메뉴 건너뛰기




Volumn 28, Issue 6, 1998, Pages 995-1005

Endovascular surgery based solely on noninvasive proprocedural imaging

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIOGRAPHY; ARTERY RECONSTRUCTION; ARTICLE; BYPASS SURGERY; DIAGNOSTIC IMAGING; ENDOVASCULAR SURGERY; HEALTH CARE COST; HUMAN; LEG ISCHEMIA; MAGNETIC RESONANCE ANGIOGRAPHY; MAJOR CLINICAL STUDY; PERIPHERAL VASCULAR DISEASE; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; VASCULAR SURGERY;

EID: 0031775531     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0741-5214(98)70025-4     Document Type: Article
Times cited : (45)

References (24)
  • 1
    • 0028234558 scopus 로고
    • Magnetic resonance angiography of the aorta, iliac, and femoral arteries
    • JP Carpenter RS Owen GA Holland Magnetic resonance angiography of the aorta, iliac, and femoral arteries Surgery 116 1994 17 23
    • (1994) Surgery , vol.116 , pp. 17-23
    • Carpenter, JP1    Owen, RS2    Holland, GA3
  • 2
    • 0031089438 scopus 로고    scopus 로고
    • Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels
    • M Gilfeather GA Holland ES Siegelman Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels Radiographics 17 1997 423 432
    • (1997) Radiographics , vol.17 , pp. 423-432
    • Gilfeather, M1    Holland, GA2    Siegelman, ES3
  • 3
    • 0026715592 scopus 로고
    • Magnetic resonance angiography of peripheral runoff vessels
    • JP Carpenter RS Owen RA Baum Magnetic resonance angiography of peripheral runoff vessels J Vasc Surg 16 1992 807 815
    • (1992) J Vasc Surg , vol.16 , pp. 807-815
    • Carpenter, JP1    Owen, RS2    Baum, RA3
  • 4
    • 0028575267 scopus 로고
    • Peripheral vascular surgery with magnetic resonance angiography as the sole preoperative imaging modality
    • JP Carpenter RA Baum GA Holland Peripheral vascular surgery with magnetic resonance angiography as the sole preoperative imaging modality J Vasc Surg 20 1994 861 871
    • (1994) J Vasc Surg , vol.20 , pp. 861-871
    • Carpenter, JP1    Baum, RA2    Holland, GA3
  • 5
    • 0027240903 scopus 로고
    • The potential for lower extremity revascularization without contrast arteriography: Experience with magnetic resonance angiography
    • RP Cambria EK Yucel DC Brewster The potential for lower extremity revascularization without contrast arteriography: Experience with magnetic resonance angiography J Vasc Surg 17 1993 1050 1057
    • (1993) J Vasc Surg , vol.17 , pp. 1050-1057
    • Cambria, RP1    Yucel, EK2    Brewster, DC3
  • 6
    • 0024549706 scopus 로고
    • Monitoring functional patency of in situ saphenous vein bypasses: The impact of a surveillance protocol and elective revision
    • DF Bandyk DD Schmitt GR Seabrook Monitoring functional patency of in situ saphenous vein bypasses: The impact of a surveillance protocol and elective revision J Vasc Surg 9 1989 286 296
    • (1989) J Vasc Surg , vol.9 , pp. 286-296
    • Bandyk, DF1    Schmitt, DD2    Seabrook, GR3
  • 7
    • 0027477122 scopus 로고
    • Impact of a color-flow duplex surveillance program on infrainguinal vein graft patency: A five-year experience
    • MM Idu JD Blankenstein P de Gier Impact of a color-flow duplex surveillance program on infrainguinal vein graft patency: A five-year experience J Vasc Surg 17 1993 42 53
    • (1993) J Vasc Surg , vol.17 , pp. 42-53
    • Idu, MM1    Blankenstein, JD2    de Gier, P3
  • 8
    • 0025158577 scopus 로고
    • The importance of routine surveillance of distal bypass grafts with duplex scanning: A study of 379 reversed vein grafts
    • JL Mills EJ Harris LM Taylor Jr The importance of routine surveillance of distal bypass grafts with duplex scanning: A study of 379 reversed vein grafts J Vasc Surg 12 1990 379 389
    • (1990) J Vasc Surg , vol.12 , pp. 379-389
    • Mills, JL1    Harris, EJ2    Taylor, LM3
  • 9
    • 0026577278 scopus 로고
    • Reversed vein graft stenosis: Early diagnosis and management
    • HD Berkowitz AD Fox DH. Deaton Reversed vein graft stenosis: Early diagnosis and management J Vasc Surg 15 1992 130 142
    • (1992) J Vasc Surg , vol.15 , pp. 130-142
    • Berkowitz, HD1    Fox, AD2    Deaton, DH.3
  • 10
    • 0031938733 scopus 로고    scopus 로고
    • Selective use of duplex ultrasound to replace preoperative arteriography for failing arterial vein grafts
    • KD Calligaro JR Syrek MJ Doughty Selective use of duplex ultrasound to replace preoperative arteriography for failing arterial vein grafts J Vasc Surg 27 1998 89 94
    • (1998) J Vasc Surg , vol.27 , pp. 89-94
    • Calligaro, KD1    Syrek, JR2    Doughty, MJ3
  • 11
    • 0024347916 scopus 로고
    • Color flow duplex screening of infrainguinal grafts combining low- and high-velocity criteria
