiology 1994;192:401-406
    • (1994) Radiology , vol.192 , pp. 401-406
    • Semelka, R.C.1    Brown, E.D.2    Ascher, S.M.3
  • 3
    • 0024346020 scopus 로고
    • Giant cavernous hemangioma of the liver: CT and MR imaging in 10 cases
    • Choi BI, Han MC, Park JH, et al. Giant cavernous hemangioma of the liver: CT and MR imaging in 10 cases. AJR 1989;152:1221-1226
    • (1989) AJR , vol.152 , pp. 1221-1226
    • Choi, B.I.1    Han, M.C.2    Park, J.H.3
  • 4
    • 0025368642 scopus 로고
    • Small hepatocellular carcinoma versus small cavernous hemangioma: Differentiation with MR imaging at 2.0T
    • Choi BI, Han MC, Kim CW. Small hepatocellular carcinoma versus small cavernous hemangioma: differentiation with MR imaging at 2.0T. Radiology 1990;176:103-106
    • (1990) Radiology , vol.176 , pp. 103-106
    • Choi, B.I.1    Han, M.C.2    Kim, C.W.3
  • 5
    • 0023707788 scopus 로고
    • Distinction of hepatic cavernous hemangioma
    • Li KC, Glazer GM, Quint LE, et al. Distinction of hepatic cavernous hemangioma. Radiology 1988;169:409-415
    • (1988) Radiology , vol.169 , pp. 409-415
    • Li, K.C.1    Glazer, G.M.2    Quint, L.E.3
  • 6
    • 0025362350 scopus 로고
    • Differentiation between small hepatic hemangiomas and metastases on MR images: Importance of size-specific quantitative criteria
    • Iton K, Saini S, Hahn PF, et al. Differentiation between small hepatic hemangiomas and metastases on MR images: importance of size-specific quantitative criteria. AJR 1990;155:61-66
    • (1990) AJR , vol.155 , pp. 61-66
    • Iton, K.1    Saini, S.2    Hahn, P.F.3
  • 7
    • 0025310629 scopus 로고
    • Hepatic hemangiomas vs metastases: MR differentiation at 1.5T
    • Lombardo DM, Baker ME, Spritzer CE, et al. Hepatic hemangiomas vs metastases: MR differentiation at 1.5T. AJR 1990;155:55-59
    • (1990) AJR , vol.155 , pp. 55-59
    • Lombardo, D.M.1    Baker, M.E.2    Spritzer, C.E.3
  • 8
    • 0027508121 scopus 로고
    • Prospective comparison of T2-weighted fast spin-echo, with and without fat suppression, and conventional spin-echo pulse sequences in the upper abdomen
    • Schwarz LH, Seltzer SE, Tempany CMC, et al. Prospective comparison of T2-weighted fast spin-echo, with and without fat suppression, and conventional spin-echo pulse sequences in the upper abdomen. Radiology 1993;189:411-416
    • (1993) Radiology , vol.189 , pp. 411-416
    • Schwarz, L.H.1    Seltzer, S.E.2    Tempany, C.M.C.3
  • 9
    • 0027452674 scopus 로고
    • Abdominal MR imaging: Comparison of T2-eighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient-recalled imaging
    • Low RN, Francis IR, Sigeti JS, et al. Abdominal MR imaging: comparison of T2-eighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient-recalled imaging. Radiology 1993;186:803-811
    • (1993) Radiology , vol.186 , pp. 803-811
    • Low, R.N.1    Francis, I.R.2    Sigeti, J.S.3
  • 10
    • 0028001012 scopus 로고
    • Fast MR imaging of the liver: Quantitative comparison of techniques
    • Siewert B, Miiller MF, Foley M, et al. Fast MR imaging of the liver: quantitative comparison of techniques. Radiology 1994; 193:37-42
    • (1994) Radiology , vol.193 , pp. 37-42
    • Siewert, B.1    Miiller, M.F.2    Foley, M.3
  • 11
    • 0027957235 scopus 로고
    • Abdominal MR imaging: Evaluation of a fast spin-echo sequence
    • Outwater EK, Mitchell DG, Vinitski S. Abdominal MR imaging: evaluation of a fast spin-echo sequence. Radiology 1994; 190:425-429
    • (1994) Radiology , vol.190 , pp. 425-429
    • Outwater, E.K.1    Mitchell, D.G.2    Vinitski, S.3
  • 12
    • 0028055031 scopus 로고
    • T2-weighted MR imaging of the abdomen: Fast spin-echo versus conventional spin-echo sequences
    • Catasca JV, Mirowitz SA. T2-weighted MR imaging of the abdomen: fast spin-echo versus conventional spin-echo sequences. AJR 1994;162:61-67
    • (1994) AJR , vol.162 , pp. 61-67
    • Catasca, J.V.1    Mirowitz, S.A.2
  • 13
    • 0030183250 scopus 로고    scopus 로고
    • MRI in characterization of focal liver lesions: Comparison of T2-weighting by conventional spin-echo and turbo spin-echo sequences
    • Giovagnoni A, Paci E, Valeri G, et al. MRI in characterization of focal liver lesions: comparison of T2-weighting by conventional spin-echo and turbo spin-echo sequences. JMRI 1996;6:589-595
    • (1996) JMRI , vol.6 , pp. 589-595
    • Giovagnoni, A.1    Paci, E.2    Valeri, G.3
  • 14
    • 0028796848 scopus 로고
    • Comparison of breathhold fast spin-echo and conventional spin-echo pulse sequences for T2-weighted MR imaging of liver lesions
    • Rydberg JN, Lomas DJ, Coakley KJ, et al. Comparison of breathhold fast spin-echo and conventional spin-echo pulse sequences for T2-weighted MR imaging of liver lesions. Radiology 1995;194:431-437
    • (1995) Radiology , vol.194 , pp. 431-437
    • Rydberg, J.N.1    Lomas, D.J.2    Coakley, K.J.3
  • 15
    • 0029930953 scopus 로고    scopus 로고
    • Detection of focal hepatic lesions with MR imaging: Prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging
    • Soyer P, Givry SCD, Gueye C, et al. Detection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging. AJR 1996;166:1115-1121
    • (1996) AJR , vol.166 , pp. 1115-1121
    • Soyer, P.1    Givry, S.C.D.2    Gueye, C.3
  • 16
    • 0026612452 scopus 로고
    • Breath-hold T2-weighted sequences of the liver: A comparison of four techniques at 1.0 and 1.5T
    • Simm FC, Semelka RC, Recht M, et al. Breath-hold T2-weighted sequences of the liver: a comparison of four techniques at 1.0 and 1.5T. Magn Reson Imaging 1992;10:41-47
    • (1992) Magn Reson Imaging , vol.10 , pp. 41-47
    • Simm, F.C.1    Semelka, R.C.2    Recht, M.3
  • 17
    • 0029053234 scopus 로고
    • MR imaging of abdomen with a phased-array multicoil: Prospective clinical evaluation
    • Campeau NG, Johnson CD, Felmlee JP, et al. MR imaging of abdomen with a phased-array multicoil: prospective clinical evaluation. Radiology 1995;195:769-776
    • (1995) Radiology , vol.195 , pp. 769-776
    • Campeau, N.G.1    Johnson, C.D.2    Felmlee, J.P.3
  • 18
    • 0029972766 scopus 로고    scopus 로고
    • Intensity correction of phased-array surface coil images
    • Murakami JW, Hayes CE, Weinberger E. Intensity correction of phased-array surface coil images. MRM 1996;35:585-590
    • (1996) MRM , vol.35 , pp. 585-590
    • Murakami, J.W.1    Hayes, C.E.2    Weinberger, E.3
  • 19
    • 0031016816 scopus 로고    scopus 로고
    • Hepatic cavernous hemangioma: Appearance on T2-weighted fast spin-echo MR imaging with and without fat suppression
    • Soyer P, Dufresne AC, Somveille E, et al. Hepatic cavernous hemangioma: appearance on T2-weighted fast spin-echo MR imaging with and without fat suppression. AJR 1997;168:461-465
    • (1997) AJR , vol.168 , pp. 461-465
    • Soyer, P.1    Dufresne, A.C.2    Somveille, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.