    • JG Sladen JDS Reid PL. Cooperberg Color flow duplex screening of infrainguinal grafts combining low- and high-velocity criteria Am J Surg 158 1989 107 112
    • (1989) Am J Surg , vol.158 , pp. 107-112
    • Sladen, JG1    Reid, JDS2    Cooperberg, PL.3
  • 12
    • 84879282750 scopus 로고
    • Suggested standards for reports dealing with lower extremity ischemia
    • RB Rutherford DP Flanigan SK Gupta Suggested standards for reports dealing with lower extremity ischemia J Vasc Surg 4 1986 80 94
    • (1986) J Vasc Surg , vol.4 , pp. 80-94
    • Rutherford, RB1    Flanigan, DP2    Gupta, SK3
  • 13
    • 0026047075 scopus 로고
    • Standards for evaluating and reporting the results of surgical and percutaneous therapy of peripheral arterial disease
    • RB Rutherford GJ. Becker Standards for evaluating and reporting the results of surgical and percutaneous therapy of peripheral arterial disease Radiology 181 1991 277 281
    • (1991) Radiology , vol.181 , pp. 277-281
    • Rutherford, RB1    Becker, GJ.2
  • 14
    • 0031089438 scopus 로고    scopus 로고
    • Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels
    • M Gilfeather GA Holland ES Siegelman Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels Radiographics 17 1997 423 432
    • (1997) Radiographics , vol.17 , pp. 423-432
    • Gilfeather, M1    Holland, GA2    Siegelman, ES3
  • 15
    • 0029097288 scopus 로고
    • Noninvasive evaluation of the lower extremity arterial tree and graft surveillance
    • HS. Bassiouny Noninvasive evaluation of the lower extremity arterial tree and graft surveillance Surg Clin North Am 75 1995 593 606
    • (1995) Surg Clin North Am , vol.75 , pp. 593-606
    • Bassiouny, HS.1
  • 16
    • 0018965394 scopus 로고
    • Adverse reactions to contrast media: A report from the Committee on Safety of Contrast Media of the International Society of Radiology
    • WH Shehadi G. Toniolo Adverse reactions to contrast media: A report from the Committee on Safety of Contrast Media of the International Society of Radiology Radiology 137 1980 299 302
    • (1980) Radiology , vol.137 , pp. 299-302
    • Shehadi, WH1    Toniolo, G.2
  • 17
  • 18
    • 0026564750 scopus 로고
    • Arteriographic complications in the DSA era
    • JR Waugh N. Sacharias Arteriographic complications in the DSA era Radiology 182 1992 243 246
    • (1992) Radiology , vol.182 , pp. 243-246
    • Waugh, JR1    Sacharias, N.2
  • 19
    • 0027670723 scopus 로고
    • Magnetic resonance angiography of the pelvis and lower extremities
    • ML Schieber J Listerud RA Baum Magnetic resonance angiography of the pelvis and lower extremities Magn Reson Q 9 1993 152 187
    • (1993) Magn Reson Q , vol.9 , pp. 152-187
    • Schieber, ML1    Listerud, J2    Baum, RA3
  • 20
    • 0031950981 scopus 로고    scopus 로고
    • Cost-effectiveness of screening for asymptomatic carotid stenosis
    • D Yin JP. Carpenter Cost-effectiveness of screening for asymptomatic carotid stenosis J Vasc Surg 27 1998 245 255
    • (1998) J Vasc Surg , vol.27 , pp. 245-255
    • Yin, D1    Carpenter, JP.2
  • 21
    • 0028911430 scopus 로고
    • The cost-effectiveness of magnetic resonance angiography in cases of limb-threatening peripheral vascular disease
    • D Yin RA Baum JP Carpenter CP Langlotz MJ. Pentacost The cost-effectiveness of magnetic resonance angiography in cases of limb-threatening peripheral vascular disease Radiology 194 1995 757 764
    • (1995) Radiology , vol.194 , pp. 757-764
    • Yin, D1    Baum, RA2    Carpenter, JP3    Langlotz, CP4    Pentacost, MJ.5
  • 22
    • 0025978378 scopus 로고
    • The role of duplex scanning in the selection of patients for transluminal angioplasty
    • JM Edwards DM Coldwell ML Goldman The role of duplex scanning in the selection of patients for transluminal angioplasty J Vasc Surg 13 1991 69 74
    • (1991) J Vasc Surg , vol.13 , pp. 69-74
    • Edwards, JM1    Coldwell, DM2    Goldman, ML3
  • 23
    • 0025118041 scopus 로고
    • Can duplex scanning replace arteriography for lower extremity arterial disease?
    • TR Kohler G Andros JM Porter Can duplex scanning replace arteriography for lower extremity arterial disease? Ann Vasc Surg 4 1990 280 287
    • (1990) Ann Vasc Surg , vol.4 , pp. 280-287
    • Kohler, TR1    Andros, G2    Porter, JM3
  • 24
    • 0031009410 scopus 로고    scopus 로고
    • Grading carotid stenosis with ultrasound. An interlaboratory comparison
    • AV Alexandrov D Vital DS Brodie Grading carotid stenosis with ultrasound. An interlaboratory comparison Stroke 28 1997 1208 1210
    • (1997) Stroke , vol.28 , pp. 1208-1210
    • Alexandrov, AV1    Vital, D2    Brodie, DS3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.